[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"skill:01M7ARMH8F2TSDJNG4T2M218MB":3,"skill-same:01M7ARMH8F2TSDJNG4T2M218MB":48},{"skillNo":4,"name":5,"nameZh":6,"description":7,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":16,"categories":17,"keywords":18,"publishedAt":19,"linkOnly":20,"markdownContent":21,"markdownBody":22,"frontMatter":23,"refName":24,"commitSha":25,"skillDirectory":26,"forksCount":27,"repositoryHtmlUrl":28,"repositoryHomepageUrl":29,"ownerHtmlUrl":30,"ownerBlogUrl":31,"ownerDescription":32,"updatedAt":33,"install":34,"resources":47},"01M7ARMH8F2TSDJNG4T2M218MB","hvacr-load-calculation-air-humidity-and-heat-pumps",null,"Use for HVAC design and troubleshooting: load calculation and why rule-of-thumb sizing fails, air distribution, duct sizing and static pressure, humidity control and the sensible versus latent split, ventilation and indoor air quality, heat pumps including cold-climate performance and defrost, controls and staging, and the building envelope that sets the load in the first place.","the-vibey-project\u002Fvibey","the-vibey-project","https:\u002F\u002Favatars.githubusercontent.com\u002Fu\u002F329298758?v=4","01M7AJHGZ9722CTJ4JNQZVRH0Q","the vibey project","01M7AJHGZVMG2K7TGXQ6XFHVG3",5,"MIT","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Frefrigeration-ac-climate-control-food-water\u002Fskills\u002Fhvacr-load-calculation-air-humidity-and-heat-pumps\u002FSKILL.md",[],[],"2026-11-15 14:19:17",false,"---\nname: hvacr-load-calculation-air-humidity-and-heat-pumps\ndescription: \"Use for HVAC design and troubleshooting: load calculation and why rule-of-thumb sizing fails, air distribution, duct sizing and static pressure, humidity control and the sensible versus latent split, ventilation and indoor air quality, heat pumps including cold-climate performance and defrost, controls and staging, and the building envelope that sets the load in the first place.\"\n---\n\n# Refrigeration and Climate Control: Load Calculation, Air Distribution, Humidity Control, Ventilation, Heat Pumps, Controls, and the Building Envelope\n\n> **Part 2 of 5** of the *Refrigeration, AC, Climate Control and Food\u002FWater Storage* reference (plugin `refrigeration-ac-climate-control-food-water`), covering §7–§13. Sibling skills: `hvacr-cycle-components-refrigerants-and-diagnosis` (§0–§6), `hvacr-cold-chain-temperature-limits-and-validation` (§14–§21), `hvacr-preservation-water-storage-and-treatment` (§22–§24), `hvacr-reference` (§25–§30). Section numbers are shared across the set; a reference written as §N → `skill` points into that sibling skill.\n>\n> **Currency:** The thermodynamics is permanent. Two areas moved. See §25 → `hvacr-reference` for the refrigerant transition, and cold chain capacity and food loss.\n\n> **⚠️ Everything here is one idea in different clothes: MOVING HEAT from where you don't\n> want it to where you don't care, and doing it reliably enough that the thing being\n> cooled stays safe.** **Complements a thermodynamics reference (the cycle theory and\n> psychrometrics) and a cooking\u002Fcleaning reference (food safety at the point of use).**\n>\n> **⚠️ GOTCHA** boxes mark the diagnoses people get backwards, and the safety limits that\n> aren't negotiable.\n>\n> **⚠️ Safety, stated once and up front:** ⚠️ **refrigerant systems hold high pressure and\n> can cause frostbite and asphyxiation; A2L refrigerants are mildly flammable and require\n> specific tooling and training (§25.1 → `hvacr-reference`); ammonia is toxic; and the food temperature limits\n> in §16 → `hvacr-cold-chain-temperature-limits-and-validation` are not guidance, they are the reason people don't die.** **⚠️ Refrigerant handling\n> is a certified activity in most jurisdictions — venting is illegal and recovery is\n> mandatory.**\n>\n> **The three ideas that organize this document:**\n> 1. **⚠️ SUPERHEAT and SUBCOOLING are how you see inside a sealed system** (§5 → `hvacr-cycle-components-refrigerants-and-diagnosis`).\n>    **Everything else in diagnosis is guessing.