bio-causal-genomics-pleiotropy-detection
Detect and correct for horizontal pleiotropy in Mendelian randomization analyses using MR-PRESSO for outlier removal, MR-Egger regression for directional pleiotropy, and Steiger filtering for variant directionality. Use when validating MR results, detecting pleiotropic instrum...
- License 许可
- MIT
- 最近更新
- 2026-10-12
- Stars
- ★ 2
- Forks
- 0
01 前言 Front Matter
- name
- bio-causal-genomics-pleiotropy-detection
- author
- AIPOCH
- license
- MIT
- description
- Detect and correct for horizontal pleiotropy in Mendelian randomization analyses using MR-PRESSO for outlier removal, MR-Egger regression for directional pleiotropy, and Steiger filtering for variant directionality. Use when validating MR results, detecting pleiotropic instrum...
02 资源文件 2
- 参考文档POLISH_CHANGELOG.md637 B
- 参考文档usage-guide.md2.8 KB
03 SKILL.md 正文
Version Compatibility
Reference examples tested with: MR-PRESSO 1.0+, TwoSampleMR 0.5+
Before using code patterns, verify installed versions match. If versions differ:
- R:
packageVersion("<pkg>")then?function_nameto verify parameters
If code throws ImportError, AttributeError, or TypeError, introspect the installed package and adapt the example to match the actual API rather than retrying.
Pleiotropy Detection
"Check my MR results for pleiotropic bias" → Detect and correct for horizontal pleiotropy using outlier removal (MR-PRESSO), directional pleiotropy testing (MR-Egger intercept), and variant directionality filtering (Steiger) to validate causal inference results.
- R:
MRPRESSO::mr_presso()for global and distortion tests - R:
TwoSampleMR::mr_egger_regression()for Egger intercept test
Overview
Horizontal pleiotropy violates the exclusion restriction assumption of MR: instruments affect the outcome through pathways other than the exposure. Detecting and correcting for pleiotropy is essential for valid causal inference.
Types of pleiotropy:
- Vertical (mediated): Instrument -> exposure -> outcome (valid, not a problem)
- Horizontal (direct): Instrument -> outcome bypassing exposure (violates MR assumptions)
- Balanced: Pleiotropic effects cancel out (IVW still valid, Egger intercept ~0)
- Directional: Pleiotropic effects are systematic (biases IVW, Egger detects this)
MR-PRESSO
Goal: Detect and remove pleiotropic outlier instruments from an MR analysis.
Approach: Run MR-PRESSO to test for global pleiotropy, identify individual outlier SNPs, test whether their removal changes the causal estimate (distortion test), and obtain a corrected estimate.
# install.packages('remotes')
# remotes::install_github('rondolab/MR-PRESSO')
library(MRPRESSO)
# Input: harmonized data from TwoSampleMR
# Columns needed: beta.exposure, beta.outcome, se.exposure, se.outcome
presso_input <- data.frame(
bx = dat$beta.exposure,
by = dat$beta.outcome,
bxse = dat$se.exposure,
byse = dat$se.outcome
)
# --- Run MR-PRESSO ---
# NbDistribution: Number of simulations for null distribution (minimum 1000)
# SignifThreshold: P-value threshold for outlier detection (0.05 standard)
presso_result <- mr_presso(
BetaOutcome = 'by', BetaExposure = 'bx',
SdOutcome = 'byse', SdExposure = 'bxse',
OUTLIERtest = TRUE, DISTORTIONtest = TRUE,
data = presso_input,
NbDistribution = 5000,
SignifThreshold = 0.05
)
# --- Global test ---
# Tests whether there is any pleiotropy among instruments
# Significant p-value: Evidence of horizontal pleiotropy
global_p <- presso_result$`MR-PRESSO results`$`Global Test`$Pvalue
cat('Global test p-value:', global_p, '\n')
# --- Outlier test ---
# Identifies individual pleiotropic SNPs
outliers <- presso_result$`MR-PRESSO results`$`Outlier Test`
cat('\nOutlier test results:\n')
print(outliers)
# Outlier SNPs (p < 0.05)
outlier_indices <- which(outliers$Pvalue < 0.05)
cat('Outlier SNPs:', length(outlier_indices), '\n')
# --- Distortion test ---
# Tests whether removing outliers significantly changes the causal estimate
# Significant: Outliers were meaningfully biasing the estimate
distortion_p <- presso_result$`MR-PRESSO results`$`Distortion Test`$Pvalue
cat('Distortion test p-value:', distortion_p, '\n')
# --- Corrected estimate ---
# MR estimate after removing outlier SNPs
main_results <- presso_result$`Main MR results`
cat('\nRaw IVW estimate:', main_results$`Causal Estimate`[1], '\n')
cat('Corrected IVW estimate:', main_results$`Causal Estimate`[2], '\n')
MR-Egger Diagnostics
Goal: Test for directional pleiotropy and obtain a pleiotropy-adjusted causal estimate.
