[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"skill:01M7B8XVYVY4CTF6FZMYMKPCMJ":3,"skill-same:01M7B8XVYVY4CTF6FZMYMKPCMJ":85},{"skillNo":4,"name":5,"nameZh":6,"description":7,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":6,"repositoryNo":12,"starsCount":13,"licenseSpdxId":14,"licenseFileUrl":15,"sourceHtmlUrl":16,"categories":17,"keywords":18,"publishedAt":19,"linkOnly":20,"markdownContent":21,"markdownBody":22,"frontMatter":23,"refName":49,"commitSha":50,"skillDirectory":51,"forksCount":13,"repositoryHtmlUrl":52,"repositoryHomepageUrl":6,"ownerHtmlUrl":53,"ownerBlogUrl":6,"ownerDescription":6,"updatedAt":54,"install":55,"resources":68},"01M7B8XVYVY4CTF6FZMYMKPCMJ","performing-scada-hmi-security-assessment",null,"Perform security assessments of SCADA Human-Machine Interface (HMI) systems to identify vulnerabilities in web-based HMIs, thin-client configurations, authentication mechanisms, and communication channels between HMI and PLCs, aligned with IEC 62443 and NIST SP 800-82 guidelines.","vikasvardhanv\u002Fjerry_skills","vikasvardhanv","https:\u002F\u002Favatars.githubusercontent.com\u002Fu\u002F99010657?v=4","01M7B2B0VN78W7529RQX5BR6DZ","01M7B2B0WDNTXJHRK3QNPNWRP6",0,"Apache-2.0","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fcurated_premium_skills\u002FAnthropic-Cybersecurity-Skills\u002Fskills\u002Fperforming-scada-hmi-security-assessment\u002FLICENSE","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fcurated_premium_skills\u002FAnthropic-Cybersecurity-Skills\u002Fskills\u002Fperforming-scada-hmi-security-assessment\u002FSKILL.md",[],[],"2026-11-15 14:19:17",false,"---\nname: performing-scada-hmi-security-assessment\ndescription: 'Perform security assessments of SCADA Human-Machine Interface (HMI)\n  systems to identify vulnerabilities in web-based HMIs, thin-client configurations,\n  authentication mechanisms, and communication channels between HMI and PLCs, aligned\n  with IEC 62443 and NIST SP 800-82 guidelines.\n\n  '\ndomain: cybersecurity\nsubdomain: ot-ics-security\ntags:\n- ot-security\n- ics\n- scada\n- hmi\n- security-assessment\n- vulnerability\n- iec62443\n- nist-800-82\nversion: '1.0'\nauthor: mahipal\nlicense: Apache-2.0\nnist_csf:\n- PR.IR-01\n- DE.CM-01\n- ID.AM-05\n- GV.OC-02\nmitre_attack:\n- T1078\n- T1190\n- T1059\n- T0816\n- T0836\n---\n\n# Performing SCADA HMI Security Assessment\n\n## When to Use\n\n- When assessing the security posture of HMI systems in SCADA\u002FDCS environments\n- When evaluating web-based HMI interfaces for common web vulnerabilities\n- When auditing HMI authentication, authorization, and session management\n- When testing communication security between HMIs and PLCs\u002FRTUs\n- When preparing for IEC 62443 or NERC CIP compliance assessments\n\n**Do not use** for testing HMIs in active production without a maintenance window and rollback plan, for PLC-level protocol analysis (see performing-s7comm-protocol-security-analysis), or for general web application testing on non-OT systems.\n\n## Prerequisites\n\n- HMI system inventory with vendor, version, and network configuration details\n- Lab or test environment mirroring production HMI setup (preferred for active testing)\n- Authorization from plant operations for testing during maintenance windows\n- NIST SP 800-82 and IEC 62443 security requirements documentation\n- Network capture capability on HMI-to-PLC communication segment\n\n## Workflow\n\n### Step 1: Assess HMI Attack Surface\n\n```python\n#!\u002Fusr\u002Fbin\u002Fenv python3\n\"\"\"SCADA HMI Security Assessment Tool.\n\nEvaluates HMI security across authentication, communication,\nconfiguration, and web interface categories aligned with\nIEC 62443 and NIST SP 800-82 requirements.\n\"\"\"\n\nimport json\nimport sys\nfrom datetime import datetime\nfrom typing import Dict, List\n\ntry:\n    import requests\nexcept ImportError:\n    print(\"Install requests: pip install requests\")\n    sys.exit(1)\n\n\nclass HMISecurityAssessment:\n    \"\"\"Performs security assessment of SCADA HMI systems.\"\"\"\n\n    def __init__(self, hmi_info: dict):\n        self.hmi_info = hmi_info\n        self.findings = []\n        self.checks_run = 0\n        self.checks_passed = 0\n\n    def check_authentication(self):\n        \"\"\"Assess HMI authentication mechanisms.