[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"skill:01M73CS0DNTX27DNWD48BKFBTT":3,"skill-same:01M73CS0DNTX27DNWD48BKFBTT":92},{"skillNo":4,"name":5,"nameZh":6,"description":7,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":16,"sourceHtmlUrl":17,"categories":18,"keywords":19,"publishedAt":20,"linkOnly":21,"markdownContent":22,"markdownBody":23,"frontMatter":24,"refName":52,"commitSha":53,"skillDirectory":54,"forksCount":55,"repositoryHtmlUrl":56,"repositoryHomepageUrl":57,"ownerHtmlUrl":58,"ownerBlogUrl":59,"ownerDescription":60,"updatedAt":61,"install":62,"resources":75},"01M73CS0DNTX27DNWD48BKFBTT","implementing-iec-62443-security-zones",null,"This skill covers designing and implementing security zones and conduits for industrial automation and control systems (IACS) per IEC 62443-3-2. It addresses zone partitioning based on risk assessment, assigning Security Level targets (SL-T), designing conduit security controls, implementing microsegmentation with industrial firewalls, and validating zone architecture through traffic analysis and penetration testing against the Purdue Reference Model.","Horonomos-laps\u002FYana-AI","Horonomos-laps","https:\u002F\u002Favatars.githubusercontent.com\u002Fu\u002F355299122?v=4","01M76B3QPXE88ET2SQPDPVATZT"," Horonomos-laps","01M72ZQRJPCYPSSWT4D00VJR2A",13,"Apache-2.0","https:\u002F\u002Fgithub.com\u002Fyanacuti1121\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002FLICENSE","https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002FSKILL.md",[],[],"2026-11-11 15:11:14",false,"---\nname: implementing-iec-62443-security-zones\ndescription: 'This skill covers designing and implementing security zones and conduits\n  for industrial automation and control systems (IACS) per IEC 62443-3-2. It addresses\n  zone partitioning based on risk assessment, assigning Security Level targets (SL-T),\n  designing conduit security controls, implementing microsegmentation with industrial\n  firewalls, and validating zone architecture through traffic analysis and penetration\n  testing against the Purdue Reference Model.\n\n  '\ndomain: cybersecurity\nsubdomain: ot-ics-security\ntags:\n- ot-security\n- ics\n- scada\n- industrial-control\n- iec62443\n- network-segmentation\n- zones-conduits\nversion: 1.0.0\nauthor: mahipal\nlicense: Apache-2.0\nnist_csf:\n- PR.IR-01\n- DE.CM-01\n- ID.AM-05\n- GV.OC-02\nmitre_attack:\n- T1078\n- T1190\n- T1059\n- T0816\n- T0836\nsource: https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\nsource_commit: 04450304b12645cb2b974ab96d28c0664758a88d\nnote: \"Vendored verbatim from an external Apache-2.0 security-skill library, pinned by commit. Exceeds the internal 300-line skill guideline (agent-code-constraints.md) -- kept as-is because this is vendored reference material (forensics\u002Fthreat-intel procedure), not Yana AI-authored content, and trimming would damage technical accuracy.\"\n---\n\n# Implementing IEC 62443 Security Zones\n\n## When to Use\n\n- When designing a greenfield OT network architecture for a new industrial facility\n- When retrofitting security zones into an existing flat OT network after an assessment finding\n- When implementing network segmentation to comply with IEC 62443-3-2 certification requirements\n- When upgrading from basic VLAN segmentation to policy-enforced zone\u002Fconduit architecture\n- When an IT\u002FOT convergence project requires defining security boundaries between enterprise and operational networks\n\n**Do not use** for IT-only network segmentation (see implementing-network-microsegmentation), for cloud-native workload segmentation (see securing-kubernetes-on-cloud), or for physical security zone design without a cyber component.\n\n## Prerequisites\n\n- Completed OT network security assessment with asset inventory and traffic flow analysis\n- Understanding of IEC 62443-3-2 zone\u002Fconduit design process and the Purdue Reference Model\n- Industrial firewalls capable of deep packet inspection for OT protocols (Palo Alto with OT Security, Fortinet OT, Cisco ISA-3000)\n- Network switches supporting VLANs, 802.1Q trunking, and port security\n- Approval from operations management for network architecture changes during maintenance windows\n\n## Workflow\n\n### Step 1: Perform Zone Partitioning Based on Risk Assessment\n\nPartition the IACS into zones based on functional requirements, security requirements, criticality, and consequence of compromise. Each zone contains assets with common security requirements.