Approach: Fit MR-Egger regression where the intercept estimates average pleiotropic bias, and check I-squared for instrument strength under the NOME assumption.
library(TwoSampleMR)
# MR-Egger regression allows for a non-zero intercept
# The intercept estimates the average pleiotropic effect
egger <- mr_egger_regression(dat$beta.exposure, dat$beta.outcome,
dat$se.exposure, dat$se.outcome)
# --- Egger intercept ---
# Significant intercept (p < 0.05): Directional pleiotropy present
# Non-significant: No evidence (but low power with < 10 SNPs)
cat('Egger intercept:', round(egger$b_i, 5), '\n')
cat('Intercept SE:', round(egger$se_i, 5), '\n')
cat('Intercept p-value:', format.pval(egger$pval_i), '\n')
# --- Egger slope ---
# Valid causal estimate EVEN with directional pleiotropy (InSIDE assumption)
cat('\nEgger causal estimate:', round(egger$b, 4), '\n')
cat('Egger SE:', round(egger$se, 4), '\n')
cat('Egger p-value:', format.pval(egger$pval), '\n')
# --- I-squared for Egger ---
# I^2 measures instrument strength for MR-Egger specifically
# I^2 > 0.9: Egger estimate reliable
# I^2 < 0.6: Egger has low power, interpret with caution (NOME violation)
isq <- Isq(dat$beta.exposure, dat$se.exposure)
cat('\nI-squared:', round(isq, 3), '\n')
if (isq < 0.9) cat('Warning: I-squared < 0.9; Egger estimate may be unreliable (NOME violation)\n')
Steiger Filtering
Goal: Verify that instruments act in the correct causal direction (exposure -> outcome, not reverse).
Approach: Apply the Steiger test to each instrument, remove those explaining more outcome variance than exposure variance, and re-run MR on filtered instruments.
library(TwoSampleMR)
# Steiger test: Verify each instrument explains more variance in
# the exposure than the outcome. Instruments failing this test
# may act through a reverse causal pathway.
steiger <- steiger_filtering(dat)
# Keep only correctly oriented instruments
dat_steiger <- steiger[steiger$steiger_dir == TRUE, ]
cat('Instruments passing Steiger filter:', nrow(dat_steiger), 'of', nrow(steiger), '\n')
# Re-run MR with filtered instruments
results_steiger <- mr(dat_steiger)
print(results_steiger[, c('method', 'nsnp', 'b', 'se', 'pval')])
# Directionality test (aggregate)
direction <- directionality_test(dat)
cat('\nCorrect causal direction:', direction$correct_causal_direction, '\n')
cat('Steiger p-value:', format.pval(direction$steiger_pval), '\n')
Additional Sensitivity Methods
library(TwoSampleMR)
# --- Contamination mixture ---
# Assumes some instruments are valid, others are not
# Does not require majority valid assumption
mr_conmix <- mr(dat, method_list = 'mr_raps')
# --- MR-RAPS ---
# NOTE: MRAPS CRAN package was archived March 2025.
# Use the MendelianRandomization package instead, or install from GitHub:
# remotes::install_github('qingyuanzhao/mr.raps')
library(MendelianRandomization)
mr_input <- mr_input(
bx = dat$beta.exposure, bxse = dat$se.exposure,
by = dat$beta.outcome, byse = dat$se.outcome
)
raps_result <- mr_raps(mr_input)
cat('MR-RAPS estimate:', raps_result$Estimate, '\n')
cat('MR-RAPS p-value:', raps_result$Pvalue, '\n')
# --- Multivariable MR ---
# Controls for pleiotropy by including multiple exposures simultaneously
# e.g., adjust for BMI when estimating effect of lipids on CHD
exposure1 <- extract_instruments('ieu-a-300') # LDL
exposure2 <- extract_instruments('ieu-a-302') # HDL
# Combine and perform multivariable MR
# (See TwoSampleMR vignette for full multivariable workflow)
Comprehensive Sensitivity Framework
Goal: Run a complete battery of MR sensitivity analyses to validate causal findings.
