Use when correcting a refrigeration, HVAC or food storage misconception, looking up a temperature, pressure, superheat, GWP, air-change or water-treatment figure, finding the books and standards, or needing a quick-reference picker — plus the current state of the refrigerant transition and cold chain capacity. Companion to the other refrigeration and climate control skills.

License 许可
MIT
最近更新
2026-11-15
Stars
★ 5
Forks
3

01 前言 Front Matter

name
hvacr-reference
description
Use when correcting a refrigeration, HVAC or food storage misconception, looking up a temperature, pressure, superheat, GWP, air-change or water-treatment figure, finding the books and standards, or needing a quick-reference picker — plus the current state of the refrigerant transition and cold chain capacity. Companion to the other refrigeration and climate control skills.

03 SKILL.md 正文

Refrigeration and Climate Control: What's Live, Misconceptions, Numbers, and Books

Part 5 of 5 of the Refrigeration, AC, Climate Control and Food/Water Storage reference (plugin refrigeration-ac-climate-control-food-water), covering §25–§30. Sibling skills: hvacr-cycle-components-refrigerants-and-diagnosis (§0–§6), hvacr-load-calculation-air-humidity-and-heat-pumps (§7–§13), hvacr-cold-chain-temperature-limits-and-validation (§14–§21), hvacr-preservation-water-storage-and-treatment (§22–§24). Section numbers are shared across the set; a reference written as §N → skill points into that sibling skill.

Currency: The thermodynamics is permanent. Two areas moved. See §25 for the refrigerant transition, and cold chain capacity and food loss.

⚠️ Everything here is one idea in different clothes: MOVING HEAT from where you don't want it to where you don't care, and doing it reliably enough that the thing being cooled stays safe. Complements a thermodynamics reference (the cycle theory and psychrometrics) and a cooking/cleaning reference (food safety at the point of use).

⚠️ GOTCHA boxes mark the diagnoses people get backwards, and the safety limits that aren't negotiable.

⚠️ Safety, stated once and up front: ⚠️ refrigerant systems hold high pressure and can cause frostbite and asphyxiation; A2L refrigerants are mildly flammable and require specific tooling and training (§25.1); ammonia is toxic; and the food temperature limits in §16 → hvacr-cold-chain-temperature-limits-and-validation are not guidance, they are the reason people don't die. ⚠️ Refrigerant handling is a certified activity in most jurisdictions — venting is illegal and recovery is mandatory.

The three ideas that organize this document:

  1. ⚠️ SUPERHEAT and SUBCOOLING are how you see inside a sealed system (§5 → hvacr-cycle-components-refrigerants-and-diagnosis). Everything else in diagnosis is guessing.
  2. ⚠️ The cold chain is only as good as its worst link, and the worst link is almost always a HANDOFF (§15 → hvacr-cold-chain-temperature-limits-and-validation, §20 → hvacr-cold-chain-temperature-limits-and-validation). Not the warehouse and not the truck — the dock, the delay, the unmonitored gap.
  3. ⚠️ Preservation is about denying microbes ONE of their requirements (§22 → hvacr-preservation-water-storage-and-treatment). Temperature is only one option; water activity, pH, oxygen and competition are the others, and the durable methods stack several.

§25. What's Live — verified August 2026

25.1 ⚠️ The refrigerant transition — the biggest change since R-22

⚠️ If you buy, service or specify cooling equipment, this changes what you can install and what service costs.

  • ⚠️ The driver is the AIM Act in the US and the revised F-Gas Regulation in the EU, both implementing the Kigali Amendment's HFC phasedown. ⚠️ The US target is reported as an 85% reduction in HFCs by 2036; the EU quota schedule runs from 100% of the 2015 baseline down to 5% by 2030.
  • ⚠️ The chemistry: R-410A has a GWP around 2,088. ⚠️ Its replacements are R-32 (GWP ~675) and R-454B (GWP ~466, an HFC blend of R-32 and R-1234yf) — both roughly two-thirds lower impact while matching efficiency. ⚠️ For residential and light commercial comfort cooling the GWP limit is 700, which is what excludes R-410A.
  • ⚠️ Both replacements are A2L — MILDLY flammable — and this is the practical change for anyone servicing equipment. ⚠️ A2L is defined by a burning velocity below 10 cm/s versus over 100 cm/s for propane (A3). ⚠️ Reported practical behaviour: an A2L leak in a typical room rarely reaches flammable concentration before air movement dilutes it, and ignited flame often self-extinguishes. ⚠️ Equipment must meet UL 60335-2-40, technicians need A2L-specific certification and tooling, and charge limits and leak detection apply.
  • ⚠️ Sector-specific EU limits are tiered rather than a single number: reported GWP 2,500 as the outer limit for stationary refrigeration, 750 for new single-split AC, and 150 for self-contained commercial refrigeration and — from 2029 — most residential AC. ⚠️ That last tier is low enough that A2L HFC blends won't clear it, pointing toward R-290 (propane) and other naturals.

