ifcos-impl-mep
Use when modeling MEP (Mechanical, Electrical, Plumbing) systems in IFC -- HVAC, piping, electrical circuits, distribution elements, ports, and connections. Prevents the common mistake of not creating ports for flow connections between elements. Covers IfcSystem, IfcDistributionElement, flow segments, fittings, and MEP property sets. Keywords: MEP, HVAC, piping, electrical, IfcSystem, IfcDistributionElement, port, connection, flow segment, fitting, mechanical, plumbing, duct, ventilation, connect pipes.
- License 许可
- MIT
- 最近更新
- 2026-11-09
- Stars
- ★ 0
- Forks
- 0
01 前言 Front Matter
- name
- ifcos-impl-mep
- license
- MIT
- metadata
- { "author": "OpenAEC-Foundation", "version": "1.0" }
- description
- Use when modeling MEP (Mechanical, Electrical, Plumbing) systems in IFC -- HVAC, piping, electrical circuits, distribution elements, ports, and connections. Prevents the common mistake of not creating ports for flow connections between elements. Covers IfcSystem, IfcDistributionElement, flow segments, fittings, and MEP property sets. Keywords: MEP, HVAC, piping, electrical, IfcSystem, IfcDistributionElement, port, connection, flow segment, fitting, mechanical, plumbing, duct, ventilation, connect pipes.
- compatibility
- Designed for Claude Code. Requires IfcOpenShell Python library.
02 资源文件 3
- 参考文档references/anti-patterns.md11.8 KB
- 参考文档references/examples.md18.5 KB
- 参考文档references/methods.md9.7 KB
03 SKILL.md 正文
MEP System Implementation Guide
Quick Reference
Critical Warnings
- ALWAYS create ports on distribution elements BEFORE attempting to connect them. Elements without ports cannot participate in flow networks.
- ALWAYS create at least two ports per segment element (one inlet, one outlet). Segments are flow-through elements.
- NEVER connect two ports with the same flow direction. A
SOURCEport MUST connect to aSINKport. - NEVER use
IfcDistributionSystemin IFC2X3 models. Useifc_class="IfcSystem"for IFC2X3 compatibility. - ALWAYS use
ifcopenshell.api.run("system.add_system", ...)to create systems. NEVER usemodel.create_entity("IfcDistributionSystem")directly — it skips required relationship setup. - ALWAYS assign elements to a system AFTER creating port connections. The system is a logical grouping; ports define the physical topology.
- NEVER assume
system.remove_systemdeletes contained elements. It ONLY removes the system grouping; elements and their ports remain in the model. - ALWAYS use
ifcopenshell.api.run("root.create_entity", ...)for MEP elements, notmodel.create_entity(). The API sets GlobalId, ownership, and validates predefined types. - ALWAYS pass
productsas a list tosystem.assign_system(v0.8+ convention).
Decision Tree: MEP Workflow
Creating an MEP system?
├── Step 1: What IFC schema version?
│ ├── IFC2X3 → Use ifc_class="IfcSystem" for add_system
│ └── IFC4 / IFC4X3 → Use ifc_class="IfcDistributionSystem" (default)
│
├── Step 2: Create the system
│ └── system.add_system → system.edit_system (set Name + PredefinedType)
│
├── Step 3: Create distribution elements
│ ├── Duct/Pipe/Cable? → IfcDuctSegment, IfcPipeSegment, IfcCableSegment
│ ├── Elbow/Tee/Junction? → IfcDuctFitting, IfcPipeFitting, IfcCableFitting
│ ├── Air terminal/Fixture? → IfcAirTerminal, IfcSanitaryTerminal
│ ├── Valve/Damper/Switch? → IfcValve, IfcDamper, IfcSwitchingDevice
│ ├── Pump/Fan? → IfcPump, IfcFan
│ ├── Boiler/Chiller? → IfcBoiler, IfcChiller
│ └── Tank/Vessel? → IfcTank
│
├── Step 4: Create ports on each element
│ └── system.add_port (per connection point)
│
├── Step 5: Connect ports between elements
│ └── system.connect_port (port1, port2, direction)
│
├── Step 6: Assign elements to system
│ └── system.assign_system (products=[...], system=system)
│
├── Step 7: Assign flow controls (optional)
│ └── system.assign_flow_control (damper→duct, valve→pipe)
│
└── Step 8: Add properties and placement
├── pset.add_pset / pset.edit_pset (MEP property sets)
└── geometry (placement, representation)
Decision Tree: Which Distribution Element Class
What type of MEP element?