\n\n```yaml\n# IEC 62443-3-2 Zone Definition Document\nfacility: \"Petrochemical Refinery - Unit 3\"\nassessment_date: \"2026-02-23\"\nstandard: \"IEC 62443-3-2:2020\"\n\nzones:\n  - zone_id: \"Z1-SIS\"\n    name: \"Safety Instrumented Systems\"\n    purdue_level: 1\n    security_level_target: \"SL 3\"\n    criticality: \"Safety Critical\"\n    assets:\n      - \"Triconex 3008 Safety Controller (SIS-01)\"\n      - \"Triconex 3008 Safety Controller (SIS-02)\"\n      - \"SIS Engineering Workstation\"\n    security_requirements:\n      - \"Physically isolated from all other zones (air-gapped)\"\n      - \"Dedicated engineering workstation with removable media controls\"\n      - \"No remote access permitted under any circumstances\"\n      - \"Change management requires dual authorization\"\n    allowed_conduits: []  # No network conduits - fully air-gapped\n\n  - zone_id: \"Z2-BPCS\"\n    name: \"Basic Process Control System\"\n    purdue_level: \"1-2\"\n    security_level_target: \"SL 2\"\n    criticality: \"High\"\n    assets:\n      - \"Allen-Bradley ControlLogix PLCs (PLC-01 through PLC-12)\"\n      - \"Rockwell FactoryTalk View HMIs (HMI-01 through HMI-06)\"\n      - \"Engineering Workstation (EWS-01)\"\n    security_requirements:\n      - \"Industrial firewall at zone boundary with protocol inspection\"\n      - \"Read-only access from Level 3 for data acquisition\"\n      - \"Write access restricted to engineering workstation subnet\"\n      - \"USB ports disabled on HMIs\"\n    allowed_conduits: [\"C1-BPCS-OPS\"]\n\n  - zone_id: \"Z3-OPS\"\n    name: \"Site Operations\"\n    purdue_level: 3\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"OSIsoft PI Historian (HIST-01)\"\n      - \"OPC UA Server (OPC-01)\"\n      - \"MES Application Server (MES-01)\"\n      - \"Alarm Management Server (ALM-01)\"\n    security_requirements:\n      - \"Firewall between operations and control zones\"\n      - \"Firewall between operations and DMZ\"\n      - \"No direct internet access\"\n      - \"Antivirus with OT-approved signatures\"\n    allowed_conduits: [\"C1-BPCS-OPS\", \"C2-OPS-DMZ\"]\n\n  - zone_id: \"Z4-DMZ\"\n    name: \"Industrial Demilitarized Zone\"\n    purdue_level: 3.5\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"PI-to-PI Interface (DMZ-HIST-01)\"\n      - \"Patch Management Server (DMZ-WSUS-01)\"\n      - \"Remote Access Jump Server (DMZ-JUMP-01)\"\n      - \"Data Diode - Waterfall Security (DMZ-DD-01)\"\n    security_requirements:\n      - \"Dual-homed firewalls on both sides\"\n      - \"No direct traffic traversal - all connections terminate in DMZ\"\n      - \"Data diode for unidirectional historian replication\"\n      - \"Jump server with MFA for remote access\"\n    allowed_conduits: [\"C2-OPS-DMZ\", \"C3-DMZ-ENT\"]\n\n  - zone_id: \"Z5-ENT\"\n    name: \"Enterprise Network\"\n    purdue_level: 4\n    security_level_target: \"SL 1\"\n    criticality: \"Low (from OT perspective)\"\n    assets:\n      - \"Corporate systems accessing OT data\"\n    security_requirements:\n      - \"Firewall between enterprise and DMZ\"\n      - \"No direct access to any OT zone below DMZ\"\n    allowed_conduits: [\"C3-DMZ-ENT\"]\n\nconduits:\n  - conduit_id: \"C1-BPCS-OPS\"\n    name: \"Control-to-Operations Conduit\"\n    connects: [\"Z2-BPCS\", \"Z3-OPS\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"OPC UA\"\n        port: 4840\n        direction: \"Z2 -> Z3 (read only)\"\n        security_mode: \"SignAndEncrypt\"\n      - protocol: \"Modbus\u002FTCP\"\n        port: 502\n        direction: \"Z3 -> Z2 (read only, FC 3\u002F4 only)\"\n        security_mode: \"Firewall-enforced function code filtering\"\n    controls:\n      - \"Industrial firewall with OT protocol DPI\"\n      - \"Allowlisted source\u002Fdestination IP pairs\"\n      - \"Function code filtering (block all write operations from L3)\"\n      - \"Connection rate limiting\"\n\n  - conduit_id: \"C2-OPS-DMZ\"\n    name: \"Operations-to-DMZ Conduit\"\n    connects: [\"Z3-OPS\", \"Z4-DMZ\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"PI-to-PI\"\n        port: 5450\n        direction: \"Z3 -> Z4 (unidirectional via data diode)\"\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z4 -> Z3 (patch downloads only)\"\n    controls:\n      - \"Data diode for historian replication (Waterfall Security)\"\n      - \"Firewall with application-layer inspection\"\n      - \"Patch server pulls only from approved vendor repositories\"\n\n  - conduit_id: \"C3-DMZ-ENT\"\n    name: \"DMZ-to-Enterprise Conduit\"\n    connects: [\"Z4-DMZ\", \"Z5-ENT\"]\n    security_level: \"SL 1\"\n    protocols_allowed:\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z5 -> Z4 (historian read, remote access portal)\"\n      - protocol: \"RDP\"\n        port: 3389\n        direction: \"Z5 -> Z4 (jump server with MFA)\"\n    controls:\n      - \"Next-gen firewall with SSL inspection\"\n      - \"MFA required for all remote access sessions\"\n      - \"Session recording on jump server\"\n```\n\n### Step 2: Configure Industrial Firewalls for Zone Boundaries\n\nDeploy and configure industrial-grade firewalls at each zone boundary with OT protocol-aware deep packet inspection.