\"\"\"\n        checks = [\n            {\n                \"id\": \"AUTH-01\",\n                \"name\": \"Password complexity enforcement\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.7\",\n                \"description\": \"HMI must enforce minimum password complexity requirements\",\n                \"test\": \"Verify minimum length >= 8, complexity rules, history >= 5\",\n            },\n            {\n                \"id\": \"AUTH-02\",\n                \"name\": \"Account lockout policy\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.11\",\n                \"description\": \"HMI must lock accounts after failed login attempts\",\n                \"test\": \"Verify lockout after 5 failed attempts, lockout duration >= 15 min\",\n            },\n            {\n                \"id\": \"AUTH-03\",\n                \"name\": \"Default credentials changed\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.5\",\n                \"description\": \"All default vendor credentials must be changed\",\n                \"test\": \"Attempt login with known vendor defaults (admin\u002Fadmin, operator\u002Foperator)\",\n            },\n            {\n                \"id\": \"AUTH-04\",\n                \"name\": \"Role-based access control\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 2.1\",\n                \"description\": \"HMI must separate operator, engineer, and admin roles\",\n                \"test\": \"Verify operator role cannot access engineering functions\",\n            },\n            {\n                \"id\": \"AUTH-05\",\n                \"name\": \"Session timeout enforcement\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.12\",\n                \"description\": \"HMI sessions must time out after inactivity\",\n                \"test\": \"Verify session timeout \u003C= 15 minutes for operator, \u003C= 5 for admin\",\n            },\n            {\n                \"id\": \"AUTH-06\",\n                \"name\": \"Multi-factor authentication for remote access\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.13\",\n                \"description\": \"Remote HMI access requires MFA\",\n                \"test\": \"Verify MFA is enforced for all non-local HMI connections\",\n            },\n        ]\n\n        print(f\"\\n--- AUTHENTICATION ASSESSMENT ---\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Ref: {check['iec62443_ref']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def check_communication_security(self):\n        \"\"\"Assess HMI-to-PLC communication security.\"\"\"\n        checks = [\n            {\n                \"id\": \"COMM-01\",\n                \"name\": \"Encrypted HMI-PLC communication\",\n                \"description\": \"Traffic between HMI and PLCs should use encrypted protocols (OPC UA with TLS)\",\n                \"test\": \"Capture HMI-PLC traffic and verify encryption (Wireshark TLS handshake)\",\n            },\n            {\n                \"id\": \"COMM-02\",\n                \"name\": \"HMI write command authentication\",\n                \"description\": \"Write commands from HMI to PLC should be authenticated\",\n                \"test\": \"Verify that write operations require operator confirmation\u002Fauthentication\",\n            },\n            {\n                \"id\": \"COMM-03\",\n                \"name\": \"Web HMI uses HTTPS\",\n                \"description\": \"Web-based HMI interfaces must use TLS 1.2+ with valid certificates\",\n                \"test\": \"Check TLS version, cipher suites, certificate validity\",\n            },\n            {\n                \"id\": \"COMM-04\",\n                \"name\": \"No cleartext protocols in use\",\n                \"description\": \"Telnet, FTP, HTTP must not be used for HMI access or management\",\n                \"test\": \"Port scan HMI for cleartext protocol services\",\n            },\n        ]\n\n        print(f\"\\n--- COMMUNICATION SECURITY ASSESSMENT ---\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def check_web_hmi_security(self):\n        \"\"\"Assess web-based HMI for common web vulnerabilities.