├── Carries flow (segments)?
│ ├── Air/gas → IfcDuctSegment
│ ├── Liquid → IfcPipeSegment
│ ├── Electrical → IfcCableSegment
│ └── Cable carrier → IfcCableCarrierSegment
│
├── Changes direction/splits (fittings)?
│ ├── Air/gas → IfcDuctFitting
│ ├── Liquid → IfcPipeFitting
│ ├── Electrical → IfcCableFitting
│ └── Cable carrier → IfcCableCarrierFitting
│
├── End point (terminals)?
│ ├── Air supply/return → IfcAirTerminal
│ ├── Plumbing fixture → IfcSanitaryTerminal
│ ├── Electrical outlet → IfcOutlet
│ ├── Light fixture → IfcLightFixture
│ ├── Fire sprinkler → IfcFireSuppressionTerminal
│ └── Communication jack → IfcCommunicationsAppliance
│
├── Controls flow (controllers)?
│ ├── Airflow → IfcDamper
│ ├── Liquid flow → IfcValve
│ ├── Electrical → IfcSwitchingDevice / IfcProtectiveDevice
│ └── Flow meter → IfcFlowMeter
│
├── Moves medium (movers)?
│ ├── Air → IfcFan
│ ├── Liquid → IfcPump
│ └── Gas → IfcCompressor
│
├── Converts energy?
│ ├── Heating → IfcBoiler
│ ├── Cooling → IfcChiller
│ ├── Heat exchange → IfcHeatExchanger
│ ├── Cooling tower → IfcCoolingTower
│ ├── Air handling → IfcAirToAirHeatRecovery / IfcUnitaryEquipment
│ └── Electrical → IfcTransformer / IfcElectricGenerator
│
├── Stores medium?
│ ├── Liquid → IfcTank
│ └── Electrical → IfcElectricFlowStorageDevice
│
├── Treats medium?
│ ├── Air filter → IfcFilter
│ └── Grease/oil trap → IfcInterceptor
│
└── Senses/monitors (control elements)?
├── Temperature → IfcSensor (TEMPERATURESENSOR)
├── Pressure → IfcSensor (PRESSURESENSOR)
├── Flow rate → IfcSensor (FLOWSENSOR)
├── Smoke → IfcSensor (SMOKESENSOR)
└── Actuator → IfcActuator
Essential Patterns
Pattern 1: Complete HVAC System (IFC4)
# IFC4 / IFC4X3
import ifcopenshell
import ifcopenshell.api
model = ifcopenshell.api.run("project.create_file", version="IFC4")
# Bootstrap (project, units, contexts, spatial hierarchy)
project = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcProject", name="MEP Project")
ifcopenshell.api.run("unit.assign_unit", model)
model3d = ifcopenshell.api.run("context.add_context", model, context_type="Model")
body = ifcopenshell.api.run("context.add_context", model,
context_type="Model", context_identifier="Body",
target_view="MODEL_VIEW", parent=model3d)
site = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcSite", name="Site")
building = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcBuilding", name="Building A")
storey = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcBuildingStorey", name="Level 1")
ifcopenshell.api.run("aggregate.assign_object", model,
products=[site], relating_object=project)
ifcopenshell.api.run("aggregate.assign_object", model,
products=[building], relating_object=site)
ifcopenshell.api.run("aggregate.assign_object", model,
products=[storey], relating_object=building)
# Step 1: Create distribution system
hvac = ifcopenshell.api.run("system.add_system", model,
ifc_class="IfcDistributionSystem")
ifcopenshell.api.run("system.edit_system", model,
system=hvac,
attributes={"Name": "Supply Air System", "PredefinedType": "VENTILATION"})
# Step 2: Create elements
ahu = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcUnitaryEquipment", name="AHU-01")
duct1 = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcDuctSegment", name="SD-01")
duct2 = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcDuctSegment", name="SD-02")
terminal = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcAirTerminal", name="AT-01")
# Step 3: Place in spatial structure
ifcopenshell.api.run("spatial.assign_container", model,
products=[ahu, duct1, duct2, terminal], relating_structure=storey)
# Step 4: Create ports (inlet + outlet per segment)
ahu_out = ifcopenshell.api.run("system.add_port", model, element=ahu)