\n\n```bash\n# Cisco ISA-3000 Industrial Firewall Configuration\n# Conduit C1: BPCS (Zone 2) \u003C-> Operations (Zone 3)\n\n# Define zone interfaces\ninterface GigabitEthernet1\u002F1\n  nameif zone-bpcs\n  security-level 90\n  ip address 10.20.1.1 255.255.0.0\n\ninterface GigabitEthernet1\u002F2\n  nameif zone-ops\n  security-level 70\n  ip address 10.30.1.1 255.255.0.0\n\n# OPC UA from BPCS to Operations (read-only data flow)\naccess-list BPCS-to-OPS extended permit tcp 10.20.0.0 255.255.0.0 host 10.30.1.50 eq 4840\n# Modbus read from Operations historian to PLCs (FC 3,4 only)\naccess-list OPS-to-BPCS extended permit tcp host 10.30.1.50 10.20.0.0 255.255.0.0 eq 502\n\n# Deny all other traffic between zones\naccess-list BPCS-to-OPS extended deny ip any any log\naccess-list OPS-to-BPCS extended deny ip any any log\n\n# Apply access lists\naccess-group BPCS-to-OPS in interface zone-bpcs\naccess-group OPS-to-BPCS in interface zone-ops\n\n# Enable Modbus protocol inspection with function code filtering\npolicy-map type inspect modbus MODBUS-INSPECT\n  parameters\n    # Allow read operations only from Operations zone\n    match func-code read-coils\n    match func-code read-discrete-inputs\n    match func-code read-holding-registers\n    match func-code read-input-registers\n    # Block all write function codes\n    match func-code force-single-coil  action drop log\n    match func-code preset-single-register  action drop log\n    match func-code force-multiple-coils  action drop log\n    match func-code preset-multiple-registers  action drop log\n\n# Apply to service policy\npolicy-map global_policy\n  class inspection_default\n    inspect modbus MODBUS-INSPECT\n\n# Logging to OT SIEM\nlogging host zone-ops 10.30.1.60\nlogging trap informational\nlogging enable\n```\n\n### Step 3: Implement VLAN Segmentation at Switch Level\n\nConfigure network switches to enforce zone boundaries at Layer 2, preventing broadcast domain overlap between Purdue levels.\n\n```bash\n# Cisco Industrial Ethernet Switch Configuration\n# Zone-based VLAN assignment\n\n# VLAN definitions aligned with zones\nvlan 10\n  name Z1-SIS-Safety\nvlan 20\n  name Z2-BPCS-Control\nvlan 30\n  name Z3-OPS-Operations\nvlan 35\n  name Z4-DMZ\nvlan 40\n  name Z5-Enterprise\n\n# PLC ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F1-12\n  description PLC connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation shutdown\n  spanning-tree portfast\n  spanning-tree bpduguard enable\n  no cdp enable\n  no lldp transmit\n\n# HMI ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F13-18\n  description HMI connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation restrict\n  spanning-tree portfast\n\n# Trunk to industrial firewall\ninterface GigabitEthernet1\u002F0\u002F24\n  description Trunk to ISA-3000 Firewall\n  switchport mode trunk\n  switchport trunk allowed vlan 20,30,35\n  switchport trunk native vlan 999\n\n# Disable unused ports\ninterface range GigabitEthernet1\u002F0\u002F19-23\n  shutdown\n  switchport access vlan 999\n```\n\n### Step 4: Deploy Data Diode for Unidirectional Historian Replication\n\nInstall a hardware-enforced data diode between the operations zone and DMZ to ensure unidirectional data flow from OT to IT. Data diodes physically prevent any data from flowing back into the OT network.\n\n```python\n#!\u002Fusr\u002Fbin\u002Fenv python3\n\"\"\"Data Diode Configuration Validator.\n\nValidates that historian replication across the data diode\n(Waterfall Security, Owl Cyber Defense, or Siemens) is\nfunctioning correctly with unidirectional enforcement.\n\"\"\"\n\nimport socket\nimport struct\nimport time\nimport json\nfrom datetime import datetime\n\n\nclass DataDiodeValidator:\n    \"\"\"Validates data diode unidirectional enforcement.\"\"\"\n\n    def __init__(self, diode_tx_ip, diode_rx_ip, historian_port=5450):\n        self.tx_ip = diode_tx_ip  # OT side (transmit)\n        self.rx_ip = diode_rx_ip  # IT\u002FDMZ side (receive)\n        self.port = historian_port\n        self.results = []\n\n    def test_forward_flow(self):\n        \"\"\"Verify data flows from OT (TX) to DMZ (RX) through diode.\"\"\"\n        test_payload = f\"DIODE_TEST_{datetime.now().isoformat()}\"\n\n        try:\n            # Send test data to TX interface\n            sock = socket.socket(socket.AF_INET, socket.SOCK_DGRAM)\n            sock.settimeout(5)\n            sock.sendto(test_payload.encode(), (self.tx_ip, self.port))\n            sock.close()\n\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"PASS\",\n                \"detail\": f\"Data sent to TX interface {self.tx_ip}:{self.port}\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach TX interface: {e}\",\n            })\n\n    def test_reverse_flow_blocked(self):\n        \"\"\"Verify reverse flow (DMZ to OT) is physically blocked by diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(3)\n            result = sock.connect_ex((self.tx_ip, self.port))\n            sock.close()\n\n            if result != 0:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"PASS\",\n                    \"detail\": \"Reverse connection to OT side correctly rejected\",\n                })\n            else:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"CRITICAL_FAIL\",\n                    \"detail\": \"REVERSE FLOW POSSIBLE - Data diode bypass detected!