achieving-cmmc-level-2-compliance
Prepare a defense-contractor environment for CMMC Level 2 certification: scope CUI and FCI, implement the 110 NIST SP 800-171 Rev 2 security requirements across 14 families, compute the SPRS score with the DoD Assessment Methodology, manage a compliant POA&M, and ready the organization for a C3PAO assessment. Use when an organization handles Controlled Unclassified Information (CUI) under a DoD contract, when a contract carries DFARS clause 252.204-7012/7019/7020/7021, when preparing for or responding to a CMMC assessment, when computing or improving an SPRS score, when building a System Security Plan or POA&M for 800-171, or when scoping which systems are in the CUI boundary. Keywords: CMMC, CMMC Level 2, NIST 800-171, SP 800-171 Rev 2, CUI, FCI, SPRS, DFARS 7012, C3PAO, POA&M, System Security Plan, DoD Assessment Methodology, 110 controls, defense industrial base, DIB, FedRAMP equivalency.
- License 许可
- Apache-2.0
- 最近更新
- 2026-09-11
- Stars
- ★ 0
- Forks
- 0
01 前言 Front Matter
- name
- achieving-cmmc-level-2-compliance
- tags
- [ "cmmc", "nist-800-171", "cui", "sprs", "dfars", "c3pao", "poam", "compliance", "governance", "defense-industrial-base" ]
- author
- andrewibrah
- domain
- cybersecurity
- license
- Apache-2.0
- version
- 1.0
- nist_csf
- [ "GV.OC-03", "GV.SC-01", "ID.AM-08", "ID.RA-05", "PR.AA-01", "PR.DS-01" ]
- subdomain
- compliance-governance
- description
- Prepare a defense-contractor environment for CMMC Level 2 certification: scope CUI and FCI, implement the 110 NIST SP 800-171 Rev 2 security requirements across 14 families, compute the SPRS score with the DoD Assessment Methodology, manage a compliant POA&M, and ready the organization for a C3PAO assessment. Use when an organization handles Controlled Unclassified Information (CUI) under a DoD contract, when a contract carries DFARS clause 252.204-7012/7019/7020/7021, when preparing for or responding to a CMMC assessment, when computing or improving an SPRS score, when building a System Security Plan or POA&M for 800-171, or when scoping which systems are in the CUI boundary. Keywords: CMMC, CMMC Level 2, NIST 800-171, SP 800-171 Rev 2, CUI, FCI, SPRS, DFARS 7012, C3PAO, POA&M, System Security Plan, DoD Assessment Methodology, 110 controls, defense industrial base, DIB, FedRAMP equivalency.
- mitre_attack
- [ "T1078", "T1190", "T1041", "T1048", "T1567" ]
02 资源文件 4
- 资产文件assets/template.md3.7 KB
- 许可证LICENSE11.0 KB
- 参考文档references/standards.md4.8 KB
- 脚本scripts/process.py7.6 KB
03 SKILL.md 正文
Achieving CMMC Level 2 Compliance
When to Use
- When an organization in the Defense Industrial Base (DIB) stores, processes, or transmits Controlled Unclassified Information (CUI) under a DoD contract.
- When a contract includes DFARS 252.204-7012 (safeguarding/incident reporting), -7019/-7020 (NIST 800-171 self-assessment + SPRS), or the new -7021 (CMMC requirement).
- When preparing for a C3PAO third-party assessment or a DoD-led assessment.
- When you must compute, post, or improve an SPRS score based on the NIST SP 800-171 DoD Assessment Methodology.
- When authoring or remediating a System Security Plan (SSP) and POA&M for the 110 requirements.
- When scoping which assets fall inside the CUI/FCI boundary (CUI assets, security-protection assets, contractor risk-managed assets, out-of-scope).
Prerequisites
- Knowledge of which contracts carry CUI and the CUI categories involved (check the contract and the DoD CUI Registry).
- An asset inventory and network diagram so you can define the CMMC assessment scope before assessing controls.
- The NIST SP 800-171 Rev 2 requirements and the DoD Assessment Methodology scoring weights.
- A documented SSP (its absence is itself a failed requirement — 3.12.4).