⚠️ GOTCHA — the sources CONFLICT on the R-410A installation deadline, and this matters if you're specifying equipment right now. ⚠️ Multiple 2026 sources state the EPA Technology Transitions Rule banned installation of new high-GWP residential systems from 1 January 2026. ⚠️ But at least one source reports an EPA final rule in May 2026 that EXTENDED the installation deadline for pre-manufactured inventory, allowing contractors to still install pre-2025 R-410A stock, and another describes a "latest EPA action" that has been misread as reverting to the R-410A era. ⚠️ The stable facts: manufacture of new R-410A equipment in the covered category is restricted, new equipment is A2L, and SERVICING existing R-410A systems remains legal indefinitely. ⚠️ The unstable fact is the exact cut-off for installing existing inventory — verify against the EPA directly before relying on it.

⚠️ The economics is the part that reaches everyone: ⚠️ quota reduction has driven reported R-410A price increases of roughly 40–70% from 2022 levels, and the phasedown means that continues structurally regardless of supply conditions. ⚠️ The practical consequence: an expensive repair on an older R-410A system is a worse bet each year, and the calculus for repair-vs-replace has shifted. ⚠️ Note also that you CANNOT retrofit an A2L into an R-410A system (§3 → hvacr-cycle-components-refrigerants-and-diagnosis). ⚠️ Compliance obligations tightened too: ⚠️ annual leak inspections for covered systems are reported starting January 2026, with automatic leak detection required on systems over 1,500 lb charge.

25.2 ⚠️ The cold chain gap: what missing refrigeration actually costs

⚠️ The number that reframes §15 → hvacr-cold-chain-temperature-limits-and-validation from a logistics concern into a food-security one.

  • ⚠️ The UNEP–FAO Sustainable Food Cold Chains report finds that lack of effective refrigeration directly caused the loss of 526 million tonnes of food production — about 12% of the global total (2017 figures). ⚠️ Reported as enough to feed roughly 1 billion people.
  • ⚠️ Context: an estimated 14% of food produced for human consumption is LOST before reaching the consumer and a further 17% WASTED, ⚠️ with the loss costing a reported $936 billion annually.
  • ⚠️ The emissions picture cuts both ways, which is the tension worth naming. ⚠️ The food cold chain is responsible for around 4% of total global greenhouse gas emissions when both the cooling technology and the food loss from missing refrigeration are counted — reported as roughly 20% direct refrigerant emissions and 80% from electricity generation. ⚠️ So building cold chain adds emissions AND avoids the larger emissions from lost food; the answer is efficient, low-GWP cold chain rather than either extreme.
  • ⚠️ The distribution is what matters: post-harvest loss reportedly reduces the income of 470 million small-scale farmers by around 15%, mainly in developing countries; African post-harvest losses are reported at 30%+ for fresh produce; ⚠️ and low-income food-deficit countries account for a reported ~22% of world food loss.
  • ⚠️ Health side: ⚠️ the WHO has estimated nearly 25% of liquid vaccines are wasted each year, primarily from broken cold chains (§21 → hvacr-cold-chain-temperature-limits-and-validation).

⚠️ GOTCHA — treat these figures as directionally solid and numerically soft, and the literature says so itself. ⚠️ A peer-reviewed analysis notes that FAO food loss and waste data are "limited and in many cases inconsistent and uncertain due to evolving definitions, varying tracking and reporting methodologies, and data access and quality limitations" — and that projected losses don't align well with theoretical food degradation models. ⚠️ The 526 Mt / 12% figure is widely repeated because it comes from an authoritative source, not because it has been independently replicated. ⚠️ The robust claim is that the gap is large and concentrated in low-income countries; the precise magnitude is not settled.