**\n> 2. **⚠️ The cold chain is only as good as its worst link, and the worst link is almost\n>    always a HANDOFF** (§15 → `hvacr-cold-chain-temperature-limits-and-validation`, §20 → `hvacr-cold-chain-temperature-limits-and-validation`). **Not the warehouse and not the truck — the dock, the\n>    delay, the unmonitored gap.**\n> 3. **⚠️ Preservation is about denying microbes ONE of their requirements** (§22 → `hvacr-preservation-water-storage-and-treatment`).\n>    **Temperature is only one option; water activity, pH, oxygen and competition are the\n>    others, and the durable methods stack several.**\n\n---\n\n## §7. Load Calculation\n\n**⚠️ Sizing by rule of thumb is the most common and most damaging HVAC error.**\n```\n⚠️ SENSIBLE LOAD  temperature — conduction through envelope, solar gain,\n   infiltration, internal gains (people, lighting, equipment)\n⚠️ LATENT LOAD    moisture — occupants, infiltration, cooking, process\n⚠️ SHR (sensible heat ratio) = sensible \u002F total. ⚠️ THE number that\n   determines whether equipment will control humidity (§9)\n⚠️ DESIGN CONDITIONS  chosen percentile, not the record extreme —\n   deliberately, because sizing for the worst hour ruins the other 8,759\n⚠️ METHOD  ACCA Manual J (residential) \u002F ASHRAE methods; ⚠️ Manual S for\n   equipment selection and Manual D for ducts\n```\n> **⚠️ GOTCHA — an OVERSIZED air conditioner performs worse, not better, and this is\n> counterintuitive to almost every homeowner.** ⚠️ **It satisfies the thermostat quickly and\n> short-cycles, which means it never runs long enough to dehumidify** (§9) — **producing a\n> cold, clammy building.** **⚠️ It also wears the compressor with frequent starts and\n> delivers worse efficiency than its rating.** **⚠️ \"Bigger to be safe\" is exactly backwards.**\n\n---\n\n## §8. Air Distribution\n\n**⚠️ Duct design**: **friction rate, equal friction and static regain methods, ⚠️ and the\nfact that flexible duct has dramatically higher resistance than smooth metal — and\ncompressed or kinked flex is a common, invisible capacity killer.**\n**⚠️ External static pressure is the vital sign of an air system** — ⚠️ **measure it; high\nESP means the blower is fighting the ductwork and airflow is below design, which shows up\nas §5 → `hvacr-cycle-components-refrigerants-and-diagnosis`'s iced evaporator.**\n**⚠️ Duct leakage in unconditioned space is a large and common loss**; **⚠️ sealing and\ninsulating ducts frequently beats equipment upgrades on cost-effectiveness.**\n**⚠️ Return path matters as much as supply**: ⚠️ **a closed bedroom door with no return path\npressurizes the room, and the air finds its way out through the envelope.**\n**Air changes per hour, throw and diffuser selection, balancing dampers, and ⚠️ VAV vs\nconstant volume.**\n\n---\n\n## §9. ⚠️ Humidity Control\n\n**⚠️ The half of comfort that equipment sizing routinely ignores.**\n```\n⚠️ Cooling coils dehumidify by condensing moisture — which requires the\n   coil surface to be BELOW the DEW POINT and requires RUN TIME\n⚠️ SHORT CYCLING = NO DEHUMIDIFICATION (§7). This is the mechanism\n⚠️ VARIABLE-SPEED equipment dehumidifies far better because it runs\n   longer at lower capacity\n⚠️ LOWER airflow across the coil = colder coil = MORE latent removal\n   and less sensible capacity — the standard trade\n⚠️ REHEAT  overcool to dehumidify, then reheat. Effective and energy-hungry\n⚠️ DEDICATED DEHUMIDIFIER or DESICCANT for high latent loads\n```\n**⚠️ Target range roughly 40–60% RH**: ⚠️ **below ~30% causes static, respiratory\ndiscomfort and wood shrinkage; above ~60% supports mould, dust mites and condensation.**\n**⚠️ Condensation control is a building-physics problem**: ⚠️ **surfaces below the dew point\nwill wet, so the failure appears at thermal bridges, uninsulated pipes and window\nframes** — **and the fix is usually insulation or ventilation, not a bigger AC.**\n**⚠️ Condensate management**: ⚠️ **blocked drains and clogged traps cause a large share of\nwater-damage callbacks; float switches are cheap insurance.**\n\n---\n\n## §10. Ventilation and Indoor Air Quality\n\n**⚠️ Ventilation dilutes; filtration removes; source control beats both.**\n**Rates per ASHRAE 62.1\u002F62.2; ⚠️ CO₂ as a PROXY for ventilation adequacy (⚠️ it's a\ntracer for occupant-generated pollutants, not itself the hazard at typical indoor\nlevels), demand-controlled ventilation.