heat-exchanger-sizing
>- LMTD-based duty and area estimate for counter- or co-current heat exchangers, with optional multi-pass F-factor correction (via `ht`). Use when sizing a new exchanger or sanity-checking an existing one with known U. Don't use for rigorous Bell-Delaware shell-side analysis, rate-based two-phase bo
- License 许可
- MIT
- 最近更新
- 2026-11-09
- Stars
- ★ 0
- Forks
- 0
01 前言 Front Matter
- name
- heat-exchanger-sizing
- risk
- low
- source
- https://github.com/jskherman/engg-skills
- license
- MIT
- version
- 1.0.0
- category
- chemical-engineering
- description
- >- LMTD-based duty and area estimate for counter- or co-current heat exchangers, with optional multi-pass F-factor correction (via `ht`). Use when sizing a new exchanger or sanity-checking an existing one with known U. Don't use for rigorous Bell-Delaware shell-side analysis, rate-based two-phase bo
- imported_at
- 2026-09-20
- source_path
- skills/heat-exchanger-sizing/SKILL.md
- source_repository
- jskherman/engg-skills
- disable-model-invocation
- false
02 资源文件 2
- 参考文档references/methods.md144 B
- 脚本scripts/size_heat_exchanger.py3.0 KB
03 SKILL.md 正文
Heat Exchanger Sizing (LMTD)
Overview
LMTD-based duty and area calculation for a known overall heat transfer
coefficient U. Counter-current or co-current; multi-pass F-factor via the
ht library. Duty can be computed from terminal temperatures or supplied
explicitly.
Prerequisites
uvavailable.
When to Use
- Sizing a new exchanger when you have a defensible U value (vendor data, prior project) and terminal temperatures.
- Sanity-checking an existing exchanger for new conditions.
Don't use for
- Bell-Delaware shell-side design with detailed baffle / bundle configuration.
- Rate-based two-phase boiling or condensation (use a vendor or specialized tool).
- Calculating U from first principles when h on either side is unknown
(use
convective-heat-transfer-correlationsfirst).
Utility Scripts
uv run scripts/size_heat_exchanger.py --hot-in-c 150 --hot-out-c 90 --cold-in-c 25 --cold-out-c 90 --arrangement counterflow --u-w-m2-k 500 --duty-w 1e6 --output /tmp/hx.json
Procedure
- Define hot/cold inlet and outlet temperatures (°C for the bundled script).
- Decide arrangement: counterflow (preferred), co-current, or multi-pass with F-factor.
- Estimate U from either side's h (or vendor data); typical ranges: liquid-liquid 300-1000 W/m²K, liquid-gas 30-100, condensing steam 2000-5000, boiling 1000-4000.
- Provide duty from one stream's sensible heat (m × cp × ΔT) or pass the value if known.
- Run the script. Inspect area; round up to the nearest commercial bundle size.
- Cross-check by computing the other stream's duty and verifying the energy balance closes.
Pitfalls
- Using bare LMTD without the F-factor for multi-pass exchangers.
- Picking U from a textbook table without flagging the fouling factor (overstates U).
- Forgetting that LMTD blows up to ±infinity when terminal differences approach zero (temperature pinch).
- Using sensible-heat duty for a two-phase service (latent heat dominates).
- Reporting required area without acknowledging the fouling allowance.
- Choosing LMTD when one stream is isothermal (condensing / boiling) and using F = 1 by default. Even for single-phase the F-factor is < 1 for multi-pass.
- Picking shell-and-tube as default; for liquid-liquid services with low fouling, a plate-and-frame is often smaller and cheaper.
- Treating the calculated area as final without vendor-validated TEMA layout and pressure-drop check.
Fallback Strategies
- If
ht.LMTDis unavailable, the script falls back to the direct LMTD formula and flags the substitution. - If only one stream's enthalpy data is supplied, the script computes the matching cold/hot side from the energy balance, but only when arrangement allows it.
Verification
- Run the listed script with representative inputs and an
--outputfile when a deterministic calculation is available. - Confirm the JSON result contains
ok: true, expected units, and no unhandled warnings. - Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.
References
references/methods.md— assumptions, formulas, and U ranges.- TEMA standards (procure separately).
- Sinnott / Coulson & Richardson Vol 6 for U guidance.
Anti-Patterns
- Reporting required area without specifying U and fouling factors.
- Using LMTD with widely different specific heats across the exchanger (Cp varies strongly with T).
- Sizing without checking the temperature pinch.
04 同仓库更多 Skills
dei-assessment
Assess diversity, equity, and inclusion with metrics. TRIGGERS - Use when user needs help with dei-assessment related tasks.
dei-action-plan
Create DEI action plans with goals and initiatives. TRIGGERS - Use when user needs help with dei-action-plan related tasks.
culture-fit-assessment
Design culture add assessment processes. TRIGGERS - Use when user needs help with culture-fit-assessment related tasks.
cowork-to-code-bridge
Use an already-installed, independently verified cowork-to-code bridge to run narrowly approved actions on the user's own macOS, Linux, or WSL2 machine through a local file queue.
counter-offer-response
Draft counter-offer responses for retention. TRIGGERS - Use when user needs help with counter-offer-response related tasks.
continuous-feedback-system