d1_in = ifcopenshell.api.run("system.add_port", model, element=duct1)
d1_out = ifcopenshell.api.run("system.add_port", model, element=duct1)
d2_in = ifcopenshell.api.run("system.add_port", model, element=duct2)
d2_out = ifcopenshell.api.run("system.add_port", model, element=duct2)
term_in = ifcopenshell.api.run("system.add_port", model, element=terminal)
# Step 5: Connect ports (AHU → Duct1 → Duct2 → Terminal)
ifcopenshell.api.run("system.connect_port", model,
port1=ahu_out, port2=d1_in, direction="SOURCE")
ifcopenshell.api.run("system.connect_port", model,
port1=d1_out, port2=d2_in, direction="SOURCE")
ifcopenshell.api.run("system.connect_port", model,
port1=d2_out, port2=term_in, direction="SOURCE")
# Step 6: Assign all elements to the system
ifcopenshell.api.run("system.assign_system", model,
products=[ahu, duct1, duct2, terminal], system=hvac)
Pattern 2: Piping Network with Fittings
# IFC4 / IFC4X3: requires completed bootstrap
# Create plumbing system
plumbing = ifcopenshell.api.run("system.add_system", model,
ifc_class="IfcDistributionSystem")
ifcopenshell.api.run("system.edit_system", model,
system=plumbing,
attributes={"Name": "Hot Water Supply", "PredefinedType": "DOMESTICHOTWATER"})
# Create pipe elements
pipe1 = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcPipeSegment", name="HWS-P01")
elbow = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcPipeFitting", name="HWS-E01")
pipe2 = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcPipeSegment", name="HWS-P02")
valve = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcValve", name="HWS-V01")
# Ports: pipes need 2, fittings need 2+, terminals need 1
p1_in = ifcopenshell.api.run("system.add_port", model, element=pipe1)
p1_out = ifcopenshell.api.run("system.add_port", model, element=pipe1)
elb_in = ifcopenshell.api.run("system.add_port", model, element=elbow)
elb_out = ifcopenshell.api.run("system.add_port", model, element=elbow)
p2_in = ifcopenshell.api.run("system.add_port", model, element=pipe2)
p2_out = ifcopenshell.api.run("system.add_port", model, element=pipe2)
# Connect: Pipe1 → Elbow → Pipe2
ifcopenshell.api.run("system.connect_port", model,
port1=p1_out, port2=elb_in, direction="SOURCE")
ifcopenshell.api.run("system.connect_port", model,
port1=elb_out, port2=p2_in, direction="SOURCE")
# Assign flow control (valve controls pipe)
ifcopenshell.api.run("system.assign_flow_control", model,
relating_flow_element=pipe1, related_flow_control=valve)
# Assign to system
ifcopenshell.api.run("system.assign_system", model,
products=[pipe1, elbow, pipe2, valve], system=plumbing)
Pattern 3: Tee Fitting (3 Ports)
# IFC4 / IFC4X3
tee = ifcopenshell.api.run("root.create_entity", model,
ifc_class="IfcPipeFitting", name="HWS-T01")
# Tee fittings have 3 ports: inlet, outlet-main, outlet-branch
tee_in = ifcopenshell.api.run("system.add_port", model, element=tee)
tee_out1 = ifcopenshell.api.run("system.add_port", model, element=tee)
tee_out2 = ifcopenshell.api.run("system.add_port", model, element=tee)
# Connect: upstream pipe → tee inlet
# tee outlet1 → downstream main
# tee outlet2 → downstream branch
ifcopenshell.api.run("system.connect_port", model,
port1=upstream_pipe_out, port2=tee_in, direction="SOURCE")
ifcopenshell.api.run("system.connect_port", model,
port1=tee_out1, port2=main_pipe_in, direction="SOURCE")
ifcopenshell.api.run("system.connect_port", model,
port1=tee_out2, port2=branch_pipe_in, direction="SOURCE")
Pattern 4: IFC2X3 System (Backward Compatible)
# IFC2X3: use IfcSystem instead of IfcDistributionSystem
model = ifcopenshell.api.run("project.create_file", version="IFC2X3")