⚠️ Where the practical progress is: ⚠️ decentralized solar-powered cold storage at the farm and market level (ColdHubs and similar operators) targets the FIRST link — §15 → hvacr-cold-chain-temperature-limits-and-validation's precooling — which is where the leverage is highest, rather than the trunk logistics that attract more attention.


§26. Misconceptions

Misconception Correction
The compressor makes the cold ⚠️ Latent heat in the evaporator does (§1 → hvacr-cycle-components-refrigerants-and-diagnosis)
Systems consume refrigerant ⚠️ They're sealed. Low means a LEAK (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
Low on refrigerant, so add some ⚠️ Check airflow first; find the leak (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
You can drop in a different refrigerant ⚠️ Pressures, oil, materials, safety design all differ (§3 → hvacr-cycle-components-refrigerants-and-diagnosis)
Charge by superheat always ⚠️ TXV/EEV systems charge by SUBCOOLING (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
A bigger AC is safer ⚠️ Short-cycles, won't dehumidify, wears out (§7 → hvacr-load-calculation-air-humidity-and-heat-pumps, §9 → hvacr-load-calculation-air-humidity-and-heat-pumps)
An iced coil means low charge ⚠️ Airflow first — filter, coil, blower (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
High-MERV filter is a free upgrade ⚠️ Pressure drop cuts airflow. Check ESP (§10 → hvacr-load-calculation-air-humidity-and-heat-pumps)
Heat pumps don't work in cold ⚠️ Modern cold-climate units do; watch the backup (§11 → hvacr-load-calculation-air-humidity-and-heat-pumps)
The heat pump is broken — it's steaming ⚠️ That's a defrost cycle (§11 → hvacr-load-calculation-air-humidity-and-heat-pumps)
COP over 1 breaks physics ⚠️ You're moving heat, not making it (§11 → hvacr-load-calculation-air-humidity-and-heat-pumps)
Deep setback saves on a heat pump ⚠️ Recovery triggers resistance backup (§12 → hvacr-load-calculation-air-humidity-and-heat-pumps)
Cold stops spoilage ⚠️ Slows it. Enzymatic and chemical continue (§14 → hvacr-cold-chain-temperature-limits-and-validation)
If it stayed cold it's safe ⚠️ Listeria grows at fridge temperatures (§14 → hvacr-cold-chain-temperature-limits-and-validation)
Freezing kills bacteria ⚠️ Makes them dormant (§16 → hvacr-cold-chain-temperature-limits-and-validation)
Thaw on the counter ⚠️ Surface enters the danger zone. Fridge or cold water (§16 → hvacr-cold-chain-temperature-limits-and-validation)
A big pot cools fine in the fridge ⚠️ It won't meet the cooling rule. Shallow pans (§16 → hvacr-cold-chain-temperature-limits-and-validation)
Colder is always better for produce ⚠️ Chilling injury — bananas, tomatoes, basil (§18 → hvacr-cold-chain-temperature-limits-and-validation)
A reefer will cool the load down ⚠️ It MAINTAINS. Pre-cool before loading (§19 → hvacr-cold-chain-temperature-limits-and-validation)
Supply air temperature is the number ⚠️ Pulp temperature is (§19 → hvacr-cold-chain-temperature-limits-and-validation, §20 → hvacr-cold-chain-temperature-limits-and-validation)
Freezer burn is a safety issue ⚠️ Sublimation. Quality only; fix the packaging (§14 → hvacr-cold-chain-temperature-limits-and-validation, §17 → hvacr-cold-chain-temperature-limits-and-validation)
Boiling water canning works for vegetables ⚠️ Low-acid REQUIRES pressure canning (§22 → hvacr-preservation-water-storage-and-treatment)
Garlic in oil keeps on the shelf ⚠️ Anaerobic, low-acid — botulism risk (§22 → hvacr-preservation-water-storage-and-treatment)
Vacuum packing makes it shelf-stable ⚠️ It selects for anaerobes (§22 → hvacr-preservation-water-storage-and-treatment)
Boiling purifies water ⚠️ Kills pathogens; CONCENTRATES chemicals (§24 → hvacr-preservation-water-storage-and-treatment)
A carbon filter makes water safe ⚠️ Taste and organics; not salts or microbes reliably (§24 → hvacr-preservation-water-storage-and-treatment)
UV is a complete solution ⚠️ No residual, and turbidity shields organisms (§24 → hvacr-preservation-water-storage-and-treatment)
A bigger water tank is better ⚠️ Stagnation loses residual and grows biofilm (§23 → hvacr-preservation-water-storage-and-treatment)
R-410A is banned outright ⚠️ Servicing stays legal; manufacture is restricted (§25.1)
A2L is dangerously flammable ⚠️ <10 cm/s burning velocity vs >100 for propane (§25.1)

