AGENT SKILL

absorption-stripping-design

Apply the Kremser absorption/stripping factor method for dilute systems and packed/tray column HETP / efficiency screening. Use when sizing an absorber or stripper, estimating per-stage performance for a dilute solute, or sanity-checking a vendor sizing. Don't use for reactive absorption with chemical equilibrium (use sour-gas-amine-treating), highly concentrated systems (Kremser assumes dilute), or rate-based packed-column design with detailed mass-transfer correlations.

License 许可
MIT
最近更新
2026-11-09
Stars
★ 0
Forks
0

01 前言 Front Matter

name
absorption-stripping-design
source
https://github.com/jskherman/engg-skills
license
MIT
version
1.0.0
metadata
{ "hermes": { "tags": [ "chemical-engineering", "process-engineering", "separations", "absorption", "stripping", "design" ], "category": "separations" } }
description
Apply the Kremser absorption/stripping factor method for dilute systems and packed/tray column HETP / efficiency screening. Use when sizing an absorber or stripper, estimating per-stage performance for a dilute solute, or sanity-checking a vendor sizing. Don't use for reactive absorption with chemical equilibrium (use sour-gas-amine-treating), highly concentrated systems (Kremser assumes dilute), or rate-based packed-column design with detailed mass-transfer correlations.
imported_at
2026-09-20
source_path
skills/absorption-stripping-design/SKILL.md
compatibility
Compatible with Agent Skills clients and Hermes Agent; Python 3.11+ and uv are required for bundled Python scripts.
source_repository
jskherman/engg-skills

02 资源文件 2

03 SKILL.md 正文

Absorption and Stripping Shortcut Design

Overview

Implements the Kremser equation and helpers for stage counting in dilute absorber/stripper systems. The Kremser formulation is exact for systems with constant absorption factor A = L / (K V) and a linear equilibrium relationship y* = K x.

For concentrated systems, reactive absorbers, or rate-based design, use a rigorous simulator or rate-based correlation; this skill is screening only.

Prerequisites

  1. uv available.
  2. On first use the script writes LICENSE_NOTIFICATION.txt.

When to Use

  • Sizing a dilute absorber (lean oil, glycol dehydrator screening, dilute acid-gas scrubber).
  • Estimating the stripping factor and stage count for a desorber.
  • Cross-checking vendor sizing for a tray or packed column.

Don't use for

  • Reactive absorption with chemical equilibrium (DEA/MDEA + acid gas): use sour-gas-amine-treating for screening or a rate-based simulator.
  • Concentrated solute (mole fraction > 5-10%): Kremser breaks down.
  • Detailed packing-specific design: use vendor correlations or a rate-based simulator.

Utility Scripts

  • uv run scripts/kremser.py --N 8 --A 1.4 --K 0.5 --y-in 0.02 --x-in 0.0 --output /tmp/kremser.json
  • uv run scripts/kremser.py --N 8 --A 0.8 --K 0.5 --y-in 0.02 --x-in 0.0 --output /tmp/stripper.json

Procedure

  1. Decide on solute, lean-solvent K-value at column conditions (often evaluated at a representative T).
  2. Pick a target removal fraction (e.g. 95% of solute absorbed).
  3. Compute the required absorption factor A = L / (K V); aim for A = 1.2 - 1.5 (industry rule of thumb for non-reactive dilute systems).
  4. Solve Kremser for N stages.
  5. Convert equilibrium stages to actual stages with a Murphree efficiency (~0.5 - 0.8 for trays; for packed beds, divide column height by HETP).
  6. Sanity-check operating line vs equilibrium line: lines must not cross.

Pitfalls

  • Using Kremser for a reactive absorber. The acid-gas + amine system needs a different framework.
  • Picking A = 1.0 (or just slightly above) and reporting it as feasible; it implies infinite stages at the limit.
  • Using a single K for the whole column when K varies strongly with T or composition. Average it with care.
  • Confusing absorption factor A = L/(KV) with stripping factor S = K V/L.
  • Reporting equilibrium stages as actual trays without applying efficiency.
  • Forgetting to verify that the operating line and equilibrium line do not cross within the column (a sign that the requested removal is infeasible at the chosen A).
  • Picking L/G from the gas mass balance only — heat balance and rich solvent loading change the effective L.
  • Using Kremser for solute mole fractions > 5-10%; non-linear equilibrium invalidates the constant-A assumption.

Fallback Strategies

  • For reactive absorption, switch to sour-gas-amine-treating (screening) or a rate-based simulator (ProMax, ProTreat, Aspen rate-based).
  • For high-concentration systems, do a manual stage-by-stage operating / equilibrium analysis on a y-x diagram with varying K.

Verification

  • Run the listed script with representative inputs and an --output file when a deterministic calculation is available.
  • Confirm the JSON result contains ok: true, expected units, and no unhandled warnings.
  • Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.

References

  • references/kremser_derivation.md — derivation and assumptions.
  • Treybal, Mass-Transfer Operations.
  • Sinnott, Coulson & Richardson, Volume 6.

Anti-Patterns

  • Reporting "5 actual trays" without specifying Murphree efficiency.
  • Picking A from the recommended range without justifying it from capex/opex trade-off.
  • Mixing up "absorption factor" with "absorption efficiency".