\",\n                })\n        except (socket.timeout, ConnectionRefusedError):\n            self.results.append({\n                \"test\": \"reverse_flow_blocked\",\n                \"status\": \"PASS\",\n                \"detail\": \"Reverse connection timed out (expected with hardware diode)\",\n            })\n\n    def test_historian_replication_latency(self):\n        \"\"\"Measure replication latency across the data diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(10)\n            start = time.time()\n            sock.connect((self.rx_ip, self.port))\n            latency = (time.time() - start) * 1000\n            sock.close()\n\n            status = \"PASS\" if latency \u003C 1000 else \"WARN\"\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": status,\n                \"detail\": f\"Replication endpoint latency: {latency:.1f}ms\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach RX historian: {e}\",\n            })\n\n    def run_all_tests(self):\n        \"\"\"Run complete data diode validation suite.\"\"\"\n        print(\"=\" * 60)\n        print(\"DATA DIODE VALIDATION REPORT\")\n        print(\"=\" * 60)\n\n        self.test_forward_flow()\n        self.test_reverse_flow_blocked()\n        self.test_historian_replication_latency()\n\n        for r in self.results:\n            status_icon = \"+\" if r[\"status\"] == \"PASS\" else \"-\"\n            print(f\"  [{status_icon}] {r['test']}: {r['status']}\")\n            print(f\"      {r['detail']}\")\n\n        return self.results\n\n\nif __name__ == \"__main__\":\n    validator = DataDiodeValidator(\n        diode_tx_ip=\"10.30.1.100\",   # Operations zone TX\n        diode_rx_ip=\"172.16.1.100\",  # DMZ zone RX\n    )\n    validator.run_all_tests()\n```\n\n### Step 5: Validate Zone Architecture\n\nAfter implementation, validate the zone architecture by verifying that only authorized conduit traffic passes between zones and that all prohibited cross-zone paths are blocked.\n\n```bash\n# Validation test from Enterprise zone - should be blocked from reaching BPCS\nnmap -sT -p 502,44818,102,4840 10.20.0.0\u002F16 --reason\n# Expected: All ports filtered\u002Fclosed\n\n# Validation test from Operations zone - read-only Modbus should work\npython3 -c \"\nfrom pymodbus.client import ModbusTcpClient\nclient = ModbusTcpClient('10.20.1.10', port=502)\nclient.connect()\n# Read should succeed\nresult = client.read_holding_registers(0, 10, slave=1)\nprint(f'Read test: {\\\"PASS\\\" if not result.isError() else \\\"FAIL\\\"}')\n# Write should be blocked by firewall\nresult = client.write_register(0, 100, slave=1)\nprint(f'Write blocked: {\\\"PASS\\\" if result.isError() else \\\"FAIL - WRITE PERMITTED!\\\"}')\nclient.close()\n\"\n\n# Verify data diode blocks reverse traffic\nping -c 3 10.30.1.100  # From DMZ to OT - should timeout\n# Expected: 100% packet loss (hardware diode blocks ICMP)\n```\n\n## Key Concepts\n\n| Term | Definition |\n|------|------------|\n| Security Zone | A grouping of logical or physical assets that share common security requirements, as defined by IEC 62443-3-2 |\n| Conduit | A logical grouping of communication channels connecting two or more zones, subject to common security policies |\n| Security Level Target (SL-T) | The desired security level for a zone, ranging from SL 1 (casual violation) to SL 4 (state-sponsored attack) |\n| Data Diode | Hardware-enforced unidirectional network gateway that physically prevents data from flowing in the reverse direction |\n| Microsegmentation | Granular network segmentation at the device level, managing communication device-by-device based on roles and functions |\n| Deep Packet Inspection (DPI) | Firewall capability to inspect industrial protocol payloads (Modbus function codes, OPC UA service calls) beyond Layer 4 |\n| Defense in Depth | Layered security approach where multiple security controls protect assets at different levels of the architecture |\n\n## Tools & Systems\n\n- **Cisco ISA-3000**: Industrial security appliance providing OT-aware firewall, IPS, and VPN capabilities with Modbus, DNP3, and EtherNet\u002FIP inspection\n- **Fortinet FortiGate Rugged**: Ruggedized next-gen firewall with OT protocol support for industrial environments\n- **Palo Alto IoT\u002FOT Security**: Cloud-delivered OT security subscription providing device identification and protocol-aware policy enforcement\n- **Waterfall Security Solutions**: Hardware-enforced unidirectional security gateways (data diodes) for OT-to-IT data transfer\n- **Tofino Xenon**: Industrial security appliance providing deep packet inspection for Modbus, OPC, and EtherNet\u002FIP protocols\n\n## Common Scenarios\n\n### Scenario: Migrating Flat OT Network to Zone Architecture\n\n**Context**: A manufacturing plant operates all OT devices on a single VLAN (10.10.0.0\u002F16) with no segmentation between PLCs, HMIs, historians, and the corporate network. An IEC 62443 gap assessment identified this as a critical finding requiring zone implementation.