- Identification of any External Service Providers (ESPs) / cloud services touching CUI, and whether they meet FedRAMP Moderate (or equivalency).
Workflow
1. Determine applicability and CUI categories
Confirm the contract requires CMMC Level 2 (CUI present, not just FCI). FCI-only contracts are Level 1 (the 15 FAR 52.204-21 requirements). Identify CUI categories from the contract and the DoD CUI Registry.
2. Scope the environment
Classify every asset into one of the CMMC scoping categories:
- CUI Assets — process/store/transmit CUI (in scope, assessed against all applicable controls).
- Security Protection Assets — provide security to the CUI environment (in scope).
- Contractor Risk Managed Assets — could but are not intended to handle CUI; managed by policy.
- Specialized Assets (IoT/OT, GFE, test equipment) — documented, limited assessment.
- Out-of-Scope — physically/logically isolated from CUI.
Minimize scope deliberately — a smaller, well-segmented CUI enclave is far cheaper to certify than a flat network.
3. Implement the 110 requirements (NIST SP 800-171 Rev 2)
Work the 14 families (3.1–3.14). For each requirement, implement, then write the how in the SSP. High-leverage early wins: MFA (3.5.3), FIPS-validated cryptography (3.13.11), audit logging (3.3.x), access control + least privilege (3.1.x), and incident response (3.6.x).
4. Score with the DoD Assessment Methodology (SPRS)
Start at 110 and subtract the weighted value (1, 3, or 5 points) of each unmet requirement; partial credit applies to a small number of controls (e.g., MFA, FIPS crypto). The result is the SPRS score (maximum 110; the methodology floor is −203). Post the score, the SSP date, and the assessment scope to SPRS (or eMASS for higher assessments).
5. Build a compliant POA&M
Document every unmet requirement with owner, remediation, and milestone. Constraints under the CMMC rule: a Conditional status requires a score of at least 80% (≥ 88 of 110), only POA&M-eligible requirements may be deferred (the highest-weighted security requirements must be fully met — verify eligibility against 32 CFR Part 170), and all POA&M items must be closed within 180 days to convert Conditional → Final.
6. Assess (self or C3PAO)
- Level 1 and a subset of Level 2 = annual self-assessment with an affirmation in SPRS.
- Level 2 (most CUI contracts) = triennial C3PAO certification assessment.
- Level 3 = DoD (DIBCAC) assessment on top of Level 2, adding SP 800-172 enhanced requirements. Assessors evaluate each objective as MET / NOT MET / N/A with evidence (examine/interview/test). A senior official files the annual affirmation of continued compliance.
7. Maintain certification
Certification is valid three years with annual affirmations. Maintain the SSP, re-score on change, keep evidence current, and feed significant changes back into the assessment.
Key Concepts
| Concept | Definition |
|---|---|
| FCI | Federal Contract Information — Level 1 protects it (FAR 52.204-21). |
| CUI | Controlled Unclassified Information — Level 2 protects it (NIST 800-171). |
| 110 requirements | The SP 800-171 Rev 2 security requirements across 14 families. |
| SPRS | Supplier Performance Risk System — where the 800-171 score is posted. |
| DoD Assessment Methodology | The 1/3/5-point weighting used to compute the score from 110. |
| C3PAO | CMMC Third-Party Assessment Organization — performs Level 2 certification. |
| POA&M | Plan of Action & Milestones — limited, must close in 180 days for Final status. |
| Conditional vs Final | Conditional = open POA&M (score ≥ 80%); Final = all controls met. |
| ESP | External Service Provider — must meet FedRAMP Moderate / equivalency for CUI. |
| Scoping categories | CUI / Security Protection / Contractor Risk Managed / Specialized / Out-of-Scope. |
Tools & Systems
- NIST SP 800-171 Rev 2 — the 110 requirements (and 800-171A for assessment objectives).
- DoD NIST SP 800-171 Assessment Methodology — the scoring weights.
- 32 CFR Part 170 (CMMC Program rule) and 48 CFR / DFARS 252.204-7021 (acquisition rule).
- SPRS — score posting; SAM.gov for registration.
- SP 800-172 / 800-172A — enhanced requirements for Level 3.
