Progressive-disclosure workflow for PowerWorld Simulator studies through PowerMCP. Use whenever the user wants to open a PowerWorld case, solve the base power flow, inspect flows or voltages, change model data, run contingency analysis, or pull sensitivity matrices (PTDF, LODF, Jacobian, Ybus) — eve

License 许可
MIT
最近更新
2026-11-09
Stars
★ 0
Forks
0

01 前言 Front Matter

name
powerworld
risk
low
source
https://github.com/Power-Agent/PowerSkills
license
MIT
version
1.0.0
category
electrical-engineering
description
Progressive-disclosure workflow for PowerWorld Simulator studies through PowerMCP. Use whenever the user wants to open a PowerWorld case, solve the base power flow, inspect flows or voltages, change model data, run contingency analysis, or pull sensitivity matrices (PTDF, LODF, Jacobian, Ybus) — eve
imported_at
2026-09-20
source_path
powerskills-tool/skills/powerworld/SKILL.md
source_repository
Power-Agent/PowerSkills
disable-model-invocation
false

03 SKILL.md 正文

PowerWorld workflow

Expose PowerWorld tools in stages. Start with the base case. Move to contingencies or matrix analytics only after the operating condition is understood.

Default tool ladder

  1. open_case(case_path)
  2. run_powerflow(solution_method)
  3. get_power_flow_results(object_type, additional_fields) and get_key_field_list(object_type)
  4. change_and_confirm_params(...) or change_parameters_multiple_element(...)
  5. analyze_contingencies(option, validate)
  6. get_ybus(), get_jacobian(), get_lodf_matrix(), get_ptdf_matrix_fast(), to_graph(), determine_shortest_path(), or run_robustness_analysis()

Working rules

  • Do not run contingencies before the base case solves cleanly.
  • Ask for the monitored objects, limits, and fields before large result pulls.
  • Use sensitivities or graph tools to rank candidate fixes before applying bulk changes.
  • Confirm every model change by re-solving and checking the same monitored quantities.

Escalation triggers

Quote the bus or branch and the value that tripped each row rather than saying "violations exist".

Observation Escalate to
Bus voltage outside [0.95, 1.05] pu in the power-flow results voltage-violation-mitigation
Branch percent loading > 100 thermal-overload-mitigation
analyze_contingencies returns binding violations contingency-mitigation
run_powerflow fails to converge convergence-failure-mitigation

Deliver

  • The case, base-case status, and monitored findings.
  • Any changes applied and their effect.
  • Whether an advanced study or mitigation playbook is required next.