\n\n**Approach**:\n1. Capture complete traffic baseline for 4 weeks using passive monitoring to identify all legitimate communication flows\n2. Classify all assets into Purdue levels and group into logical zones based on function and security requirements\n3. Design VLAN architecture with one VLAN per zone and inter-zone firewall rules based on observed legitimate traffic\n4. Deploy industrial firewalls at zone boundaries with initial \"monitor only\" mode (log but do not block)\n5. Analyze firewall logs for 2 weeks to identify any legitimate traffic that would be blocked\n6. Switch firewalls to enforcement mode during a scheduled maintenance window\n7. Validate that all process control communications function correctly post-segmentation\n8. Implement data diode between operations and DMZ for historian replication\n\n**Pitfalls**: Implementing zone firewalls without a complete traffic baseline will break unknown but legitimate communication paths. Scheduling zone cutover during production instead of maintenance windows risks process disruptions. Placing SIS controllers in the same zone as BPCS violates IEC 62443 safety system isolation requirements.\n\n## Output Format\n\n```\nIEC 62443 Zone Implementation Report\n=====================================\nFacility: [Name]\nImplementation Date: YYYY-MM-DD\nStandard: IEC 62443-3-2\u002F3-3\n\nZONE ARCHITECTURE:\n  Zone [ID]: [Name] (SL-T: [1-4])\n    Assets: [count]\n    Conduits: [list]\n    Controls: [firewall type, data diode, etc.]\n\nCONDUIT CONFIGURATION:\n  Conduit [ID]: [Zone A] \u003C-> [Zone B]\n    Protocols: [allowed protocols with direction]\n    Firewall Rules: [count allow \u002F count deny]\n    DPI Enabled: Yes\u002FNo\n\nVALIDATION RESULTS:\n  Cross-zone tests: [pass\u002Ffail count]\n  Prohibited path tests: [all blocked \u002F exceptions]\n  Protocol enforcement: [function code filtering verified]\n```\n","# Implementing IEC 62443 Security Zones\n\n## When to Use\n\n- When designing a greenfield OT network architecture for a new industrial facility\n- When retrofitting security zones into an existing flat OT network after an assessment finding\n- When implementing network segmentation to comply with IEC 62443-3-2 certification requirements\n- When upgrading from basic VLAN segmentation to policy-enforced zone\u002Fconduit architecture\n- When an IT\u002FOT convergence project requires defining security boundaries between enterprise and operational networks\n\n**Do not use** for IT-only network segmentation (see implementing-network-microsegmentation), for cloud-native workload segmentation (see securing-kubernetes-on-cloud), or for physical security zone design without a cyber component.\n\n## Prerequisites\n\n- Completed OT network security assessment with asset inventory and traffic flow analysis\n- Understanding of IEC 62443-3-2 zone\u002Fconduit design process and the Purdue Reference Model\n- Industrial firewalls capable of deep packet inspection for OT protocols (Palo Alto with OT Security, Fortinet OT, Cisco ISA-3000)\n- Network switches supporting VLANs, 802.1Q trunking, and port security\n- Approval from operations management for network architecture changes during maintenance windows\n\n## Workflow\n\n### Step 1: Perform Zone Partitioning Based on Risk Assessment\n\nPartition the IACS into zones based on functional requirements, security requirements, criticality, and consequence of compromise. Each zone contains assets with common security requirements.\n\n```yaml\n# IEC 62443-3-2 Zone Definition Document\nfacility: \"Petrochemical Refinery - Unit 3\"\nassessment_date: \"2026-02-23\"\nstandard: \"IEC 62443-3-2:2020\"\n\nzones:\n  - zone_id: \"Z1-SIS\"\n    name: \"Safety Instrumented Systems\"\n    purdue_level: 1\n    security_level_target: \"SL 3\"\n    criticality: \"Safety Critical\"\n    assets:\n      - \"Triconex 3008 Safety Controller (SIS-01)\"\n      - \"Triconex 3008 Safety Controller (SIS-02)\"\n      - \"SIS Engineering Workstation\"\n    security_requirements:\n      - \"Physically isolated from all other zones (air-gapped)\"\n      - \"Dedicated engineering workstation with removable media controls\"\n      - \"No remote access permitted under any circumstances\"\n      - \"Change management requires dual authorization\"\n    allowed_conduits: []  # No network conduits - fully air-gapped\n\n  - zone_id: \"Z2-BPCS\"\n    name: \"Basic Process Control System\"\n    purdue_level: \"1-2\"\n    security_level_target: \"SL 2\"\n    criticality: \"High\"\n    assets:\n      - \"Allen-Bradley ControlLogix PLCs (PLC-01 through PLC-12)\"\n      - \"Rockwell FactoryTalk View HMIs (HMI-01 through HMI-06)\"\n      - \"Engineering Workstation (EWS-01)\"\n    security_requirements:\n      - \"Industrial firewall at zone boundary with protocol inspection\"\n      - \"Read-only access from Level 