§27. Numbers

⚠️ DANGER ZONE        5–60°C (41–140°F) · ⚠️ 2-hour / 4-hour rule
⚠️ Refrigeration      ≤5°C (41°F) · ⚠️ Freezer −18°C (0°F)
⚠️ Cooling rule       60→21°C in 2h, then 21→5°C in 4h
⚠️ Hot holding        ≥60°C (140°F) · poultry cooked to 74°C (165°F)
⚠️ Pharma             2–8°C · −20°C frozen · −60 to −80°C ultra-cold
⚠️ Water activity     bacteria stop ~0.91 · moulds ~0.80 · nothing ~0.60
⚠️ Canning pH line    4.6 (⚠️ below = water bath; above = PRESSURE)
⚠️ Respiration rate   roughly doubles per +10°C
⚠️ Indoor RH target   40–60%
⚠️ Evacuation target  ~500 microns with a decay test
⚠️ Boil for water     1 min rolling (⚠️ 3 min at altitude)
⚠️ Emergency water    ~4 L (1 gal) per person per day
⚠️ Legionella growth  ~20–45°C in stagnant water
GWP  ⚠️ R-410A ~2,088 · R-32 ~675 · R-454B ~466 · ⚠️ residential limit 700
⚠️ A2L burning velocity  <10 cm/s (vs >100 cm/s for A3 propane)
⚠️ EU quota          100% (2015 base) → 5% by 2030 · US −85% by 2036
⚠️ R-410A price      reported +40–70% vs 2022
⚠️ Food lost to missing refrigeration  526 Mt ≈ 12% of production (2017)
⚠️ Food cold chain emissions  ~4% of global GHG

§28. Books and Standards

Source Why
ASHRAE Handbook (Fundamentals / Refrigeration / HVAC Systems / Applications) ⚠️ The reference. Four volumes, one per year of rotation
ASHRAE 34 ⚠️ Refrigerant designation and safety classification (§3 → hvacr-cycle-components-refrigerants-and-diagnosis)
ASHRAE 15 Safety standard for refrigeration systems
ASHRAE 62.1 / 62.2 Ventilation (§10 → hvacr-load-calculation-air-humidity-and-heat-pumps)
ASHRAE 188 ⚠️ Legionella water management (§10 → hvacr-load-calculation-air-humidity-and-heat-pumps, §23 → hvacr-preservation-water-storage-and-treatment)
ACCA Manual J / S / D ⚠️ Load, equipment selection, ducts — §7 → hvacr-load-calculation-air-humidity-and-heat-pumps, §8 → hvacr-load-calculation-air-humidity-and-heat-pumps
UL 60335-2-40 ⚠️ The A2L equipment standard (§25.1)
Althouse, Turnquist & Bracciano Modern Refrigeration and Air Conditioning — ⚠️ the trade standard
FDA Food Code ⚠️ §16 → hvacr-cold-chain-temperature-limits-and-validation's limits, authoritative
USDA / NCHFP ⚠️ Tested home preservation recipes — §22 → hvacr-preservation-water-storage-and-treatment. Use these, not blogs
IIR (International Institute of Refrigeration) Cold chain technical guidance
WHO / PQS ⚠️ Vaccine cold chain equipment standards (§21 → hvacr-cold-chain-temperature-limits-and-validation)
EPA Section 608 / F-Gas guidance ⚠️ §25.1 — verify current status directly