# ... bootstrap ...
system = ifcopenshell.api.run("system.add_system", model,
ifc_class="IfcSystem") # REQUIRED for IFC2X3
ifcopenshell.api.run("system.edit_system", model,
system=system,
attributes={"Name": "Heating System"})
# NOTE: PredefinedType is NOT available on IfcSystem in IFC2X3.
# Use ObjectType attribute for classification instead.
ifcopenshell.api.run("attribute.edit_attributes", model,
product=system,
attributes={"ObjectType": "HEATING"})
Distribution System Types (IFC4 / IFC4X3)
Set via PredefinedType attribute on IfcDistributionSystem:
| PredefinedType | Domain | Description |
|---|---|---|
VENTILATION |
HVAC | Supply/return/exhaust air systems |
HEATING |
HVAC | Hot water heating, radiator circuits |
COOLING |
HVAC | Chilled water, refrigerant loops |
AIRCONDITIONING |
HVAC | Combined heating/cooling air systems |
EXHAUST |
HVAC | Kitchen/fume exhaust systems |
DOMESTICHOTWATER |
Plumbing | Hot water supply |
DOMESTICCOLDWATER |
Plumbing | Cold water supply |
DRAINAGE |
Plumbing | Gravity drainage, waste water |
WASTEWATER |
Plumbing | Waste water systems |
STORMWATER |
Plumbing | Rainwater drainage |
SEWAGE |
Plumbing | Sewer connections |
RAINWATER |
Plumbing | Rainwater collection |
ELECTRICAL |
Electrical | Power distribution |
LIGHTING |
Electrical | Lighting circuits |
POWERGENERATION |
Electrical | On-site power generation |
LIGHTNINGPROTECTION |
Electrical | Lightning protection systems |
EARTHING |
Electrical | Grounding/earthing |
FIREPROTECTION |
Fire | Sprinklers, fire suppression |
SECURITY |
Security | Access control, CCTV |
COMMUNICATION |
Comms | Data/telephone networks |
DATA |
Comms | Data networks |
TV |
Comms | Television distribution |
SIGNAL |
Controls | Signal/control systems |
CONTROL |
Controls | Building automation |
GAS |
Fuel | Natural gas distribution |
FUEL |
Fuel | Fuel supply systems |
COMPRESSEDAIR |
Pneumatic | Compressed air distribution |
VACUUM |
Pneumatic | Vacuum systems |
REFRIGERATION |
HVAC | Refrigeration systems |
CHILLEDWATER |
HVAC | Chilled water distribution |
CONDENSERWATER |
HVAC | Condenser water loops |
CHEMICAL |
Process | Chemical distribution |
DISPOSAL |
Waste | Waste disposal systems |
HAZARDOUS |
Safety | Hazardous material systems |
CONVEYING |
Transport | Material conveying |
USERDEFINED |
Custom | Set ObjectType attribute |
NOTDEFINED |
Default | Unspecified |
Port Flow Directions
| Direction | Meaning | When to Use |
|---|---|---|
SOURCE |
Flow exits through this port | Outlet ports, downstream direction |
SINK |
Flow enters through this port | Inlet ports, upstream direction |
SOURCEANDSINK |
Bidirectional flow | Reversible systems, heat exchangers |
NOTDEFINED |
Direction not specified | When flow direction is unknown |
Rule: When connecting two ports, direction on connect_port describes the relationship from port1's perspective. If port1 is a SOURCE, flow goes from port1 to port2.