3 for data acquisition\"\n      - \"Write access restricted to engineering workstation subnet\"\n      - \"USB ports disabled on HMIs\"\n    allowed_conduits: [\"C1-BPCS-OPS\"]\n\n  - zone_id: \"Z3-OPS\"\n    name: \"Site Operations\"\n    purdue_level: 3\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"OSIsoft PI Historian (HIST-01)\"\n      - \"OPC UA Server (OPC-01)\"\n      - \"MES Application Server (MES-01)\"\n      - \"Alarm Management Server (ALM-01)\"\n    security_requirements:\n      - \"Firewall between operations and control zones\"\n      - \"Firewall between operations and DMZ\"\n      - \"No direct internet access\"\n      - \"Antivirus with OT-approved signatures\"\n    allowed_conduits: [\"C1-BPCS-OPS\", \"C2-OPS-DMZ\"]\n\n  - zone_id: \"Z4-DMZ\"\n    name: \"Industrial Demilitarized Zone\"\n    purdue_level: 3.5\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"PI-to-PI Interface (DMZ-HIST-01)\"\n      - \"Patch Management Server (DMZ-WSUS-01)\"\n      - \"Remote Access Jump Server (DMZ-JUMP-01)\"\n      - \"Data Diode - Waterfall Security (DMZ-DD-01)\"\n    security_requirements:\n      - \"Dual-homed firewalls on both sides\"\n      - \"No direct traffic traversal - all connections terminate in DMZ\"\n      - \"Data diode for unidirectional historian replication\"\n      - \"Jump server with MFA for remote access\"\n    allowed_conduits: [\"C2-OPS-DMZ\", \"C3-DMZ-ENT\"]\n\n  - zone_id: \"Z5-ENT\"\n    name: \"Enterprise Network\"\n    purdue_level: 4\n    security_level_target: \"SL 1\"\n    criticality: \"Low (from OT perspective)\"\n    assets:\n      - \"Corporate systems accessing OT data\"\n    security_requirements:\n      - \"Firewall between enterprise and DMZ\"\n      - \"No direct access to any OT zone below DMZ\"\n    allowed_conduits: [\"C3-DMZ-ENT\"]\n\nconduits:\n  - conduit_id: \"C1-BPCS-OPS\"\n    name: \"Control-to-Operations Conduit\"\n    connects: [\"Z2-BPCS\", \"Z3-OPS\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"OPC UA\"\n        port: 4840\n        direction: \"Z2 -> Z3 (read only)\"\n        security_mode: \"SignAndEncrypt\"\n      - protocol: \"Modbus\u002FTCP\"\n        port: 502\n        direction: \"Z3 -> Z2 (read only, FC 3\u002F4 only)\"\n        security_mode: \"Firewall-enforced function code filtering\"\n    controls:\n      - \"Industrial firewall with OT protocol DPI\"\n      - \"Allowlisted source\u002Fdestination IP pairs\"\n      - \"Function code filtering (block all write operations from L3)\"\n      - \"Connection rate limiting\"\n\n  - conduit_id: \"C2-OPS-DMZ\"\n    name: \"Operations-to-DMZ Conduit\"\n    connects: [\"Z3-OPS\", \"Z4-DMZ\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"PI-to-PI\"\n        port: 5450\n        direction: \"Z3 -> Z4 (unidirectional via data diode)\"\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z4 -> Z3 (patch downloads only)\"\n    controls:\n      - \"Data diode for historian replication (Waterfall Security)\"\n      - \"Firewall with application-layer inspection\"\n      - \"Patch server pulls only from approved vendor repositories\"\n\n  - conduit_id: \"C3-DMZ-ENT\"\n    name: \"DMZ-to-Enterprise Conduit\"\n    connects: [\"Z4-DMZ\", \"Z5-ENT\"]\n    security_level: \"SL 1\"\n    protocols_allowed:\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z5 -> Z4 (historian read, remote access portal)\"\n      - protocol: \"RDP\"\n        port: 3389\n        direction: \"Z5 -> Z4 (jump server with MFA)\"\n    controls:\n      - \"Next-gen firewall with SSL inspection\"\n      - \"MFA required for all remote access sessions\"\n      - \"Session recording on jump server\"\n```\n\n### Step 2: Configure Industrial Firewalls for Zone Boundaries\n\nDeploy and configure industrial-grade firewalls at each zone boundary with OT protocol-aware deep packet inspection.\n\n```bash\n# Cisco ISA-3000 Industrial Firewall Configuration\n# Conduit C1: BPCS (Zone 2) \u003C-> Operations (Zone 3)\n\n# Define zone interfaces\ninterface GigabitEthernet1\u002F1\n  nameif zone-bpcs\n  security-level 90\n  ip address 10.20.1.1 255.255.0.0\n\ninterface GigabitEthernet1\u002F2\n  nameif zone-ops\n  security-level 70\n  ip address 10.30.1.1 255.255.0.0\n\n# OPC UA from BPCS to Operations (read-only data flow)\naccess-list BPCS-to-OPS extended permit tcp 10.20.0.0 255.255.0.0 host 10.30.1.50 eq 4840\n# Modbus read from Operations historian to PLCs (FC 3,4 only)\naccess-list OPS-to-BPCS extended permit tcp host 10.30.1.50 10.20.0.0 255.255.0.0 eq 502\n\n# Deny all other traffic between zones\naccess-list BPCS-to-OPS extended deny ip any any log\naccess-list OPS-to-BPCS extended deny ip any any log\n\n# Apply access lists\naccess-group BPCS-to-OPS in interface zone-bpcs\naccess-group OPS-to-BPCS in interface zone-ops\n\n# Enable Modbus protocol inspection with function code filtering\npolicy-map type inspect modbus MODBUS-INSPECT\n  parameters\n    # Allow read operations only from Operations zone\n    match func-code