Approach: Apply IVW, MR-Egger, weighted median, weighted mode, heterogeneity, Egger intercept, leave-one-out, and MR-PRESSO in a single function and summarize results.
library(TwoSampleMR)
library(MRPRESSO)
run_sensitivity <- function(dat) {
results <- list()
# 1. IVW (primary)
results$ivw <- mr(dat, method_list = 'mr_ivw')
# 2. MR-Egger
results$egger <- mr(dat, method_list = 'mr_egger_regression')
# 3. Weighted median (robust to 50% invalid instruments)
results$median <- mr(dat, method_list = 'mr_weighted_median')
# 4. Weighted mode
results$mode <- mr(dat, method_list = 'mr_weighted_mode')
# 5. Heterogeneity
results$het <- mr_heterogeneity(dat)
# 6. Egger intercept
results$pleio <- mr_pleiotropy_test(dat)
# 7. Leave-one-out
results$loo <- mr_leaveoneout(dat)
# 8. MR-PRESSO
presso_input <- data.frame(
bx = dat$beta.exposure, by = dat$beta.outcome,
bxse = dat$se.exposure, byse = dat$se.outcome
)
results$presso <- mr_presso(
BetaOutcome = 'by', BetaExposure = 'bx',
SdOutcome = 'byse', SdExposure = 'bxse',
OUTLIERtest = TRUE, DISTORTIONtest = TRUE,
data = presso_input, NbDistribution = 5000, SignifThreshold = 0.05
)
results
}
summarize_sensitivity <- function(sens) {
cat('=== MR Sensitivity Analysis Summary ===\n\n')
# Method comparison
all_mr <- rbind(sens$ivw, sens$egger, sens$median, sens$mode)
cat('Method comparison:\n')
print(all_mr[, c('method', 'b', 'se', 'pval')])
# Heterogeneity
cat('\nHeterogeneity (Cochran Q):\n')
cat(' Q p-value (IVW):', sens$het$Q_pval[sens$het$method == 'Inverse variance weighted'], '\n')
# Egger intercept
cat('\nEgger intercept:\n')
cat(' Intercept:', sens$pleio$egger_intercept, '\n')
cat(' P-value:', sens$pleio$pval, '\n')
# MR-PRESSO global test
cat('\nMR-PRESSO global test p-value:',
sens$presso$`MR-PRESSO results`$`Global Test`$Pvalue, '\n')
cat('\n--- Interpretation ---\n')
cat('Consistent estimates across methods: Evidence strengthened\n')
cat('Significant Egger intercept: Directional pleiotropy present\n')
cat('Significant MR-PRESSO global: Horizontal pleiotropy detected\n')
cat('Significant heterogeneity: Instruments may be invalid\n')
}
STROBE-MR Reporting
When reporting MR analyses, follow STROBE-MR guidelines:
- Report all MR methods tested (not just the most significant)
- Report heterogeneity Q-statistic and p-value
- Report Egger intercept with p-value
- Report MR-PRESSO global test and number of outliers removed
- Report F-statistics for instrument strength
- Report Steiger directionality test
- State whether results are consistent across sensitivity analyses
- Acknowledge limitations of the MR assumptions
Related Skills
- mendelian-randomization - Primary MR analysis that pleiotropy tests validate
- fine-mapping - Identify causal variants at instrument loci
- population-genetics/association-testing - GWAS data for MR instruments
Input Validation
This skill accepts requests that match the documented purpose of bio-causal-genomics-pleiotropy-detection and include enough context to complete the workflow safely.
Do not continue the workflow when the request is out of scope, missing a critical input, or would require unsupported assumptions. Instead respond:
bio-causal-genomics-pleiotropy-detectiononly handles its documented workflow. Please provide the missing required inputs or switch to a more suitable skill.
