Overview
Groundwater is the world's largest accessible freshwater store and its least visible — models make it legible. This skill covers aquifer conceptualization, parameter estimation (pumping tests, slug tests), building and calibrating flow models (MODFLOW 6), solute transport basics, and the decision-support products (capture zones, drawdown forecasts, sustainable yield) that models exist to produce.
When to use
- Designing a water-supply wellfield: sustainable pumping rates and well interference
- Delineating wellhead protection areas and contaminant capture zones
- Predicting drawdown, dewatering, or impacts of new abstractions
- Modeling contaminant plume migration and remediation scenarios
- Reviewing a groundwater study for regulatory or legal purposes
Core concepts
-
Darcy's law: q = −K∇h — specific discharge proportional to hydraulic gradient; K (hydraulic conductivity) spans 10+ orders of magnitude across materials — the single most important and uncertain parameter.
-
Storage: confined aquifers release water from compressibility (storativity S ~10⁻⁵–10⁻³); unconfined from draining pores (specific yield Sy ~0.05–0.3) — transient responses differ by orders of magnitude.
-
Theis and Cooper–Jacob: pumping-test analysis giving T (transmissivity) and S from drawdown vs time; diagnostic plots (derivative) reveal boundaries, leakage, and dual-porosity before fitting.
-
Conceptual model first: hydrostratigraphy, recharge, boundaries (no-flow, constant-head, rivers), stresses — the numerical model only computes what the conceptual model asserts; most bad models are bad conceptualizations.
-
Calibration: history matching heads and fluxes; non-uniqueness is fundamental (different K fields, same heads) — regularize with pilot points or zones, and keep parameters within physically plausible ranges.
-
Transport: advection–dispersion equation; retardation (sorption), decay, and matrix diffusion control plume fate — dispersivity is scale-dependent and the most abused parameter in transport modeling.
-
Capture vs safe yield: pumping intercepts natural discharge and induces recharge — "safe yield" is about acceptable impacts on streams, wetlands, and neighbors, not a recharge number; Theis's capture principle is the correct framing.
-
Density-dependent flow: seawater intrusion and deep brines need variable-density codes (SEAWAT) — constant-density models misplace the freshwater–saltwater interface, sometimes badly.
-
Fractured-rock duality: matrix stores, fractures transmit — equivalent-porous-medium models fail where fracture networks dominate; discrete-fracture or dual-porosity approaches are needed, with field data to constrain them.
Practical workflow
1. Build the conceptual model
- Compile geology (borehole logs, geophysics), water levels (contour the potentiometric surface — flow is perpendicular to contours), recharge estimates (water-table fluctuation, chloride mass balance), and all abstractions.
- Define model domain, layers, and boundary conditions from the hydrogeology — not from software convenience; boundaries far enough to not dictate the answer.
- List the decisions the model must support (pumping rate? plume arrival time?) — this sets the required accuracy and complexity.
2. Parameterize from field data
- Analyze pumping tests with diagnostic derivative plots before curve-fitting; report T, S with the method and its assumptions (Theis assumes confined, infinite, homogeneous).
- Slug tests for K at individual wells (cheap, small support volume); grain-size estimates only as rough priors.
- Recharge from multiple methods (they disagree — the spread is your uncertainty); river/aquifer exchange from streambed measurements or baseflow separation.
3. Build, calibrate, verify (MODFLOW 6)
- Discretize: grid refined near wells/rivers/gradients; check water-balance error (<1%) — a model that doesn't conserve mass is broken.
- Calibrate to heads AND fluxes (stream gains/losses, spring flows) — heads alone underconstrain K massively.
- Validate on an independent period (different pumping regime); a model that only matches its calibration period is a fitted curve.
- Sensitivity analysis: identify which parameters actually control the decision variable — refine those, fix the rest.
4. Deliver decision products
- Capture zones: backward particle tracking (MODPATH) for wellhead protection — use probabilistic zones reflecting K uncertainty, not a single deterministic line.