read-coils\n    match func-code read-discrete-inputs\n    match func-code read-holding-registers\n    match func-code read-input-registers\n    # Block all write function codes\n    match func-code force-single-coil  action drop log\n    match func-code preset-single-register  action drop log\n    match func-code force-multiple-coils  action drop log\n    match func-code preset-multiple-registers  action drop log\n\n# Apply to service policy\npolicy-map global_policy\n  class inspection_default\n    inspect modbus MODBUS-INSPECT\n\n# Logging to OT SIEM\nlogging host zone-ops 10.30.1.60\nlogging trap informational\nlogging enable\n```\n\n### Step 3: Implement VLAN Segmentation at Switch Level\n\nConfigure network switches to enforce zone boundaries at Layer 2, preventing broadcast domain overlap between Purdue levels.\n\n```bash\n# Cisco Industrial Ethernet Switch Configuration\n# Zone-based VLAN assignment\n\n# VLAN definitions aligned with zones\nvlan 10\n  name Z1-SIS-Safety\nvlan 20\n  name Z2-BPCS-Control\nvlan 30\n  name Z3-OPS-Operations\nvlan 35\n  name Z4-DMZ\nvlan 40\n  name Z5-Enterprise\n\n# PLC ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F1-12\n  description PLC connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation shutdown\n  spanning-tree portfast\n  spanning-tree bpduguard enable\n  no cdp enable\n  no lldp transmit\n\n# HMI ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F13-18\n  description HMI connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation restrict\n  spanning-tree portfast\n\n# Trunk to industrial firewall\ninterface GigabitEthernet1\u002F0\u002F24\n  description Trunk to ISA-3000 Firewall\n  switchport mode trunk\n  switchport trunk allowed vlan 20,30,35\n  switchport trunk native vlan 999\n\n# Disable unused ports\ninterface range GigabitEthernet1\u002F0\u002F19-23\n  shutdown\n  switchport access vlan 999\n```\n\n### Step 4: Deploy Data Diode for Unidirectional Historian Replication\n\nInstall a hardware-enforced data diode between the operations zone and DMZ to ensure unidirectional data flow from OT to IT. Data diodes physically prevent any data from flowing back into the OT network.\n\n```python\n#!\u002Fusr\u002Fbin\u002Fenv python3\n\"\"\"Data Diode Configuration Validator.\n\nValidates that historian replication across the data diode\n(Waterfall Security, Owl Cyber Defense, or Siemens) is\nfunctioning correctly with unidirectional enforcement.\n\"\"\"\n\nimport socket\nimport struct\nimport time\nimport json\nfrom datetime import datetime\n\n\nclass DataDiodeValidator:\n    \"\"\"Validates data diode unidirectional enforcement.\"\"\"\n\n    def __init__(self, diode_tx_ip, diode_rx_ip, historian_port=5450):\n        self.tx_ip = diode_tx_ip  # OT side (transmit)\n        self.rx_ip = diode_rx_ip  # IT\u002FDMZ side (receive)\n        self.port = historian_port\n        self.results = []\n\n    def test_forward_flow(self):\n        \"\"\"Verify data flows from OT (TX) to DMZ (RX) through diode.\"\"\"\n        test_payload = f\"DIODE_TEST_{datetime.now().isoformat()}\"\n\n        try:\n            # Send test data to TX interface\n            sock = socket.socket(socket.AF_INET, socket.SOCK_DGRAM)\n            sock.settimeout(5)\n            sock.sendto(test_payload.encode(), (self.tx_ip, self.port))\n            sock.close()\n\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"PASS\",\n                \"detail\": f\"Data sent to TX interface {self.tx_ip}:{self.port}\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach TX interface: {e}\",\n            })\n\n    def test_reverse_flow_blocked(self):\n        \"\"\"Verify reverse flow (DMZ to OT) is physically blocked by diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(3)\n            result = sock.connect_ex((self.tx_ip, self.port))\n            sock.close()\n\n            if result != 0:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"PASS\",\n                    \"detail\": \"Reverse connection to OT side correctly rejected\",\n                })\n            else:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"CRITICAL_FAIL\",\n                    \"detail\": \"REVERSE FLOW POSSIBLE - Data diode bypass detected!\",\n                })\n        except (socket.timeout, ConnectionRefusedError):\n            self.results.append({\n                \"test\": \"reverse_flow_blocked\",\n                \"status\": \"PASS\",\n                \"detail\": \"Reverse connection timed out (expected with hardware diode)\",\n            })\n\n    def test_historian_replication_latency(self):\n        \"\"\"Measure replication latency across the data diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(10)\n            start = time.time()\n            sock.connect((self.rx_ip, self.port))\n            latency = (time.time() - start) * 1000\n            sock.close()\n\n            status = \"PASS\" if latency \u003C 1000 else \"WARN\"\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": status,\n                \"detail\": f\"Replication endpoint latency: {latency:.1f}ms\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach RX historian: {e}\",\n            })\n\n    def run_all_tests(self):\n        \"\"\"Run complete data diode validation suite.