**\n**⚠️ Filtration**: **MERV and the equivalences to ISO\u002FEN ratings; ⚠️ HEPA; and ⚠️ the\ncritical caveat that fitting a high-MERV filter to a system not designed for its pressure\ndrop reduces airflow and can cause §5 → `hvacr-cycle-components-refrigerants-and-diagnosis`'s problems.** **Check ESP after any filter upgrade.**\n**⚠️ Energy recovery**: **HRV (sensible only) vs ERV (⚠️ sensible AND latent — usually the\nright choice in humid climates).**\n**⚠️ Legionella is the serious IAQ hazard in this domain**: ⚠️ **it grows in warm stagnant\nwater — cooling towers, hot water systems held between roughly 20–45°C, and dead legs in\nplumbing.** **⚠️ Control is temperature (hot stored hot, cold kept cold), circulation, and\nelimination of stagnation; ASHRAE 188 covers water management plans.**\n\n---\n\n## §11. Heat Pumps\n\n**⚠️ A refrigeration cycle with a reversing valve — and the single most important point is\nthat COP above 1 is normal and does not violate anything** (see a thermo reference):\n**you're moving heat, not making it.**\n```\n⚠️ COP falls as the temperature LIFT rises — which is why air-source\n   performance degrades in cold weather\n⚠️ COLD-CLIMATE models use vapour injection, variable speed and better\n   controls; ⚠️ modern units maintain useful capacity well below 0°C,\n   which is a genuine change from older equipment\n⚠️ DEFROST  outdoor coil frosts below freezing; the unit periodically\n   REVERSES to melt it. ⚠️ The steam and the temporary cold air are\n   normal and are constantly misdiagnosed as faults\n⚠️ BALANCE POINT  where capacity meets load; below it, supplementary heat\n   ⚠️ RESISTANCE BACKUP has COP 1 — every hour it runs erases the savings.\n   Controls that call it unnecessarily are the main cause of\n   disappointing heat-pump bills\nGROUND-SOURCE  ⚠️ much smaller lift, higher COP, high capital cost\n```\n**⚠️ The efficiency metrics** (SEER2, HSPF2, EER, COP) ⚠️ **are seasonal averages under\ntest conditions, and real performance depends heavily on installation quality, charge\n(§5 → `hvacr-cycle-components-refrigerants-and-diagnosis`), airflow (§8) and controls.**\n\n---\n\n## §12. Controls\n\n**⚠️ Thermostats and setpoints, deadband and hysteresis (⚠️ to prevent short cycling),\nstaging, setback (⚠️ genuinely effective for furnaces and AC; ⚠️ more nuanced for heat\npumps, where a deep setback triggers resistance backup on recovery and can cost more than\nit saves).**\n**⚠️ Building automation**: **BACnet and Modbus; sequences of operation; economizer control\n(⚠️ \"free cooling\" when outdoor air is suitable — and a stuck economizer is one of the most\ncommon and most expensive commercial faults, because it fails silently).**\n**⚠️ Commissioning is the step that's skipped and shouldn't be** — ⚠️ **a correctly designed\nsystem installed and left uncommissioned routinely underperforms its specification by a\nwide margin.**\n\n---\n\n## §13. Building Envelope\n\n**⚠️ The cheapest HVAC is the load you never have.**\n**Insulation (R-value, ⚠️ and thermal bridging which defeats it locally), air sealing\n(⚠️ usually more cost-effective per pound than added insulation), windows (U-factor,\nSHGC — ⚠️ and SHGC matters more than U-factor in cooling-dominated climates), shading,\nand thermal mass.**\n**⚠️ Vapour control is climate-dependent and getting it wrong causes rot**: ⚠️ **the vapour\nretarder goes on the WARM-IN-WINTER side in heating climates, and the logic inverts in\nhot-humid climates — which is why a detail copied from the wrong climate zone traps\nmoisture inside the assembly.**\n\n---\n\n# PART III — THE COLD CHAIN\n","# Refrigeration and Climate Control: Load Calculation, Air Distribution, Humidity Control, Ventilation, Heat Pumps, Controls, and the Building Envelope\n\n> **Part 2 of 5** of the *Refrigeration, AC, Climate Control and Food\u002FWater Storage* reference (plugin `refrigeration-ac-climate-control-food-water`), covering §7–§13. Sibling skills: `hvacr-cycle-components-refrigerants-and-diagnosis` (§0–§6), `hvacr-cold-chain-temperature-limits-and-validation` (§14–§21), `hvacr-preservation-water-storage-and-treatment` (§22–§24), `hvacr-reference` (§25–§30). Section numbers are shared across the set; a reference written as §N → `skill` points into that sibling skill.