diagnostic-study-quality-assessment-quadas-2
Analyzes clinical diagnostic accuracy studies for bias using the QUADAS-2 tool. Use when Claude needs to assess the quality, risk of bias, or applicability of diagnostic accuracy studies (e.g., "Assess this paper using QUADAS-2").
- License 许可
- MIT
- 最近更新
- 2026-10-12
- Stars
- ★ 2
- Forks
- 0
01 前言 Front Matter
- name
- diagnostic-study-quality-assessment-quadas-2
- author
- AIPOCH
- license
- MIT
- description
- Analyzes clinical diagnostic accuracy studies for bias using the QUADAS-2 tool. Use when Claude needs to assess the quality, risk of bias, or applicability of diagnostic accuracy studies (e.g., "Assess this paper using QUADAS-2").
02 资源文件 5
- 参考文档POLISH_CHANGELOG.md651 B
- 参考文档references/api_reference.md990 B
- 参考文档references/quadas_2_criteria.md2.0 KB
- 脚本scripts/pdf_extractor.py3.9 KB
- 脚本scripts/quadas_assessment.py454 B
03 SKILL.md 正文
Clinical Study Bias Assessment (QUADAS-2)
This skill evaluates clinical diagnostic accuracy studies for bias and applicability concerns using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool.
Workflow
To assess a study, follow these steps:
-
Analyze Patient Selection:
- Assess if the sample was consecutive or random.
- Check for case-control design (should be avoided).
- Check for inappropriate exclusions.
- See
references/quadas_2_criteria.mdfor detailed signaling questions.
-
Analyze Index Test:
- Assess if the index test results were interpreted without knowledge of the reference standard.
- Check if the threshold was pre-specified.
-
Analyze Reference Standard:
- Assess if the reference standard correctly classifies the target condition.
- Check if reference standard results were interpreted without knowledge of the index test.
-
Analyze Flow and Timing:
- Assess the interval between index test and reference standard.
- Check if all patients received the reference standard (and the same one).
- Check if all patients were included in the analysis.
Output Format
For each domain (Patient Selection, Index Test, Reference Standard, Flow and Timing), you MUST output the findings in the following structure:
### [Domain Name]
**[Signaling Question 1]?**
- Comments: [Explanation in Chinese]
- Quote: [Original text quote]
- Answer: [Yes/No/Unclear]
... (Repeat for all signaling questions)
Quality Rules
- Language: Explanations (Comments) must be in Chinese.
- Evidence: Every judgment must be supported by a direct quote from the paper.
- Strictness: If information is missing, select "Unclear". Do not guess.
PDF Parsing Tool
For processing PDF literature, you can use the provided Python script:
# Install dependencies
pip install PyPDF2
# Extract full text
python scripts/pdf_extractor.py "paper.pdf"
# Extract specific page range
python scripts/pdf_extractor.py "paper.pdf" 5 15
The script will automatically extract the text, which you can then copy and send to me for QUADAS-2 assessment.
Input Validation
This skill accepts requests that match the documented purpose of diagnostic-study-quality-assessment-quadas-2 and include enough context to complete the workflow safely.
Do not continue the workflow when the request is out of scope, missing a critical input, or would require unsupported assumptions. Instead respond:
diagnostic-study-quality-assessment-quadas-2only handles its documented workflow. Please provide the missing required inputs or switch to a more suitable skill.
References
- QUADAS-2 Criteria: Detailed signaling questions and judgment guidelines.
When to Use
- Use this skill when the user explicitly needs to perform the core task of diagnostic-study-quality-assessment-quadas-2 and has provided the minimum executable input.
- Use this skill when you need a structured deliverable rather than general advice.
- Use this skill when the current task can be completed using this skill's bundled scripts, templates, or reference materials.
When Not to Use
- Do not proceed when required input files, identifiers, parameters, or context are missing — ask the user to provide them first.
- Do not assume capabilities beyond this skill's declared scope when the user requests external operations or inferences.
- Do not proceed without user confirmation when overwriting existing results, executing high-cost batch operations, or expanding task scope.
Required Inputs
| Field | Required | Format/Source | Example | If Missing |
|---|---|---|---|---|
| User task description | Yes | Text | Research question, writing goal, analysis objective | Stop and ask user to provide |
| Primary input material | Depends on task | Text, file path, ID, table, or literature | PMID, PDF, CSV, DOCX, keywords, etc. | Specify which material type is missing |
| Output preference | No | Text | Language, format, target journal, template | Use skill default format |
Output Contract
- Primary output: Structured result or target file aligned with this skill's objective.
- Optional output: Intermediate check notes, issue list, supplementary suggestions, or generated file paths.
- Format requirement: Unless the user specifies otherwise, prefer stable, reviewable Markdown or JSON; if the skill's bundled script requires a fixed format, use that format.
- If partially complete: Must explicitly mark as PARTIAL and state which steps are completed and which remain.
Failure Handling
- Missing critical input: Explicitly state which fields, files, or identifiers are missing and pause.