\"\"\"\n        hmi_url = self.hmi_info.get(\"url\", \"\")\n        if not hmi_url:\n            print(f\"\\n  [SKIP] No web HMI URL provided\")\n            return\n\n        checks = [\n            {\n                \"id\": \"WEB-01\",\n                \"name\": \"Cross-Site Scripting (XSS)\",\n                \"owasp\": \"A7:2017\",\n                \"test\": \"Test input fields with XSS payloads in tag names, alarm messages\",\n            },\n            {\n                \"id\": \"WEB-02\",\n                \"name\": \"Cross-Site Request Forgery (CSRF)\",\n                \"owasp\": \"A8:2013\",\n                \"test\": \"Verify CSRF tokens on state-changing operations (setpoint changes)\",\n            },\n            {\n                \"id\": \"WEB-03\",\n                \"name\": \"Insecure Direct Object References\",\n                \"owasp\": \"A4:2013\",\n                \"test\": \"Manipulate URL parameters to access other users HMI views\",\n            },\n            {\n                \"id\": \"WEB-04\",\n                \"name\": \"Security Headers\",\n                \"test\": \"Verify X-Frame-Options, CSP, X-Content-Type-Options headers\",\n            },\n            {\n                \"id\": \"WEB-05\",\n                \"name\": \"Privileged file system access (CVE-2025-0921)\",\n                \"test\": \"Check Ignition SCADA for privileged file system vulnerability via project files\",\n            },\n        ]\n\n        print(f\"\\n--- WEB HMI SECURITY ASSESSMENT ---\")\n        print(f\"  Target: {hmi_url}\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def check_hardening(self):\n        \"\"\"Assess HMI operating system and application hardening.\"\"\"\n        checks = [\n            {\n                \"id\": \"HARD-01\",\n                \"name\": \"OS patch level\",\n                \"test\": \"Verify HMI OS is patched within SLA (typically 90 days for OT)\",\n            },\n            {\n                \"id\": \"HARD-02\",\n                \"name\": \"Unnecessary services disabled\",\n                \"test\": \"Verify no unnecessary network services running (RDP if not needed, SMB, etc)\",\n            },\n            {\n                \"id\": \"HARD-03\",\n                \"name\": \"USB port restrictions\",\n                \"test\": \"Verify USB mass storage is blocked on HMI terminals\",\n            },\n            {\n                \"id\": \"HARD-04\",\n                \"name\": \"Application whitelisting\",\n                \"test\": \"Verify only authorized HMI applications can execute\",\n            },\n            {\n                \"id\": \"HARD-05\",\n                \"name\": \"Audit logging enabled\",\n                \"test\": \"Verify operator actions, login events, and setpoint changes are logged\",\n            },\n        ]\n\n        print(f\"\\n--- HMI HARDENING ASSESSMENT ---\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def generate_report(self):\n        \"\"\"Generate assessment report.\"\"\"\n        self.check_authentication()\n        self.check_communication_security()\n        self.check_web_hmi_security()\n        self.check_hardening()\n\n        print(f\"\\n{'='*70}\")\n        print(\"SCADA HMI SECURITY ASSESSMENT SUMMARY\")\n        print(f\"{'='*70}\")\n        print(f\"Date: {datetime.now().isoformat()}\")\n        print(f\"HMI: {self.hmi_info.get('name', 'Unknown')}\")\n        print(f\"Vendor: {self.hmi_info.get('vendor', 'Unknown')}\")\n        print(f\"Version: {self.hmi_info.get('version', 'Unknown')}\")\n        print(f\"Total Checks: {self.checks_run}\")\n        print(f\"Findings: {len(self.findings)}\")\n\n\nif __name__ == \"__main__\":\n    assessment = HMISecurityAssessment(hmi_info={\n        \"name\": \"Plant-HMI-01\",\n        \"vendor\": \"Siemens WinCC\",\n        \"version\": \"7.5 SP2\",\n        \"ip\": \"10.10.2.10\",\n        \"url\": \"https:\u002F\u002F10.10.2.10:8080\",\n        \"os\": \"Windows 10 LTSC 2021\",\n    })\n    assessment.generate_report()\n```\n\n## Key Concepts\n\n| Term | Definition |\n|------|------------|\n| HMI | Human-Machine Interface providing operators visual representation and control of industrial processes |\n| Web HMI | Browser-based HMI interface accessible via HTTP\u002FHTTPS, subject to standard web vulnerabilities |\n| Setpoint | Target value for a process variable that operators can change through the HMI; unauthorized changes can cause process upset |\n| Alarm Suppression | Attacker technique of disabling or hiding HMI alarms to mask malicious process manipulation |\n| WinCC | Siemens SCADA\u002FHMI software widely deployed in manufacturing and process industries |\n| CVE-2025-0921 | Ignition SCADA privileged file system vulnerability exploitable through malicious project uploads |\n\n## Output Format\n\n```\nHMI SECURITY ASSESSMENT REPORT\n=================================\nDate: YYYY-MM-DD\nHMI: [name] | Vendor: [vendor] | Version: [version]\n\nFINDINGS BY CATEGORY:\n  Authentication: [pass\u002Ffail count]\n  Communication: [pass\u002Ffail count]\n  Web Security: [pass\u002Ffail count]\n  Hardening: [pass\u002Ffail count]\n\nCRITICAL FINDINGS:\n  1. [finding with remediation]\n\nCOMPLIANCE STATUS:\n  IEC 62443 SL-T: [target level]\n  IEC 62443 SL-A: [achieved level]\n```\n","# Performing SCADA HMI Security Assessment\n\n## When to Use\n\n- When assessing the security posture of HMI systems in SCADA\u002FDCS environments\n- When evaluating web-based HMI interfaces for common web vulnerabilities\n- When auditing HMI authentication, authorization, and session management\n- When testing communication security between HMIs and PLCs\u002FRTUs\n- When preparing for IEC 62443 or NERC CIP compliance assessments\n\n**Do not use** for testing HMIs in active production without a maintenance window and rollback plan, for PLC-level protocol analysis (see performing-s7comm-protocol-security-analysis), or for general web application testing on non-OT systems.\n\n## Prerequisites\n\n- HMI system inventory with vendor, version, and network configuration details\n- Lab or test environment mirroring production HMI setup (preferred for active testing)\n- Authorization from plant operations for testing during maintenance windows\n- NIST SP 800-82 and IEC 62443 security requirements documentation\n- Network capture capability on HMI-to-PLC communication segment\n\n## Workflow\n\n### Step 1: Assess HMI Attack Surface\n\n```python\n#!\u002Fusr\u002Fbin\u002Fenv python3\n\"\"\"SCADA HMI Security Assessment Tool.\n\nEvaluates HMI security across authentication, communication,\nconfiguration, and web interface categories aligned with\nIEC 62443 and NIST SP 800-82 requirements.\n\"\"\"\n\nimport json\nimport sys\nfrom datetime import datetime\nfrom typing import Dict, List\n\ntry:\n    import requests\nexcept ImportError:\n    print(\"Install requests: pip install requests\")\n    sys.exit(1)\n\n\nclass HMISecurityAssessment:\n    \"\"\"Performs security assessment of SCADA HMI systems.\"\"\"\n\n    def __init__(self, hmi_info: dict):\n        self.hmi_info = hmi_info\n        self.findings = []\n        self.checks_run = 0\n        self.checks_passed = 0\n\n    def check_authentication(self):\n        \"\"\"Assess HMI authentication mechanisms.\"\"\"\n        checks = [\n            {\n                \"id\": \"AUTH-01\",\n                \"name\": \"Password complexity enforcement\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.7\",\n                \"description\": \"HMI must enforce minimum password complexity requirements\",\n                \"test\": \"Verify minimum length >= 8, complexity rules, history >= 5\",\n            },\n            {\n                \"id\": \"AUTH-02\",\n                \"name\": \"Account lockout policy\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.11\",\n                \"description\": \"HMI must lock accounts after failed login attempts\",\n                \"test\": \"Verify lockout after 5 failed attempts, lockout duration >= 15 min\",\n            },\n            {\n                \"id\": \"AUTH-03\",\n                \"name\": \"Default credentials changed\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.5\",\n                \"description\": \"All default vendor credentials must be changed\",\n                \"test\": \"Attempt login with known vendor defaults (admin\u002Fadmin, operator\u002Foperator)\",\n            },\n            {\n                \"id\": \"AUTH-04\",\n                \"name\": \"Role-based access control\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 2.1\",\n                \"description\": \"HMI must separate operator, engineer, and admin roles\",\n                \"test\": \"Verify operator role cannot access engineering functions\",\n            },\n            {\n                \"id\": \"AUTH-05\",\n                \"name\": \"Session timeout enforcement\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.12\",\n                \"description\": \"HMI sessions must time out after inactivity\",\n                \"test\": \"Verify session timeout \u003C= 15 minutes for operator, \u003C= 5 for admin\",\n            },\n            {\n                \"id\": \"AUTH-06\",\n                \"name\": \"Multi-factor authentication for remote access\",\n                \"iec62443_ref\": \"ISA-62443-3-3 SR 1.13\",\n                \"description\": \"Remote HMI access requires MFA\",\n                \"test\": \"Verify MFA is enforced for all non-local HMI connections\",\n            },\n        ]\n\n        print(f\"\\n--- AUTHENTICATION ASSESSMENT ---\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Ref: {check['iec62443_ref']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def check_communication_security(self):\n        \"\"\"Assess HMI-to-PLC communication security.