\n>\n> **Currency:** The thermodynamics is permanent. Two areas moved. See §25 → `hvacr-reference` for the refrigerant transition, and cold chain capacity and food loss.\n\n> **⚠️ Everything here is one idea in different clothes: MOVING HEAT from where you don't\n> want it to where you don't care, and doing it reliably enough that the thing being\n> cooled stays safe.** **Complements a thermodynamics reference (the cycle theory and\n> psychrometrics) and a cooking\u002Fcleaning reference (food safety at the point of use).**\n>\n> **⚠️ GOTCHA** boxes mark the diagnoses people get backwards, and the safety limits that\n> aren't negotiable.\n>\n> **⚠️ Safety, stated once and up front:** ⚠️ **refrigerant systems hold high pressure and\n> can cause frostbite and asphyxiation; A2L refrigerants are mildly flammable and require\n> specific tooling and training (§25.1 → `hvacr-reference`); ammonia is toxic; and the food temperature limits\n> in §16 → `hvacr-cold-chain-temperature-limits-and-validation` are not guidance, they are the reason people don't die.** **⚠️ Refrigerant handling\n> is a certified activity in most jurisdictions — venting is illegal and recovery is\n> mandatory.**\n>\n> **The three ideas that organize this document:**\n> 1. **⚠️ SUPERHEAT and SUBCOOLING are how you see inside a sealed system** (§5 → `hvacr-cycle-components-refrigerants-and-diagnosis`).\n>    **Everything else in diagnosis is guessing.**\n> 2. **⚠️ The cold chain is only as good as its worst link, and the worst link is almost\n>    always a HANDOFF** (§15 → `hvacr-cold-chain-temperature-limits-and-validation`, §20 → `hvacr-cold-chain-temperature-limits-and-validation`). **Not the warehouse and not the truck — the dock, the\n>    delay, the unmonitored gap.**\n> 3. **⚠️ Preservation is about denying microbes ONE of their requirements** (§22 → `hvacr-preservation-water-storage-and-treatment`).\n>    **Temperature is only one option; water activity, pH, oxygen and competition are the\n>    others, and the durable methods stack several.**\n\n---\n\n## §7. Load Calculation\n\n**⚠️ Sizing by rule of thumb is the most common and most damaging HVAC error.**\n```\n⚠️ SENSIBLE LOAD  temperature — conduction through envelope, solar gain,\n   infiltration, internal gains (people, lighting, equipment)\n⚠️ LATENT LOAD    moisture — occupants, infiltration, cooking, process\n⚠️ SHR (sensible heat ratio) = sensible \u002F total. ⚠️ THE number that\n   determines whether equipment will control humidity (§9)\n⚠️ DESIGN CONDITIONS  chosen percentile, not the record extreme —\n   deliberately, because sizing for the worst hour ruins the other 8,759\n⚠️ METHOD  ACCA Manual J (residential) \u002F ASHRAE methods; ⚠️ Manual S for\n   equipment selection and Manual D for ducts\n```\n> **⚠️ GOTCHA — an OVERSIZED air conditioner performs worse, not better, and this is\n> counterintuitive to almost every homeowner.** ⚠️ **It satisfies the thermostat quickly and\n> short-cycles, which means it never runs long enough to dehumidify** (§9) — **producing a\n> cold, clammy building.** **⚠️ It also wears the compressor with frequent starts and\n> delivers worse efficiency than its rating.** **⚠️ \"Bigger to be safe\" is exactly backwards.**\n\n---\n\n## §8. Air Distribution\n\n**⚠️ Duct design**: **friction rate, equal friction and static regain methods, ⚠️ and the\nfact that flexible duct has dramatically higher resistance than smooth metal — and\ncompressed or kinked flex is a common, invisible capacity killer.**\n**⚠️ External static pressure is the vital sign of an air system** — ⚠️ **measure it; high\nESP means the blower is fighting the ductwork and airflow is below design, which shows up\nas §5 → `hvacr-cycle-components-refrigerants-and-diagnosis`'s iced evaporator.**\n**⚠️ Duct leakage in unconditioned space is a large and common loss**; **⚠️ sealing and\ninsulating ducts frequently beats equipment upgrades on cost-effectiveness.