§29. Quick Reference

29.1 Diagnostic picker

Symptom Where
Not cooling enough ⚠️ Superheat + subcooling before anything else (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
High superheat, low subcooling ⚠️ Undercharge — find the leak (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
Low superheat, high subcooling ⚠️ Overcharge (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
Both high ⚠️ Restriction (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
Iced evaporator ⚠️ Airflow first (§5 → hvacr-cycle-components-refrigerants-and-diagnosis, §8 → hvacr-load-calculation-air-humidity-and-heat-pumps)
High head pressure ⚠️ Dirty condenser, overcharge, non-condensables (§5 → hvacr-cycle-components-refrigerants-and-diagnosis)
Cold but clammy building ⚠️ Oversized, short-cycling, no dehumidification (§7 → hvacr-load-calculation-air-humidity-and-heat-pumps, §9 → hvacr-load-calculation-air-humidity-and-heat-pumps)
Some rooms won't condition ⚠️ Duct design, ESP, return path (§8 → hvacr-load-calculation-air-humidity-and-heat-pumps)
Heat pump bills disappointing ⚠️ Resistance backup running. Check controls (§11 → hvacr-load-calculation-air-humidity-and-heat-pumps)
Water dripping from the air handler ⚠️ Condensate drain or trap (§9 → hvacr-load-calculation-air-humidity-and-heat-pumps)
Produce spoiling fast ⚠️ Precooling and ethylene separation (§15 → hvacr-cold-chain-temperature-limits-and-validation, §18 → hvacr-cold-chain-temperature-limits-and-validation)
Load arrived warm ⚠️ Was it pre-cooled? Airflow blocked? Door openings? (§19 → hvacr-cold-chain-temperature-limits-and-validation)
Frozen product weeping on thaw ⚠️ Frozen too slowly, or storage fluctuated (§17 → hvacr-cold-chain-temperature-limits-and-validation)
Is this excursion a problem? ⚠️ Cumulative time, and MKT for pharma (§15 → hvacr-cold-chain-temperature-limits-and-validation, §20 → hvacr-cold-chain-temperature-limits-and-validation)
Preserving without a fridge ⚠️ Pick a barrier: a_w, pH, heat, oxygen (§22 → hvacr-preservation-water-storage-and-treatment)
Is this water safe? ⚠️ Match barrier to threat; taste ≠ safe (§24 → hvacr-preservation-water-storage-and-treatment)

29.2 Cold chain checklist

  • [ ] ⚠️ Product AT temperature before loading — the unit maintains (§19 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] Precooling as fast as possible after harvest (§15 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] ⚠️ Airflow path unobstructed; load within the red line (§19 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] Ethylene producers separated from sensitive product (§18 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] ⚠️ Chilling-injury-sensitive items NOT refrigerated (§18 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] ⚠️ Sensors placed where mapping found the worst case (§20 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] Handoffs and dock time monitored, not just endpoints (§15 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] ⚠️ Pulp temperature measured, not just supply air (§19 → hvacr-cold-chain-temperature-limits-and-validation)
  • [ ] Excursions assessed cumulatively (§15 → hvacr-cold-chain-temperature-limits-and-validation, §20 → hvacr-cold-chain-temperature-limits-and-validation)

§30. Method

§1–§24 → hvacr-cycle-components-refrigerants-and-diagnosis, hvacr-load-calculation-air-humidity-and-heat-pumps, hvacr-cold-chain-temperature-limits-and-validation, hvacr-preservation-water-storage-and-treatment rests on settled thermodynamics, established trade practice and public-health standards — the vapour-compression cycle, superheat and subcooling diagnosis, psychrometric humidity control, the FDA Food Code limits, water activity and pH thresholds, and standard water treatment barriers. ⚠️ None of it needed verification; the botulism pH line and the danger zone are not going to move.

Two searches were run in August 2026, on the refrigerant transition and the cold chain gap — ⚠️ the first because it changes what you can legally install and what service costs, the second because it reframes §15 → hvacr-cold-chain-temperature-limits-and-validation from logistics into food security.

Confidence. High in §5 → hvacr-cycle-components-refrigerants-and-diagnosis, which is the section I'd most want read. ⚠️ Superheat and subcooling are the only way to see inside a sealed system, and the single most useful correction in this document is that a system does not consume refrigerant — "low on refrigerant" means a leak, and most such calls are actually airflow problems. High in §16 → hvacr-cold-chain-temperature-limits-and-validation and §22 → hvacr-preservation-water-storage-and-treatment's limits, which are public-health standards with fatal consequences attached, and I've stated them as rules rather than guidance.

High on §25.1's chemistry and direction — R-410A at GWP ~2,088 replaced by R-32 (~675) and R-454B (~466) against a 700 GWP limit for residential comfort cooling, both A2L, requiring UL 60335-2-40 equipment and A2L technician certification. ⚠️ These recur consistently across every source. ⚠️ But I've flagged a genuine conflict rather than papering over it: sources disagree on the R-410A INSTALLATION deadline, with several stating a 1 January 2026 ban and at least one reporting a May 2026 EPA final rule extending the deadline for pre-manufactured inventory. ⚠️ Much of this material comes from HVAC vendors, contractors and CMMS companies with commercial interests in the transition, so I anchored on the parts they all agree about and marked the rest as reported. Verify the installation cut-off against EPA directly.