\"\"\"\n        checks = [\n            {\n                \"id\": \"COMM-01\",\n                \"name\": \"Encrypted HMI-PLC communication\",\n                \"description\": \"Traffic between HMI and PLCs should use encrypted protocols (OPC UA with TLS)\",\n                \"test\": \"Capture HMI-PLC traffic and verify encryption (Wireshark TLS handshake)\",\n            },\n            {\n                \"id\": \"COMM-02\",\n                \"name\": \"HMI write command authentication\",\n                \"description\": \"Write commands from HMI to PLC should be authenticated\",\n                \"test\": \"Verify that write operations require operator confirmation\u002Fauthentication\",\n            },\n            {\n                \"id\": \"COMM-03\",\n                \"name\": \"Web HMI uses HTTPS\",\n                \"description\": \"Web-based HMI interfaces must use TLS 1.2+ with valid certificates\",\n                \"test\": \"Check TLS version, cipher suites, certificate validity\",\n            },\n            {\n                \"id\": \"COMM-04\",\n                \"name\": \"No cleartext protocols in use\",\n                \"description\": \"Telnet, FTP, HTTP must not be used for HMI access or management\",\n                \"test\": \"Port scan HMI for cleartext protocol services\",\n            },\n        ]\n\n        print(f\"\\n--- COMMUNICATION SECURITY ASSESSMENT ---\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def check_web_hmi_security(self):\n        \"\"\"Assess web-based HMI for common web vulnerabilities.\"\"\"\n        hmi_url = self.hmi_info.get(\"url\", \"\")\n        if not hmi_url:\n            print(f\"\\n  [SKIP] No web HMI URL provided\")\n            return\n\n        checks = [\n            {\n                \"id\": \"WEB-01\",\n                \"name\": \"Cross-Site Scripting (XSS)\",\n                \"owasp\": \"A7:2017\",\n                \"test\": \"Test input fields with XSS payloads in tag names, alarm messages\",\n            },\n            {\n                \"id\": \"WEB-02\",\n                \"name\": \"Cross-Site Request Forgery (CSRF)\",\n                \"owasp\": \"A8:2013\",\n                \"test\": \"Verify CSRF tokens on state-changing operations (setpoint changes)\",\n            },\n            {\n                \"id\": \"WEB-03\",\n                \"name\": \"Insecure Direct Object References\",\n                \"owasp\": \"A4:2013\",\n                \"test\": \"Manipulate URL parameters to access other users HMI views\",\n            },\n            {\n                \"id\": \"WEB-04\",\n                \"name\": \"Security Headers\",\n                \"test\": \"Verify X-Frame-Options, CSP, X-Content-Type-Options headers\",\n            },\n            {\n                \"id\": \"WEB-05\",\n                \"name\": \"Privileged file system access (CVE-2025-0921)\",\n                \"test\": \"Check Ignition SCADA for privileged file system vulnerability via project files\",\n            },\n        ]\n\n        print(f\"\\n--- WEB HMI SECURITY ASSESSMENT ---\")\n        print(f\"  Target: {hmi_url}\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def check_hardening(self):\n        \"\"\"Assess HMI operating system and application hardening.\"\"\"\n        checks = [\n            {\n                \"id\": \"HARD-01\",\n                \"name\": \"OS patch level\",\n                \"test\": \"Verify HMI OS is patched within SLA (typically 90 days for OT)\",\n            },\n            {\n                \"id\": \"HARD-02\",\n                \"name\": \"Unnecessary services disabled\",\n                \"test\": \"Verify no unnecessary network services running (RDP if not needed, SMB, etc)\",\n            },\n            {\n                \"id\": \"HARD-03\",\n                \"name\": \"USB port restrictions\",\n                \"test\": \"Verify USB mass storage is blocked on HMI terminals\",\n            },\n            {\n                \"id\": \"HARD-04\",\n                \"name\": \"Application whitelisting\",\n                \"test\": \"Verify only authorized HMI applications can execute\",\n            },\n            {\n                \"id\": \"HARD-05\",\n                \"name\": \"Audit logging enabled\",\n                \"test\": \"Verify operator actions, login events, and setpoint changes are logged\",\n            },\n        ]\n\n        print(f\"\\n--- HMI HARDENING ASSESSMENT ---\")\n        for check in checks:\n            self.checks_run += 1\n            print(f\"  [{check['id']}] {check['name']}\")\n            print(f\"    Test: {check['test']}\")\n\n    def generate_report(self):\n        \"\"\"Generate assessment report.