**\n**⚠️ Return path matters as much as supply**: ⚠️ **a closed bedroom door with no return path\npressurizes the room, and the air finds its way out through the envelope.**\n**Air changes per hour, throw and diffuser selection, balancing dampers, and ⚠️ VAV vs\nconstant volume.**\n\n---\n\n## §9. ⚠️ Humidity Control\n\n**⚠️ The half of comfort that equipment sizing routinely ignores.**\n```\n⚠️ Cooling coils dehumidify by condensing moisture — which requires the\n   coil surface to be BELOW the DEW POINT and requires RUN TIME\n⚠️ SHORT CYCLING = NO DEHUMIDIFICATION (§7). This is the mechanism\n⚠️ VARIABLE-SPEED equipment dehumidifies far better because it runs\n   longer at lower capacity\n⚠️ LOWER airflow across the coil = colder coil = MORE latent removal\n   and less sensible capacity — the standard trade\n⚠️ REHEAT  overcool to dehumidify, then reheat. Effective and energy-hungry\n⚠️ DEDICATED DEHUMIDIFIER or DESICCANT for high latent loads\n```\n**⚠️ Target range roughly 40–60% RH**: ⚠️ **below ~30% causes static, respiratory\ndiscomfort and wood shrinkage; above ~60% supports mould, dust mites and condensation.**\n**⚠️ Condensation control is a building-physics problem**: ⚠️ **surfaces below the dew point\nwill wet, so the failure appears at thermal bridges, uninsulated pipes and window\nframes** — **and the fix is usually insulation or ventilation, not a bigger AC.**\n**⚠️ Condensate management**: ⚠️ **blocked drains and clogged traps cause a large share of\nwater-damage callbacks; float switches are cheap insurance.**\n\n---\n\n## §10. Ventilation and Indoor Air Quality\n\n**⚠️ Ventilation dilutes; filtration removes; source control beats both.**\n**Rates per ASHRAE 62.1\u002F62.2; ⚠️ CO₂ as a PROXY for ventilation adequacy (⚠️ it's a\ntracer for occupant-generated pollutants, not itself the hazard at typical indoor\nlevels), demand-controlled ventilation.**\n**⚠️ Filtration**: **MERV and the equivalences to ISO\u002FEN ratings; ⚠️ HEPA; and ⚠️ the\ncritical caveat that fitting a high-MERV filter to a system not designed for its pressure\ndrop reduces airflow and can cause §5 → `hvacr-cycle-components-refrigerants-and-diagnosis`'s problems.** **Check ESP after any filter upgrade.**\n**⚠️ Energy recovery**: **HRV (sensible only) vs ERV (⚠️ sensible AND latent — usually the\nright choice in humid climates).**\n**⚠️ Legionella is the serious IAQ hazard in this domain**: ⚠️ **it grows in warm stagnant\nwater — cooling towers, hot water systems held between roughly 20–45°C, and dead legs in\nplumbing.** **⚠️ Control is temperature (hot stored hot, cold kept cold), circulation, and\nelimination of stagnation; ASHRAE 188 covers water management plans.**\n\n---\n\n## §11. Heat Pumps\n\n**⚠️ A refrigeration cycle with a reversing valve — and the single most important point is\nthat COP above 1 is normal and does not violate anything** (see a thermo reference):\n**you're moving heat, not making it.**\n```\n⚠️ COP falls as the temperature LIFT rises — which is why air-source\n   performance degrades in cold weather\n⚠️ COLD-CLIMATE models use vapour injection, variable speed and better\n   controls; ⚠️ modern units maintain useful capacity well below 0°C,\n   which is a genuine change from older equipment\n⚠️ DEFROST  outdoor coil frosts below freezing; the unit periodically\n   REVERSES to melt it. ⚠️ The steam and the temporary cold air are\n   normal and are constantly misdiagnosed as faults\n⚠️ BALANCE POINT  where capacity meets load; below it, supplementary heat\n   ⚠️ RESISTANCE BACKUP has COP 1 — every hour it runs erases the savings.\n   Controls that call it unnecessarily are the main cause of\n   disappointing heat-pump bills\nGROUND-SOURCE  ⚠️ much smaller lift, higher COP, high capital cost\n```\n**⚠️ The efficiency metrics** (SEER2, HSPF2, EER, COP) ⚠️ **are seasonal averages under\ntest conditions, and real performance depends heavily on installation quality, charge\n(§5 → `hvacr-cycle-components-refrigerants-and-diagnosis`), airflow (§8) and controls.**\n\n---\n\n## §12. Controls\n\n**⚠️ Thermostats and setpoints, deadband and hysteresis (⚠️ to prevent short cycling),\nstaging, setback (⚠️ genuinely effective for furnaces and AC; ⚠️ more nuanced for heat\npumps, where a deep setback triggers resistance backup on recovery and can cost more than\nit saves).