- GRC / compliance tooling — to manage the SSP, POA&M, and evidence (e.g., Xacta, RegScale, FutureFeed-style trackers).
Common Scenarios
- Prime flows CUI to a sub. The sub needs its own Level 2 scope, SSP, SPRS score, and (most likely) C3PAO certification.
- Score is below 88. Prioritize the highest-weighted unmet requirements (5-point, then 3-point) to clear the conditional threshold and shrink the POA&M.
- Cloud holds CUI. Confirm the service is FedRAMP Moderate authorized or meets equivalency; document the responsibility split.
- Flat network. Re-scope into a segmented CUI enclave to cut the assessment surface before spending on controls.
- Annual affirmation due. A senior official affirms continued compliance in SPRS; let it lapse and you risk contract eligibility.
Output Format
Produce a CMMC Level 2 Readiness Report using assets/template.md, containing:
- Applicability & CUI categories — why Level 2 applies.
- Scope — assets by scoping category and the CUI boundary diagram reference.
- Control status by family — met / not met / N/A across the 14 families.
- SPRS score — computed score, deductions, and the gap to 110 and to the 88 threshold.
- POA&M — unmet requirements, eligibility check, owners, 180-day milestones.
- Assessment path — self vs C3PAO, target date, affirmation owner.
- Remediation roadmap — sequenced by point value and effort.
Use scripts/process.py to compute the SPRS score from a control-status JSON, flag POA&M-eligibility concerns, and report the gap to the conditional-certification threshold.
04 同仓库更多 Skills
runpodctl
Runpod CLI for managing GPU/CPU workloads from the terminal — pods, serverless endpoints, templates, network volumes, Hub deploys, models, SSH, and file transfer (send/receive). Use for terminal/CI/scripting, Hub browse/deploy, SSH setup, `doctor`, or when the Runpod MCP tools are not connected. For structured tool calls in an MCP-enabled session, prefer runpod-mcp.
runpod
Start here for any Runpod task — running GPU/CPU pods, deploying serverless endpoints, templates, network volumes, building images, or understanding how Runpod works. Routes to the right skill (runpod-mcp, runpodctl, flash, companion-clis, runpod-usage, runpod-templates, runpod-migrate) and indexes two dozen live-verified end-to-end examples (golden paths) — use it when the lane is unclear, and for any multi-step or provisioning task even when it is not.
runpod-usage
How Runpod works and how to work it — pods vs serverless, GPU/VRAM selection, storage, building a container, networking, plus the agentic pod development loop (provision → ssh-exec → set up → poll readiness) and on-pod install hygiene (uv/apt). Use to answer "how does X work", "which GPU", "how do I build a container", or "how do I stand up a workload on a pod". Guidance, not a tool — execute with runpodctl, runpod-mcp, or flash.
runpod-templates
Runpod's official prebuilt pod templates (ComfyUI, PyTorch, and others): what each image ships, which ports and paths it uses, how to pick one, how to pin a version, and what is missing on first boot. Use when a task says "run <X> on a pod" and an official template already covers it, instead of building an image — and when a user needs help with or wants to fix something about a Runpod template they are already running (won't boot, can't reach the UI, missing models, wrong CUDA line, broken ComfyUI workflow metadata on imported workflows): start here and route onward. Deploy with runpodctl or runpod-mcp; end-to-end walkthroughs live in the runpod router's golden paths.
runpod-migrate
Migrate a codebase from the Runpod GraphQL API or REST v1 to REST v2 — inventory which parts use which API version, rewrite the call sites, flag breaking changes, and verify. Use when someone asks to move to v2, asks what v2 would change, or asks which Runpod API their code is on. For managing infrastructure rather than migrating code, use runpod-mcp or runpodctl.
runpod-mcp
Manage Runpod infrastructure — pods, serverless endpoints, jobs, templates, network volumes, container-registry auth, GPU/CPU catalog, and billing — via the Runpod MCP server's structured tool calls. Use when the Runpod MCP tools (create-pod, list-endpoints, …) are connected in this session, or to connect them (hosted OAuth or local npx). Prefer this over runpodctl for plain infra CRUD when MCP is available; use runpodctl for the terminal, file transfer, or SSH setup.