System Traversal (ifcopenshell.util.system)
# IFC4 / IFC4X3
import ifcopenshell.util.system
# Get all elements in a system
elements = ifcopenshell.util.system.get_system_elements(hvac)
# Get all systems an element belongs to
systems = ifcopenshell.util.system.get_element_systems(duct1)
# Get ports on an element (optionally filter by direction)
all_ports = ifcopenshell.util.system.get_ports(duct1)
outlets = ifcopenshell.util.system.get_ports(duct1, flow_direction="SOURCE")
inlets = ifcopenshell.util.system.get_ports(duct1, flow_direction="SINK")
# Traverse connections: downstream / upstream
downstream = ifcopenshell.util.system.get_connected_to(duct1)
upstream = ifcopenshell.util.system.get_connected_from(duct1)
# Get element that owns a port
owner = ifcopenshell.util.system.get_port_element(d1_out)
# Get port connected to a given port
partner = ifcopenshell.util.system.get_connected_port(d1_out)
MEP Property Sets
Standard Property Sets for Distribution Elements
# IFC4 / IFC4X3: Add MEP-specific properties
# Duct segment properties
pset = ifcopenshell.api.run("pset.add_pset", model,
product=duct1, name="Pset_DuctSegmentTypeCommon")
ifcopenshell.api.run("pset.edit_pset", model, pset=pset, properties={
"NominalDiameter": 0.315, # meters
"InnerDiameter": 0.313,
"OuterDiameter": 0.315,
"Length": 3.0,
})
# Pipe segment properties
pset_pipe = ifcopenshell.api.run("pset.add_pset", model,
product=pipe1, name="Pset_PipeSegmentTypeCommon")
ifcopenshell.api.run("pset.edit_pset", model, pset=pset_pipe, properties={
"NominalDiameter": 0.025,
"InnerDiameter": 0.021,
"OuterDiameter": 0.025,
"WorkingPressure": 600000.0, # Pascals
"FlowRateRange": "0.1 - 0.5", # m3/s
})
# Quantity set for a duct
qto = ifcopenshell.api.run("pset.add_qto", model,
product=duct1, name="Qto_DuctSegmentBaseQuantities")
ifcopenshell.api.run("pset.edit_qto", model, qto=qto, properties={
"Length": 3.0,
"GrossCrossSectionArea": 0.078,
"OuterSurfaceArea": 2.97,
})
Common MEP Pset Names
| Element Type | Property Set | Key Properties |
|---|---|---|
| Duct segments | Pset_DuctSegmentTypeCommon |
NominalDiameter, Length |
| Pipe segments | Pset_PipeSegmentTypeCommon |
NominalDiameter, WorkingPressure |
| Air terminals | Pset_AirTerminalTypeCommon |
AirFlowRateRange, NominalAirFlowRate |
| Valves | Pset_ValveTypeCommon |
ValvePattern, WorkingPressure |
| Pumps | Pset_PumpTypeCommon |
FlowRateRange, NominalRotationSpeed |
| Fans | Pset_FanTypeCommon |
NominalAirFlowRate, NominalTotalPressure |
| Boilers | Pset_BoilerTypeCommon |
NominalEnergyConsumption, WaterTemperatureRange |
Version Differences
| Feature | IFC2X3 | IFC4 | IFC4X3 |
|---|---|---|---|
| System class | IfcSystem |
IfcDistributionSystem |
IfcDistributionSystem |
| PredefinedType on system | Not available | Full enum (37 values) | Full enum + additions |
| Building system | Not available | IfcBuildingSystem |
IfcBuildingSystem |
| Port nesting | IfcRelNests |
IfcRelNests |
IfcRelNests |
| Port connection | IfcRelConnectsPorts |
IfcRelConnectsPorts |
IfcRelConnectsPorts |
| Flow direction enum | Same | Same | Same |
Version-Safe Pattern
# Detect schema and choose correct system class
schema = model.schema
if schema == "IFC2X3":
system = ifcopenshell.api.run("system.add_system", model,
ifc_class="IfcSystem")
else:
system = ifcopenshell.api.run("system.add_system", model,
ifc_class="IfcDistributionSystem")
Dependency
This skill depends on:
- ifcos-syntax-api for