- Script, template, or resource execution failure: Report the failing step, likely cause, and recovery suggestions — do not silently degrade.
- Partial completion only: Return the verified portion first, then list remaining blockers and suggested next steps.
User Checkpoints
- Before executing batch processing, overwriting files, long-running searches, or multi-stage generation, confirm scope and output format with the user.
- Before proceeding when a key judgment is ambiguous, evidence is insufficient, or the workflow is entering the next stage, confirm with the user.
Quick Validation
- Check that key scripts, templates, or reference file paths this skill depends on exist.
- Check that the final output contains the core fields, sections, or files specified for this task.
- Check that results clearly mark assumptions, limitations, and incomplete items.
04 同仓库更多 Skills
bio-workflows-metabolomics-pipeline
Orchestrates the untargeted LC-MS metabolomics pipeline end-to-end (xcms 4.x feature extraction, QC/drift/normalization, confidence-stratified annotation, permutation-validated statistics, background-aware pathway mapping), naming what each stage decides and where it silently fails. Use when running a full LC-MS metabolomics study from raw mzML to enriched pathways and needing the honest handoffs between stages. Each stage defers to its component skill for parameters and traps; for stable-isotope flux (a separate branch, not this untargeted flow) see metabolomics/isotope-tracing.
bio-metabolomics-xcms-preprocessing
Programmatic untargeted LC-MS feature extraction in R with the modern xcms 4.x MsExperiment/XcmsExperiment API, taking raw mzML to a feature table via CentWave peak detection, retention-time alignment, peak-density correspondence, gap-filling, CAMERA redundancy collapse, and built-in QC feature filtering. Use when converting centroided LC-MS runs into a features-by-samples matrix and deciding centWave/grouping/alignment parameters. For drift correction and QC/CV filtering execution see metabolomics/normalization-qc; for metabolite identification see metabolomics/metabolite-annotation; for the MS-DIAL GUI alternative with MS2Dec deconvolution see metabolomics/msdial-preprocessing; for downstream statistics see metabolomics/statistical-analysis.
bio-metabolomics-statistical-analysis
Decision-grade statistical analysis for metabolomics intensity tables. Covers transformation and scaling (Pareto vs unit-variance as a hidden hypothesis), unsupervised structure (PCA/HCA for QC), permutation-validated PLS-DA/OPLS-DA (R2 vs Q2, double CV, VIP as heuristic), univariate testing (Welch/Mann-Whitney/ANOVA/LMM with covariate adjustment), and dependence-aware multiple testing. Use when testing which metabolites differ, building or validating a discriminant model, choosing a scaling, or correcting many correlated tests. For sample-wise normalization/drift correction see metabolomics/normalization-qc; for ML classifiers and selection-inside-CV leakage see machine-learning/biomarker-discovery and machine-learning/model-validation; for pathway interpretation see metabolomics/pathway-mapping; for design/power/multiplicity regime see experimental-design/multiple-testing.
bio-metabolomics-pathway-mapping
Maps metabolomics results to biological pathways via over-representation (ORA), metabolite-set enrichment (MSEA/QEA), mummichog/PSEA on raw m/z peaks, and network-diffusion enrichment (FELLA), with correct background-set construction and honest interpretive ceilings. Use when interpreting differential metabolites or an untargeted LC-MS feature table in pathway context, choosing ORA vs MSEA vs mummichog vs topology, or setting the reference/background set. For annotation confidence levels feeding ORA see metabolomics/metabolite-annotation; for gene-set concepts see pathway-analysis/go-enrichment and pathway-analysis/gsea; for joint gene+metabolite pathways see multi-omics-integration/mofa-integration.
bio-metabolomics-normalization-qc
Designs QC, corrects signal drift, removes batch effects, filters features, normalizes samples, and imputes missing values for untargeted LC-MS/GC-MS metabolomics, framing each step as a measurement model that can create or erase biological signal. Use when processing a peak/feature table before statistical analysis, choosing a drift-correction or sample-normalization method, deciding QC RSD vs D-ratio filtering, or handling left-censored missing values. The feature table is produced by metabolomics/xcms-preprocessing or metabolomics/msdial-preprocessing; transformation/scaling for modeling defers to metabolomics/statistical-analysis; cross-study design issues link to experimental-design/batch-design.
bio-metabolomics-msdial-preprocessing
Runs the MS-DIAL preprocessing workflow (peak picking, MS2Dec spectral deconvolution, alignment, gap-filling) and imports the alignment-result table into R or Python with honest filtering. Use when preprocessing LC-MS DDA/DIA (SWATH) or GC-MS raw data with MS-DIAL, deciding MS-DIAL vs XCMS, configuring the MSDIALCUI console run, or parsing an MS-DIAL export into a clean feature matrix. For programmatic R peak detection and the feature-table-as-artifact framing see metabolomics/xcms-preprocessing; for lipid annotation mode see metabolomics/lipidomics; for MSI-level confidence honesty see metabolomics/metabolite-annotation; for drift correction and QC see metabolomics/normalization-qc.