04 同仓库更多 Skills
bio-workflows-metabolomics-pipeline
Orchestrates the untargeted LC-MS metabolomics pipeline end-to-end (xcms 4.x feature extraction, QC/drift/normalization, confidence-stratified annotation, permutation-validated statistics, background-aware pathway mapping), naming what each stage decides and where it silently fails. Use when running a full LC-MS metabolomics study from raw mzML to enriched pathways and needing the honest handoffs between stages. Each stage defers to its component skill for parameters and traps; for stable-isotope flux (a separate branch, not this untargeted flow) see metabolomics/isotope-tracing.
bio-metabolomics-xcms-preprocessing
Programmatic untargeted LC-MS feature extraction in R with the modern xcms 4.x MsExperiment/XcmsExperiment API, taking raw mzML to a feature table via CentWave peak detection, retention-time alignment, peak-density correspondence, gap-filling, CAMERA redundancy collapse, and built-in QC feature filtering. Use when converting centroided LC-MS runs into a features-by-samples matrix and deciding centWave/grouping/alignment parameters. For drift correction and QC/CV filtering execution see metabolomics/normalization-qc; for metabolite identification see metabolomics/metabolite-annotation; for the MS-DIAL GUI alternative with MS2Dec deconvolution see metabolomics/msdial-preprocessing; for downstream statistics see metabolomics/statistical-analysis.
bio-metabolomics-statistical-analysis
Decision-grade statistical analysis for metabolomics intensity tables. Covers transformation and scaling (Pareto vs unit-variance as a hidden hypothesis), unsupervised structure (PCA/HCA for QC), permutation-validated PLS-DA/OPLS-DA (R2 vs Q2, double CV, VIP as heuristic), univariate testing (Welch/Mann-Whitney/ANOVA/LMM with covariate adjustment), and dependence-aware multiple testing. Use when testing which metabolites differ, building or validating a discriminant model, choosing a scaling, or correcting many correlated tests. For sample-wise normalization/drift correction see metabolomics/normalization-qc; for ML classifiers and selection-inside-CV leakage see machine-learning/biomarker-discovery and machine-learning/model-validation; for pathway interpretation see metabolomics/pathway-mapping; for design/power/multiplicity regime see experimental-design/multiple-testing.
bio-metabolomics-pathway-mapping
Maps metabolomics results to biological pathways via over-representation (ORA), metabolite-set enrichment (MSEA/QEA), mummichog/PSEA on raw m/z peaks, and network-diffusion enrichment (FELLA), with correct background-set construction and honest interpretive ceilings. Use when interpreting differential metabolites or an untargeted LC-MS feature table in pathway context, choosing ORA vs MSEA vs mummichog vs topology, or setting the reference/background set. For annotation confidence levels feeding ORA see metabolomics/metabolite-annotation; for gene-set concepts see pathway-analysis/go-enrichment and pathway-analysis/gsea; for joint gene+metabolite pathways see multi-omics-integration/mofa-integration.
bio-metabolomics-normalization-qc
Designs QC, corrects signal drift, removes batch effects, filters features, normalizes samples, and imputes missing values for untargeted LC-MS/GC-MS metabolomics, framing each step as a measurement model that can create or erase biological signal. Use when processing a peak/feature table before statistical analysis, choosing a drift-correction or sample-normalization method, deciding QC RSD vs D-ratio filtering, or handling left-censored missing values. The feature table is produced by metabolomics/xcms-preprocessing or metabolomics/msdial-preprocessing; transformation/scaling for modeling defers to metabolomics/statistical-analysis; cross-study design issues link to experimental-design/batch-design.
bio-metabolomics-msdial-preprocessing
Runs the MS-DIAL preprocessing workflow (peak picking, MS2Dec spectral deconvolution, alignment, gap-filling) and imports the alignment-result table into R or Python with honest filtering. Use when preprocessing LC-MS DDA/DIA (SWATH) or GC-MS raw data with MS-DIAL, deciding MS-DIAL vs XCMS, configuring the MSDIALCUI console run, or parsing an MS-DIAL export into a clean feature matrix. For programmatic R peak detection and the feature-table-as-artifact framing see metabolomics/xcms-preprocessing; for lipid annotation mode see metabolomics/lipidomics; for MSI-level confidence honesty see metabolomics/metabolite-annotation; for drift correction and QC see metabolomics/normalization-qc.