api.run()invocation patterns, module table, and parameter conventions - ifcos-syntax-fileio for file creation, writing, and transaction management
Reference Links
- API Method Signatures -- Complete signatures for all 12 system API functions
- Working Code Examples -- End-to-end MEP system examples
- Anti-Patterns -- Common MEP modeling mistakes and how to avoid them
Official Sources
04 同仓库更多 Skills
manimce-best-practices
Trigger when: (1) User mentions "manim" or "Manim Community" or "ManimCE", (2) Code contains `from manim import *`, (3) User runs `manim` CLI commands, (4) Working with Scene, MathTex, Create(), or ManimCE-specific classes. Best practices for Manim Community Edition - the community-maintained Python animation engine. Covers Scene structure, animations, LaTeX/MathTex, 3D with ThreeDScene, camera control, styling, and CLI usage. NOT for ManimGL/3b1b version (which uses `manimlib` imports and `manimgl` CLI).
drawio
Create, edit, replicate, import, and export draw.io diagrams with an offline YAML-first workflow: architecture, network topologies, flowcharts, UML/ER, org charts, Mermaid/CSV conversion, existing .drawio bundles, style presets, themes, and non-publication formula diagrams. For publication figures (paper, thesis, IEEE, camera-ready) use drawio-academic-skills instead.
drawio-academic-skills
Publication-figure overlay for draw.io. Use instead of drawio whenever the diagram is for a paper, thesis, dissertation, journal, conference, IEEE/ACM submission, manuscript, camera-ready, Word/LaTeX figure, or other publication. Applies venue, figure-type, color, caption/legend, formula, and paper-readability gates for architecture, workflow, roadmap, network-topology, and replicated paper figures.
uncertainty-and-units
Tracks physical units and propagates measurement uncertainty in scientific calculations using pint and uncertainties. Use for unit conversion and dimensional checking, GUM uncertainty budgets, Type A and Type B evaluation, coverage factors and expanded uncertainty, Monte Carlo propagation, significant-figure and plus-minus reporting, error propagation through curve fits, CODATA constants, auditing Python code for stripped units or broken uncertainty propagation, and order-of-magnitude plausibility checks using dimensionless groups (Reynolds, Peclet, Damkohler, Knudsen, Biot, Womersley), characteristic scales such as diffusion time or Debye length, and observed magnitude ranges. Trigger on "is this number physically reasonable", "sanity check these units", "what regime is this flow in", or a result that looks off by orders of magnitude.
statistical-analysis
Guided statistical analysis for research data - test selection, assumption checking, effect sizes, power analysis, Bayesian alternatives, and APA-formatted reporting. Use whenever a user wants to compare groups, test a hypothesis, analyze experimental or survey data, check statistical assumptions, compute required sample sizes, or write up results - even if they never name a specific test. Covers t-tests, ANOVA, chi-square, correlation, regression, non-parametric and Bayesian methods. For low-level model APIs, see the statsmodels and pymc skills.
simpy
Builds, inspects, tests, and analyzes bounded process-based discrete-event simulations with SimPy. Use for event scheduling, resource queues, interrupts, monitoring, independent replications, warm-up, and reproducible output analysis.