\"\"\"\n        self.check_authentication()\n        self.check_communication_security()\n        self.check_web_hmi_security()\n        self.check_hardening()\n\n        print(f\"\\n{'='*70}\")\n        print(\"SCADA HMI SECURITY ASSESSMENT SUMMARY\")\n        print(f\"{'='*70}\")\n        print(f\"Date: {datetime.now().isoformat()}\")\n        print(f\"HMI: {self.hmi_info.get('name', 'Unknown')}\")\n        print(f\"Vendor: {self.hmi_info.get('vendor', 'Unknown')}\")\n        print(f\"Version: {self.hmi_info.get('version', 'Unknown')}\")\n        print(f\"Total Checks: {self.checks_run}\")\n        print(f\"Findings: {len(self.findings)}\")\n\n\nif __name__ == \"__main__\":\n    assessment = HMISecurityAssessment(hmi_info={\n        \"name\": \"Plant-HMI-01\",\n        \"vendor\": \"Siemens WinCC\",\n        \"version\": \"7.5 SP2\",\n        \"ip\": \"10.10.2.10\",\n        \"url\": \"https:\u002F\u002F10.10.2.10:8080\",\n        \"os\": \"Windows 10 LTSC 2021\",\n    })\n    assessment.generate_report()\n```\n\n## Key Concepts\n\n| Term | Definition |\n|------|------------|\n| HMI | Human-Machine Interface providing operators visual representation and control of industrial processes |\n| Web HMI | Browser-based HMI interface accessible via HTTP\u002FHTTPS, subject to standard web vulnerabilities |\n| Setpoint | Target value for a process variable that operators can change through the HMI; unauthorized changes can cause process upset |\n| Alarm Suppression | Attacker technique of disabling or hiding HMI alarms to mask malicious process manipulation |\n| WinCC | Siemens SCADA\u002FHMI software widely deployed in manufacturing and process industries |\n| CVE-2025-0921 | Ignition SCADA privileged file system vulnerability exploitable through malicious project uploads |\n\n## Output Format\n\n```\nHMI SECURITY ASSESSMENT REPORT\n=================================\nDate: YYYY-MM-DD\nHMI: [name] | Vendor: [vendor] | Version: [version]\n\nFINDINGS BY CATEGORY:\n  Authentication: [pass\u002Ffail count]\n  Communication: [pass\u002Ffail count]\n  Web Security: [pass\u002Ffail count]\n  Hardening: [pass\u002Ffail count]\n\nCRITICAL FINDINGS:\n  1. [finding with remediation]\n\nCOMPLIANCE STATUS:\n  IEC 62443 SL-T: [target level]\n  IEC 62443 SL-A: [achieved level]\n```\n",{"name":5,"tags":24,"author":33,"domain":34,"license":14,"version":35,"nist_csf":36,"subdomain":41,"description":42,"mitre_attack":43},[25,26,27,28,29,30,31,32],"ot-security","ics","scada","hmi","security-assessment","vulnerability","iec62443","nist-800-82","mahipal","cybersecurity","1.0",[37,38,39,40],"PR.IR-01","DE.CM-01","ID.AM-05","GV.OC-02","ot-ics-security","Perform security assessments of SCADA Human-Machine Interface (HMI) systems to identify vulnerabilities in web-based HMIs, thin-client configurations, authentication mechanisms, and communication channels between HMI and PLCs, aligned with IEC 62443 and NIST SP 800-82 guidelines.\n",[44,45,46,47,48],"T1078","T1190","T1059","T0816","T0836","main","1eb986d0b0ecc180291597e08eb5a58288843536","skills\u002Fcurated_premium_skills\u002FAnthropic-Cybersecurity-Skills\u002Fskills\u002Fperforming-scada-hmi-security-assessment","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv","2026-08-25 13:16:33",{"source":8,"skillName":5,"commands":56,"prompt":66,"zipAvailable":67},[57,60,63],{"tool":58,"command":59},"npx","npx skills add vikasvardhanv\u002Fjerry_skills --skill performing-scada-hmi-security-assessment",{"tool":61,"command":62},"bunx","bunx skills add vikasvardhanv\u002Fjerry_skills --skill performing-scada-hmi-security-assessment",{"tool":64,"command":65},"pnpm","pnpm dlx skills add vikasvardhanv\u002Fjerry_skills --skill