- Drawdown forecasts: scenario ensembles (pumping × recharge × parameter uncertainty), not one run.
- Sustainable yield: frame as capture (reduced discharge + induced recharge), not "recharge equals safe pumping" — pumping always intercepts natural discharge eventually.
- Document everything: conceptual model, parameters with sources, calibration metrics, limitations — a regulator should be able to reproduce it.
5. Model seawater intrusion for a coastal aquifer
- Characterize the wedge: multi-level salinity monitoring perpendicular to the coast — one well screen gives one point, not a wedge.
- Build a variable-density model (SEAWAT); calibrate to the salinity distribution and its movement over time, not just heads.
- Test management scenarios: reduced pumping, relocation of wells inland, injection barriers — and show the timescale: wedges advance and retreat over decades, not months.
6. Quick-reference checklist
- [ ] Conceptual model built and documented before any numerics
- [ ] Water-balance error <1% (mass conservation verified)
- [ ] Calibrated to heads AND fluxes (streams, springs)
- [ ] Parameters kept within physically plausible ranges
- [ ] Validated on an independent period/regime
- [ ] Sensitivity analysis identifies decision-controlling parameters
- [ ] Capture zones presented probabilistically, not as single lines
- [ ] Sustainable yield framed as capture impacts, not "recharge = safe pumping"
Common pitfalls
- Conceptual errors: wrong aquifer geometry or boundary conditions — no amount of calibration fixes a model of the wrong system.
- Heads-only calibration: matching water levels while missing streamflows by 10× — calibrate to fluxes too.
- Overparameterization: more K zones than data can support — regularize and keep parameters plausible.
- Dispersivity abuse: calibrating dispersivity to fit a plume, then using it predictively at a different scale — it's scale-dependent.
- Steady-state complacency: calibrating steady-state then predicting transients (or vice versa) without testing both.
- Deterministic capture zones: a single particle-track line ignores K uncertainty — protection areas need probabilistic treatment.
- "Safe yield = recharge": the classic fallacy — sustainable pumping is about acceptable capture impacts, not a recharge number.
- Constant-density modeling of coastal aquifers: the Ghyben–Herzberg sharp-interface guess inside a constant-density model — use variable-density physics or state the approximation's limits loudly.
- Boundary conditions that manufacture water: constant-head boundaries placed too close act as infinite sources, masking drawdown — extend the domain or use head-dependent boundaries.
04 同仓库更多 Skills
web-scrape
Turn web pages into LLM-ready markdown via the Firecrawl API (renders JS, anti-bot handling). Use when browser_open/fetch fails on JS-heavy pages, or when you need clean markdown/structured extraction from a site. Requires FIRECRAWL_API_KEY.
design-taste-frontend
tasteskill v2, the anti-slop frontend skill. Art direction for websites, distilled from a study of 247 curated gallery sites (One Page Love, Awwwards Sites of the Day). Deals researched directions (idea, composition, type, palette, photographs, section blueprints) from a library, enforces a strict no-slop house style with a real-browser inspector, and runs a look-and-fix loop on screenshots. Use this whenever you build, design, redesign, restyle, polish or review a landing page, marketing site, portfolio, product page, one-pager, hero or any public-facing web page, in any stack (HTML/CSS, React, Next.js, Vue, Svelte, Astro, Tailwind) — also when the user says a page looks generic, templated, "AI-made", sloppy, or asks to make it look designed, premium, award-level or less like every other site. Not for dashboards or app screens.
test-driven-development
Use when implementing any feature or bugfix, before writing implementation code
systematic-debugging
Use when encountering any bug, test failure, or unexpected behavior, before proposing fixes
requesting-code-review
Use when completing tasks, implementing major features, or before merging to verify work meets requirements
brainstorming
You MUST use this before any creative work - creating features, building components, adding functionality, modifying behavior, or planning anything new, in software or out of it (a talk, a business, a renovation).