**\n**⚠️ Building automation**: **BACnet and Modbus; sequences of operation; economizer control\n(⚠️ \"free cooling\" when outdoor air is suitable — and a stuck economizer is one of the most\ncommon and most expensive commercial faults, because it fails silently).**\n**⚠️ Commissioning is the step that's skipped and shouldn't be** — ⚠️ **a correctly designed\nsystem installed and left uncommissioned routinely underperforms its specification by a\nwide margin.**\n\n---\n\n## §13. Building Envelope\n\n**⚠️ The cheapest HVAC is the load you never have.**\n**Insulation (R-value, ⚠️ and thermal bridging which defeats it locally), air sealing\n(⚠️ usually more cost-effective per pound than added insulation), windows (U-factor,\nSHGC — ⚠️ and SHGC matters more than U-factor in cooling-dominated climates), shading,\nand thermal mass.**\n**⚠️ Vapour control is climate-dependent and getting it wrong causes rot**: ⚠️ **the vapour\nretarder goes on the WARM-IN-WINTER side in heating climates, and the logic inverts in\nhot-humid climates — which is why a detail copied from the wrong climate zone traps\nmoisture inside the assembly.**\n\n---\n\n# PART III — THE COLD CHAIN\n",{"name":5,"description":7},"develop","ae32736a1aabddabca5d2c96d665aa0ebc7d8700","src\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Frefrigeration-ac-climate-control-food-water\u002Fskills\u002Fhvacr-load-calculation-air-humidity-and-heat-pumps",3,"https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey","https:\u002F\u002Fthe-vibey-project.github.io\u002Fvibey\u002F","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project","https:\u002F\u002Fvibewithadam.matthewsteinberger.com","freedom for software engineers","2026-11-15 05:47:42",{"source":8,"skillName":5,"commands":35,"prompt":45,"zipAvailable":46},[36,39,42],{"tool":37,"command":38},"npx","npx skills add the-vibey-project\u002Fvibey --skill hvacr-load-calculation-air-humidity-and-heat-pumps",{"tool":40,"command":41},"bunx","bunx skills add the-vibey-project\u002Fvibey --skill hvacr-load-calculation-air-humidity-and-heat-pumps",{"tool":43,"command":44},"pnpm","pnpm dlx skills add the-vibey-project\u002Fvibey --skill hvacr-load-calculation-air-humidity-and-heat-pumps","安装技能，技能地址：https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Frefrigeration-ac-climate-control-food-water\u002Fskills\u002Fhvacr-load-calculation-air-humidity-and-heat-pumps\u002FSKILL.md",true,[],[49,56,63,70,77,84],{"skillNo":50,"name":51,"nameZh":6,"description":52,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":53,"categories":54,"keywords":55,"publishedAt":19},"01M7AT1FQJAE1FQYAMDTF490Y4","white-paper-writing","Use when writing white papers, technical reports, policy documents, thought leadership pieces, or any long-form authoritative document. Triggers on requests to write, structure, outline, or review white papers, technical reports, position papers, policy briefs, or evidence-driven arguments. Also use for B2B content marketing strategy, technical documentation requiring authority, academic-style reports, or any document that must educate while persuading. Use when someone asks \"how should I structure this\" for a long-form document.","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Fwriting-craft\u002Fskills\u002Fwhite-paper-writing\u002FSKILL.md",[],[],{"skillNo":57,"name":58,"nameZh":6,"description":59,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":60,"categories":61,"keywords":62,"publishedAt":19},"01M7AT16BJRJJKK2MASXRZS76G","prose-technical-mechanics","Use when editing or writing prose at a technical\u002Fmechanical level: choosing between Anglo-Saxon and Latinate diction, placing information in topic vs stress positions, writing periodic vs cumulative sentences, handling sentence rhythm, punctuation as logic, transitions, paragraph structure, or phonesthetics. Use when someone wants to understand WHY prose works or doesn't, not just surface-level style advice. Triggers on word choice, sentence structure, emphasis, rhythm, diction, or any deep writing mechanics