Moderate on §25.2's magnitudes, and the caveat is in the section rather than hidden here. ⚠️ The 526 Mt / 12% figure comes from a UNEP–FAO report and is repeated widely because of its source's authority — but a peer-reviewed analysis explicitly notes that FAO food loss data are inconsistent and uncertain due to evolving definitions and methodologies, and that projections don't align well with degradation models. ⚠️ The robust claims are that the gap is large, concentrated in low-income countries, and that the emissions trade-off runs both ways — building cold chain emits, and missing cold chain emits more through lost food. The precise tonnage is not independently replicated and I would not use it as a load-bearing figure in an argument.

04 同仓库更多 Skills

the-vibey-project
the-vibey-project/vibey

white-paper-writing

Use when writing white papers, technical reports, policy documents, thought leadership pieces, or any long-form authoritative document. Triggers on requests to write, structure, outline, or review white papers, technical reports, position papers, policy briefs, or evidence-driven arguments. Also use for B2B content marketing strategy, technical documentation requiring authority, academic-style reports, or any document that must educate while persuading. Use when someone asks "how should I structure this" for a long-form document.

★ 5
the-vibey-project
the-vibey-project/vibey

prose-technical-mechanics

Use when editing or writing prose at a technical/mechanical level: choosing between Anglo-Saxon and Latinate diction, placing information in topic vs stress positions, writing periodic vs cumulative sentences, handling sentence rhythm, punctuation as logic, transitions, paragraph structure, or phonesthetics. Use when someone wants to understand WHY prose works or doesn't, not just surface-level style advice. Triggers on word choice, sentence structure, emphasis, rhythm, diction, or any deep writing mechanics question.

★ 5
the-vibey-project
the-vibey-project/vibey

prose-mechanics

Use when writing, editing, or analyzing prose style; when trying to avoid generic AI-sounding writing; when applying specific prose styles such as journalistic, academic, narrative, KJV biblical, Hemingway plain, Latinate/Jamesian, Orwellian, Augustan, Victorian, Early Modern (Bacon, Browne, Milton), or free indirect discourse; or when coaching someone on writing voice and mechanics. Triggers on any request to improve, analyze, or write in a specific prose style, to fix "AI-sounding" writing, to make prose more vivid or concrete, to vary sentence rhythm, or to understand how a particular writer achieves their effects.

★ 5
the-vibey-project
the-vibey-project/vibey

narrative-structure

Use when structuring stories, pitches, presentations, white papers, or any persuasive narrative; analyzing the hero's journey in fiction or non-fiction; applying StoryBrand for business communication; designing narrative arcs for thought leadership; or understanding Vogler, Snyder, Propp, or Campbell frameworks. Triggers on any narrative structure, storytelling, pitch structure, StoryBrand, hero's journey, three-act structure, Freytag, Save the Cat, narrative arc, or "how should I structure this story/pitch/presentation" request.

★ 5
the-vibey-project
the-vibey-project/vibey

legal-brief-writing

Use when writing legal briefs, motions, or any court filing; when analyzing judicial cognition and persuasion; when applying elite brief-writing techniques from Roberts, Clement, Kagan, Garner; or when structuring legal arguments for maximum persuasion. Also use for autistic/neurodivergent advocates who need to understand how their natural communication style maps to elite legal advocacy. Triggers on any legal writing, brief drafting, motion preparation, or legal argument structuring request.

★ 5
the-vibey-project
the-vibey-project/vibey

journal-publishability-criteria

Use whenever a research paper, article or preprint is being written, revised, reviewed or published, and specifically before every publication of docs/paper.md. Covers what legitimate journals actually gate on, in order of gating — the editor's desk screen (scope, novelty, package problems), what reviewers judge (methodological soundness, claims the evidence can carry, statistical and qualitative reporting), EQUATOR reporting guidelines, the ICMJE authorship criteria, COPE's view of text recycling, the near-universal generative-AI policy (no AI author, disclosure, author responsibility), TOP 2025 transparency standards, how to verify a journal is legitimate, submitting without an institution, and a pre-submission checklist. Triggers on requests to evaluate, review, prepare or submit a paper, to judge publishability, to write a declarations or data-availability section, to disclose AI use, or to check a journal.

★ 5