AGENT SKILL

two-phase-flow

>- Estimate frictional pressure drop for gas-liquid two-phase pipe flow using Lockhart-Martinelli (horizontal), Beggs-Brill (inclined, all angles), or Mueller-Steinhagen-Heck (smooth quality interpolation). Use when sizing flare lines, two-phase risers, knock-out drum inlets, or boiler-tube pressure

License 许可
MIT
最近更新
2026-11-09
Stars
★ 0
Forks
0

01 前言 Front Matter

name
two-phase-flow
risk
low
source
https://github.com/jskherman/engg-skills
license
MIT
version
1.0.0
category
chemical-engineering
description
>- Estimate frictional pressure drop for gas-liquid two-phase pipe flow using Lockhart-Martinelli (horizontal), Beggs-Brill (inclined, all angles), or Mueller-Steinhagen-Heck (smooth quality interpolation). Use when sizing flare lines, two-phase risers, knock-out drum inlets, or boiler-tube pressure
imported_at
2026-09-20
source_path
skills/two-phase-flow/SKILL.md
source_repository
jskherman/engg-skills
disable-model-invocation
false

02 资源文件 2

03 SKILL.md 正文

Two-Phase Pressure Drop

Overview

Three established gas-liquid two-phase pressure-drop correlations from the fluids.two_phase module. Each correlation has its strengths:

  • Lockhart-Martinelli: classical horizontal, widely cited, ±30% typical.
  • Beggs-Brill: handles inclination (essential for risers, hilly pipelines).
  • Mueller-Steinhagen-Heck: smooth interpolation between all-liquid and all-vapor frictional gradients; recommended starting point for refrigerant evaporator design.

Prerequisites

  1. uv available.
  2. On first use, the script writes LICENSE_NOTIFICATION.txt listing the fluids library terms.

When to Use

  • Two-phase frictional pressure drop is needed in a pipe (flare, reboiler return, riser, knock-out drum inlet, slug catcher manifold).
  • Comparing two correlations to bracket the design pressure drop.

Don't use for

  • Single-phase pipe flow — use pipe-flow-pressure-drop.
  • Choked / sonic flow at a relief valve outlet — use relief-valve-sizing-api520.
  • Two-phase across a control valve — consult vendor methods; the control-valve sizing skill only covers liquid/gas ISA sizing, not two-phase trim rating.

Utility Scripts

  • uv run scripts/two_phase.py lm --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --D 0.1 --L 50 --output /tmp/lm.json
  • uv run scripts/two_phase.py beggs-brill --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --sigma 0.02 --P 1000000 --D 0.1 --L 50 --angle 30 --output /tmp/bb.json
  • uv run scripts/two_phase.py msh --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --D 0.1 --L 50 --output /tmp/msh.json

Procedure

  1. Establish phase mass flow rates and quality x = m_g / (m_g + m_l).
  2. Get phase densities and viscosities at operating conditions (use vle-flash-calculations if needed).
  3. Pick a correlation:
    • Horizontal, dilute liquid: Lockhart-Martinelli.
    • Inclined, any angle, oil/gas pipeline: Beggs-Brill.
    • Refrigerant / process evaporator, smooth quality range: Mueller- Steinhagen-Heck.
  4. Run two correlations and compare; use the higher dP for the design margin unless one is clearly outside its validity range.

Pitfalls

  • Using a single-phase friction factor on a two-phase stream.
  • Treating the slip ratio as 1 (homogeneous) for high-quality steam — fine for refrigerant boiling, not for low-pressure flashing systems.
  • Ignoring vapor density variation along the pipe; for long lines the acceleration term can dominate at the outlet.
  • Picking Lockhart-Martinelli for a vertical riser; it does not include gravity head.
  • Picking Beggs-Brill horizontal mode at 0° without verifying the correlation switches to the appropriate flow regime.
  • Forgetting that quality changes when heat is added or pressure drops (flashing or condensing). The correlations assume a constant quality over the pipe length L; for large dP / large dT, segment the pipe.
  • Reporting only one correlation's number; a 2x spread between correlations is normal for two-phase flow.
  • Using these correlations for entrained-droplet flow at high vapor velocity with a demister downstream; entrainment loading matters and is not in the correlation.

Fallback Strategies

  • If fluids is not installed, escalate to the user; there is no clean pure-Python fallback for Beggs-Brill that captures all flow regimes.
  • For very high quality (x → 1), the Lockhart-Martinelli parameter X approaches 0 and the correlation degrades; switch to a homogeneous-flow approximation or to Mueller-Steinhagen-Heck.

Verification

  • Run the listed script with representative inputs and an --output file when a deterministic calculation is available.
  • Confirm the JSON result contains ok: true, expected units, and no unhandled warnings.
  • Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.

References

  • references/correlation_choice.md — when each correlation is most suitable.
  • Beggs & Brill, Two-Phase Flow in Pipes (Univ Tulsa Press, 1991).
  • Lockhart & Martinelli, Chem Eng Prog 45, 1949.
  • Mueller-Steinhagen & Heck, Chem Eng Proc 20, 1986.
  • fluids documentation: https://fluids.readthedocs.io/fluids.two_phase.html

Anti-Patterns

  • Picking one correlation and not documenting why.
  • Designing a flare line without checking back-pressure on multiple PRV cases.
  • Treating two-phase dP as if it were 1.2x single-phase dP — that shortcut fails dramatically in slug flow.

04 同仓库更多 Skills