question.","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Fwriting-craft\u002Fskills\u002Fprose-technical-mechanics\u002FSKILL.md",[],[],{"skillNo":64,"name":65,"nameZh":6,"description":66,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":67,"categories":68,"keywords":69,"publishedAt":19},"01M7AT0W9HT0ZZ9Y287NW99MR3","prose-mechanics","Use when writing, editing, or analyzing prose style; when trying to avoid generic AI-sounding writing; when applying specific prose styles such as journalistic, academic, narrative, KJV biblical, Hemingway plain, Latinate\u002FJamesian, Orwellian, Augustan, Victorian, Early Modern (Bacon, Browne, Milton), or free indirect discourse; or when coaching someone on writing voice and mechanics. Triggers on any request to improve, analyze, or write in a specific prose style, to fix \"AI-sounding\" writing, to make prose more vivid or concrete, to vary sentence rhythm, or to understand how a particular writer achieves their effects.","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Fwriting-craft\u002Fskills\u002Fprose-mechanics\u002FSKILL.md",[],[],{"skillNo":71,"name":72,"nameZh":6,"description":73,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":74,"categories":75,"keywords":76,"publishedAt":19},"01M7AT0KR635JX66X2X6F3E2CP","narrative-structure","Use when structuring stories, pitches, presentations, white papers, or any persuasive narrative; analyzing the hero's journey in fiction or non-fiction; applying StoryBrand for business communication; designing narrative arcs for thought leadership; or understanding Vogler, Snyder, Propp, or Campbell frameworks. Triggers on any narrative structure, storytelling, pitch structure, StoryBrand, hero's journey, three-act structure, Freytag, Save the Cat, narrative arc, or \"how should I structure this story\u002Fpitch\u002Fpresentation\" request.","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Fwriting-craft\u002Fskills\u002Fnarrative-structure\u002FSKILL.md",[],[],{"skillNo":78,"name":79,"nameZh":6,"description":80,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":81,"categories":82,"keywords":83,"publishedAt":19},"01M7AT0AKGW09NKKZDYBT8VRDE","legal-brief-writing","Use when writing legal briefs, motions, or any court filing; when analyzing judicial cognition and persuasion; when applying elite brief-writing techniques from Roberts, Clement, Kagan, Garner; or when structuring legal arguments for maximum persuasion. Also use for autistic\u002Fneurodivergent advocates who need to understand how their natural communication style maps to elite legal advocacy. Triggers on any legal writing, brief drafting, motion preparation, or legal argument structuring request.","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Fwriting-craft\u002Fskills\u002Flegal-brief-writing\u002FSKILL.md",[],[],{"skillNo":85,"name":86,"nameZh":6,"description":87,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":88,"categories":89,"keywords":90,"publishedAt":19},"01M7AT00VWPS4Q8B5VEMXX9NQT","journal-publishability-criteria","Use whenever a research paper, article or preprint is being written, revised, reviewed or published, and specifically before every publication of docs\u002Fpaper.md. Covers what legitimate journals actually gate on, in order of gating — the editor's desk screen (scope, novelty, package problems), what reviewers judge (methodological soundness, claims the evidence can carry, statistical and qualitative reporting), EQUATOR reporting guidelines, the ICMJE authorship criteria, COPE's view of text recycling, the near-universal generative-AI policy (no AI author, disclosure, author responsibility), TOP 2025 transparency standards, how to verify a journal is legitimate, submitting without an institution, and a pre-submission checklist. Triggers on requests to evaluate, review, prepare or submit a paper, to judge publishability, to write a declarations or data-availability section, to disclose AI use, or to check a journal.","https:\u002F\u002Fgithub.com\u002Fthe-vibey-project\u002Fvibey\u002Fblob\u002Fdevelop\u002Fsrc\u002Fvibey_tools\u002Fskills\u002Fplugins\u002Fwriting-craft\u002Fskills\u002Fjournal-publishability-criteria\u002FSKILL.md",[],[]]