performing-scada-hmi-security-assessment","安装技能，技能地址：https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fcurated_premium_skills\u002FAnthropic-Cybersecurity-Skills\u002Fskills\u002Fperforming-scada-hmi-security-assessment\u002FSKILL.md",true,[69,73,79],{"path":70,"resourceType":70,"resourceTypeDesc":71,"sizeBytes":72,"sourceHtmlUrl":15},"LICENSE","许可证",11255,{"path":74,"resourceType":75,"resourceTypeDesc":76,"sizeBytes":77,"sourceHtmlUrl":78},"references\u002Fapi-reference.md","REFERENCE","参考文档",2601,"https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fcurated_premium_skills\u002FAnthropic-Cybersecurity-Skills\u002Fskills\u002Fperforming-scada-hmi-security-assessment\u002Freferences\u002Fapi-reference.md",{"path":80,"resourceType":81,"resourceTypeDesc":82,"sizeBytes":83,"sourceHtmlUrl":84},"scripts\u002Fagent.py","SCRIPT","脚本",6908,"https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fcurated_premium_skills\u002FAnthropic-Cybersecurity-Skills\u002Fskills\u002Fperforming-scada-hmi-security-assessment\u002Fscripts\u002Fagent.py",[86,94,101,108,115,122],{"skillNo":87,"name":88,"nameZh":6,"description":89,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":6,"repositoryNo":12,"starsCount":13,"licenseSpdxId":90,"licenseFileUrl":6,"sourceHtmlUrl":91,"categories":92,"keywords":93,"publishedAt":19},"01M7BESR1CJ3H5SP9XM8KYJZ9W","syllabus","Generates a curated supplementary reading list from any course syllabus using Consensus academic search. Grill-me intake (syllabus input format + course audience + year range) plus a grouping forcing-options checkpoint before any search runs — so the reading list matches the course's level and recency need. Parses the syllabus to extract topics and learning outcomes, searches Consensus for recent peer-reviewed papers per topic, and produces a professionally formatted .docx with clickable Consensus links, plain-language summaries calibrated to audience level, and Bloom-higher-order discussion questions tied to course learning goals. Use when the user uploads a syllabus, course outline, or curriculum document and wants supplementary readings (e.g., 'create a reading list from this syllabus', 'find recent papers for my course') — even casual mentions with a syllabus attached should trigger this skill.","MIT","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fresearch\u002Fsyllabus\u002Fskills\u002Fsyllabus\u002FSKILL.md",[],[],{"skillNo":95,"name":96,"nameZh":6,"description":97,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":6,"repositoryNo":12,"starsCount":13,"licenseSpdxId":90,"licenseFileUrl":6,"sourceHtmlUrl":98,"categories":99,"keywords":100,"publishedAt":19},"01M7BES1YA6R97W7QPMFFM1PED","pulse","Multi-source recency research skill that takes the pulse of any topic across Reddit, Hacker News, the open web, and optionally X\u002FTwitter within a configurable recent window (default 30 days). Forcing intake clarifies topic specificity, angle (trend\u002Fsentiment\u002Fproblems\u002Fopportunities\u002Fcomparison), time window, and platform scope before searching. Returns a synthesized briefing with citations, engagement metrics, and cross-platform pattern analysis. Use when the user requests multi-source recency intelligence on a topic (e.g., 'pulse on [topic]', 'what's happening with [topic]', 'what are people saying about [topic]', 'current conversation about [topic]', 'take the pulse of [topic]', 'trending: [topic]', 'find me info on [topic]'), and for competitor research, trend discovery, tool comparisons, and audience sentiment analysis.","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fresearch\u002Fpulse\u002Fskills\u002Fpulse\u002FSKILL.md",[],[],{"skillNo":102,"name":103,"nameZh":6,"description":104,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":6,"repositoryNo":12,"starsCount":13,"licenseSpdxId":90,"licenseFileUrl":6,"sourceHtmlUrl":105,"categories":106,"keywords":107,"publishedAt":19},"01M7BERNHYGY035AR00VRT03KE","patent","Patent prior-art and landscape intelligence skill — not generic patent help. Commits to one of five sub-use-cases via forcing intake (novelty search \u002F freedom-to-operate \u002F competitive landscape \u002F acquisition diligence \u002F litigation prior-art) before any search runs. Searches Google Patents, Espacenet, USPTO, and optionally Lens.org for citation-graph signals. Output is an editable Word document (.docx) with verdict, ranked closest art (claim-text extracted), CPC-class-aware landscape, family-resolved hits, geographic coverage, FTO flags where applicable, strategy recommendations, and full audit log. Use when the user asks for patent searching or analysis (e.g., 'prior art search for [invention]', 'freedom to operate analysis for [product]'). Produces search signal, not legal