arc-flash-analyzer
Arc flash hazard analysis per IEEE 1584. Computes incident energy, arc flash boundary, PPE category for high voltage work.
- License 许可
- AGPL-3.0
- 最近更新
- 2026-11-14
- Stars
- ★ 25
- Forks
- 9
01 前言 Front Matter
- lang
- ko
- name
- arc-flash-analyzer
- owner
- powergen-agent
- scope
- co-safety
- mirror
- false
- status
- active
- created
- 2026-06-18
- version
- 1.0.0
- metadata
- { "type": "domain", "triggers": [ "아크 플래시", "arc flash", "IEEE 1584", "고압 전기 작업", "PPE category", "incident energy", "NFPA 70E", "활선 작업 허가" ], "legal_basis": [ "전기안전관리법 제12조", "전기사업법 제67조", "산업안전보건법 제38조", "발전설비 안전관리 규정(산업통상자원부 고시)" ] }
- description
- Arc flash hazard analysis per IEEE 1584. Computes incident energy, arc flash boundary, PPE category for high voltage work.
- lang_reason
- legal
- last_updated
- 2026-08-26
03 SKILL.md 正文
audit_exception: safety-os-skill-structure — Safety OS skills use the legal_basis-gated SSOT skill format (validated by scripts/skill-lifecycle-audit.ts and scripts/validate-skills.ts), not the generic template 5-section/7-frontmatter schema
Arc Flash Analyzer Skill
Overview
IEEE 1584 standard 기반 아크 플래시 위해 분석 — incident energy, arc flash boundary, PPE category 계산하여 고압 전기 작업 안전 확보.
Key Concepts
Incident Energy (침입 에너지)
- 작업자 위치에서 아크 폭발 시 받을 열에너지
- 단위: cal/cm²
- 임계값: 1.2 cal/cm² (2도 화상 임계)
Arc Flash Boundary
- 침입 에너지가 1.2 cal/cm² 도달 거리
- 이 경계 내 작업 시 PPE 필수
PPE Category (NFPA 70E)
- Category 1: 4 cal/cm² (최소 ARC rated PPE)
- Category 2: 8 cal/cm² (ARC rated clothing + face shield)
- Category 3: 25 cal/cm² (ARC flash suit)
- Category 4: 40 cal/cm² (heavy ARC flash suit)
-
Category 4: 작업 금지 (전원 차단 후 작업)
IEEE 1584 Inputs
Required Parameters
- System voltage (kV)
- Bolted fault current (kA)
- Arcing current (calculated from bolted)
- Arc gap (mm)
- Working distance (cm)
- Equipment type (open air / switchgear / panelboard / cable)
- Grounding type (grounded / ungrounded)
- Arc duration (seconds) — typically clearing time of protective device
Calculation Output
- Incident energy (cal/cm²)
- Arc flash boundary (m)
- PPE category required
Workflow Steps
-
System Data Collection
- Single-line diagram review
- Short circuit study (bolting fault)
- Protective device coordination study
-
Calculation
- Apply IEEE 1584 empirical equations
- Use IEEE 1584-2018 updated model (vs older 2002)
- Consider equipment configuration factors
-
Label Generation
- Arc flash warning labels per NFPA 70E
- Post on all electrical equipment
-
PPE Selection
- Match PPE category to incident energy
- Specify exact equipment (face shield, gloves, etc.)
-
Work Permit
- Energized work permit if live work required
- Justification for not de-energizing
Korean-Specific
- 한국전기안전공사 (KESCO) 아크 플래시 가이드
- 한국산업안전보건공단 (KOSHA) 고압 전기 작업 가이드
- 산업안전보건법 Article 38 (전기 위해 방지 포함 안전조치)
- 발전설비 안전관리 규정 (MOTIE 고시)
Output
{
"analysis_id": "...",
"equipment_id": "GEN-SW-345-001",
"voltage_kv": 345,
"bolted_fault_current_ka": 40,
"arcing_current_ka": 28,
"working_distance_cm": 45,
"arc_duration_s": 0.2,
"incident_energy_cal_cm2": 18.5,
"arc_flash_boundary_m": 1.8,
"ppe_category": 3,
"required_ppe": ["ARC flash suit (25+ cal/cm²)", "ARC rated hood", "insulated gloves class 2"],
"label_generated": true,
"live_work_recommended": false
}
Integration
- Input from: Single-line diagrams, short circuit study results
- Output to:
powergen-high-voltage-record.jsonarc flash fields - External: ETAP, SKM, EasyPower (v2 roadmap)
v2 Roadmap
- 5-cycle analysis for breakers
- Dynamic arc resistance model
- Real-time PPE verification
Legal Disclaimer
IEEE 1584 준거 자동 분석. 최종 안전 작업 판정은 자격을 갖춘 전기안전관리자 + 작업 책임자.
04 同仓库更多 Skills
i18n-layout
Text layout and encoding guidance: character encoding (UTF-8, legacy Korean code pages, BOM hazards), line endings, RTL/bidi handling, and script-specific font selection (Hangul focus). Use when: encoding is corrupted or mojibake appears, an RTL locale must render correctly, fonts must be chosen for a script, or CRLF/BOM issues surface.
i18n-layout
Text layout and encoding guidance: character encoding (UTF-8, legacy Korean code pages, BOM hazards), line endings, RTL/bidi handling, and script-specific font selection (Hangul focus). Use when: encoding is corrupted or mojibake appears, an RTL locale must render correctly, fonts must be chosen for a script, or CRLF/BOM issues surface.
i18n-layout
Text layout and encoding guidance: character encoding (UTF-8, legacy Korean code pages, BOM hazards), line endings, RTL/bidi handling, and script-specific font selection (Hangul focus). Use when: encoding is corrupted or mojibake appears, an RTL locale must render correctly, fonts must be chosen for a script, or CRLF/BOM issues surface.
i18n-layout
Text layout and encoding guidance: character encoding (UTF-8, legacy Korean code pages, BOM hazards), line endings, RTL/bidi handling, and script-specific font selection (Hangul focus). Use when: encoding is corrupted or mojibake appears, an RTL locale must render correctly, fonts must be chosen for a script, or CRLF/BOM issues surface.
i18n-layout
Text layout and encoding guidance: character encoding (UTF-8, legacy Korean code pages, BOM hazards), line endings, RTL/bidi handling, and script-specific font selection (Hangul focus). Use when: encoding is corrupted or mojibake appears, an RTL locale must render correctly, fonts must be chosen for a script, or CRLF/BOM issues surface.
i18n-layout
Text layout and encoding guidance: character encoding (UTF-8, legacy Korean code pages, BOM hazards), line endings, RTL/bidi handling, and script-specific font selection (Hangul focus). Use when: encoding is corrupted or mojibake appears, an RTL locale must render correctly, fonts must be chosen for a script, or CRLF/BOM issues surface.