advice — always recommends consulting a patent attorney before filing or licensing decisions. Trademark, copyright, and trade-secret questions are out of scope.","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fresearch\u002Fpatent\u002Fskills\u002Fpatent\u002FSKILL.md",[],[],{"skillNo":109,"name":110,"nameZh":6,"description":111,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":6,"repositoryNo":12,"starsCount":13,"licenseSpdxId":90,"licenseFileUrl":6,"sourceHtmlUrl":112,"categories":113,"keywords":114,"publishedAt":19},"01M7BERCK1EAKTWW7R436WAR0J","notebooklm","Browser automation skill for controlling Google's NotebookLM. Use when the user wants anything done in NotebookLM (e.g., 'open NotebookLM', 'check my [name] notebook', 'ask my notebook about X', 'add [source] to NotebookLM', 'generate a Video Overview from my notebook', 'use NotebookLM Studio'). Handles reading and querying notebooks, adding sources (URLs, text, files, YouTube links, synthesized content), generating Studio outputs (Audio\u002FVideo Overviews, Mind Maps, Reports incl. Briefing Doc\u002FStudy Guide\u002FFAQ, Flashcards, Quiz, slide decks, infographics — discover the exact set from the live Studio panel; the UI evolves fast), and creating new notebooks. Requires browser automation environment — fails gracefully when unavailable.","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fresearch\u002Fnotebooklm\u002Fskills\u002Fnotebooklm\u002FSKILL.md",[],[],{"skillNo":116,"name":117,"nameZh":6,"description":118,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":6,"repositoryNo":12,"starsCount":13,"licenseSpdxId":90,"licenseFileUrl":6,"sourceHtmlUrl":119,"categories":120,"keywords":121,"publishedAt":19},"01M7BEQZAZAQRTXFJRY7RHV3TY","litreview","Academic literature orientation skill that searches papers via free keyless APIs (PubMed E-utilities + OpenAlex) by default — with the Consensus MCP as an optional enhancement lane when connected — builds a strategic search plan using PICO (default) or SPIDER \u002F Decomposition \u002F hybrid as fallbacks, and synthesizes findings into a formatted Word (.docx) research guide. Grill-me intake (research question specificity + framework hint + tentative depth) before the recon search; a second forcing checkpoint after Phase 2 confirms framework + sub-areas + depth before searches consume budget. Configurable depth (5\u002F10\u002F20 queries) controls coverage vs. speed. Output is a 'launching pad' — an orientation guide that lets a researcher dive in confidently, not a finished review. Use when the user starts literature-oriented research (e.g., 'litreview on [topic]', 'literature review on [topic]', 'I'm starting a literature review on X', 'I'm writing a paper on X', 'help me research X', 'I'm doing research on X', 'can you help me research X'). Do NOT use for single one-off paper searches wanting a quick list — that's a plain PubMed\u002FOpenAlex (or Consensus) query.","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fresearch\u002Flitreview\u002Fskills\u002Flitreview\u002FSKILL.md",[],[],{"skillNo":123,"name":124,"nameZh":6,"description":125,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":6,"repositoryNo":12,"starsCount":13,"licenseSpdxId":90,"licenseFileUrl":6,"sourceHtmlUrl":126,"categories":127,"keywords":128,"publishedAt":19},"01M7BEQKJ45K31QK5VRAQSVJCJ","grants","NIH grant research skill for clinical researchers. Grill-me intake (research idea + career stage + preliminary data + environment + submission posture + known institute targets) locks down the funding strategy before any search runs. Runs a 5-facet Consensus positioning analysis (with draft Significance\u002FInnovation language), maps the research to the right NIH institutes and study sections via RePORTER, finds NOSIs and funded overlap, and produces an editable Word document (.docx) with budget\u002Fscope-aware mechanism recommendations, submission timelines, and a mandatory program officer recommendation. Use when the user asks about research funding or makes any grant-related request (e.g., 'grants for [topic]', 'find grants for my research idea', 'what grants match my research', 'help me find NIH funding', 'grant opportunities for my research'). NIH-only scope — non-NIH funders (PCORI, DOD CDMRP, VA, foundations) are out of scope and flagged at intake.","https:\u002F\u002Fgithub.com\u002Fvikasvardhanv\u002Fjerry_skills\u002Fblob\u002Fmain\u002Fskills\u002Fresearch\u002Fgrants\u002Fskills\u002Fgrants\u002FSKILL.md",[],[]]