\"\"\"\n        print(\"=\" * 60)\n        print(\"DATA DIODE VALIDATION REPORT\")\n        print(\"=\" * 60)\n\n        self.test_forward_flow()\n        self.test_reverse_flow_blocked()\n        self.test_historian_replication_latency()\n\n        for r in self.results:\n            status_icon = \"+\" if r[\"status\"] == \"PASS\" else \"-\"\n            print(f\"  [{status_icon}] {r['test']}: {r['status']}\")\n            print(f\"      {r['detail']}\")\n\n        return self.results\n\n\nif __name__ == \"__main__\":\n    validator = DataDiodeValidator(\n        diode_tx_ip=\"10.30.1.100\",   # Operations zone TX\n        diode_rx_ip=\"172.16.1.100\",  # DMZ zone RX\n    )\n    validator.run_all_tests()\n```\n\n### Step 5: Validate Zone Architecture\n\nAfter implementation, validate the zone architecture by verifying that only authorized conduit traffic passes between zones and that all prohibited cross-zone paths are blocked.\n\n```bash\n# Validation test from Enterprise zone - should be blocked from reaching BPCS\nnmap -sT -p 502,44818,102,4840 10.20.0.0\u002F16 --reason\n# Expected: All ports filtered\u002Fclosed\n\n# Validation test from Operations zone - read-only Modbus should work\npython3 -c \"\nfrom pymodbus.client import ModbusTcpClient\nclient = ModbusTcpClient('10.20.1.10', port=502)\nclient.connect()\n# Read should succeed\nresult = client.read_holding_registers(0, 10, slave=1)\nprint(f'Read test: {\\\"PASS\\\" if not result.isError() else \\\"FAIL\\\"}')\n# Write should be blocked by firewall\nresult = client.write_register(0, 100, slave=1)\nprint(f'Write blocked: {\\\"PASS\\\" if result.isError() else \\\"FAIL - WRITE PERMITTED!\\\"}')\nclient.close()\n\"\n\n# Verify data diode blocks reverse traffic\nping -c 3 10.30.1.100  # From DMZ to OT - should timeout\n# Expected: 100% packet loss (hardware diode blocks ICMP)\n```\n\n## Key Concepts\n\n| Term | Definition |\n|------|------------|\n| Security Zone | A grouping of logical or physical assets that share common security requirements, as defined by IEC 62443-3-2 |\n| Conduit | A logical grouping of communication channels connecting two or more zones, subject to common security policies |\n| Security Level Target (SL-T) | The desired security level for a zone, ranging from SL 1 (casual violation) to SL 4 (state-sponsored attack) |\n| Data Diode | Hardware-enforced unidirectional network gateway that physically prevents data from flowing in the reverse direction |\n| Microsegmentation | Granular network segmentation at the device level, managing communication device-by-device based on roles and functions |\n| Deep Packet Inspection (DPI) | Firewall capability to inspect industrial protocol payloads (Modbus function codes, OPC UA service calls) beyond Layer 4 |\n| Defense in Depth | Layered security approach where multiple security controls protect assets at different levels of the architecture |\n\n## Tools & Systems\n\n- **Cisco ISA-3000**: Industrial security appliance providing OT-aware firewall, IPS, and VPN capabilities with Modbus, DNP3, and EtherNet\u002FIP inspection\n- **Fortinet FortiGate Rugged**: Ruggedized next-gen firewall with OT protocol support for industrial environments\n- **Palo Alto IoT\u002FOT Security**: Cloud-delivered OT security subscription providing device identification and protocol-aware policy enforcement\n- **Waterfall Security Solutions**: Hardware-enforced unidirectional security gateways (data diodes) for OT-to-IT data transfer\n- **Tofino Xenon**: Industrial security appliance providing deep packet inspection for Modbus, OPC, and EtherNet\u002FIP protocols\n\n## Common Scenarios\n\n### Scenario: Migrating Flat OT Network to Zone Architecture\n\n**Context**: A manufacturing plant operates all OT devices on a single VLAN (10.10.0.0\u002F16) with no segmentation between PLCs, HMIs, historians, and the corporate network. An IEC 62443 gap assessment identified this as a critical finding requiring zone implementation.\n\n**Approach**:\n1. Capture complete traffic baseline for 4 weeks using passive monitoring to identify all legitimate communication flows\n2. Classify all assets into Purdue levels and group into logical zones based on function and security requirements\n3. Design VLAN architecture with one VLAN per zone and inter-zone firewall rules based on observed legitimate traffic\n4. Deploy industrial firewalls at zone boundaries with initial \"monitor only\" mode (log but do not block)\n5. Analyze firewall logs for 2 weeks to identify any legitimate traffic that would be blocked\n6. Switch firewalls to enforcement mode during a scheduled maintenance window\n7. Validate that all process control communications function correctly post-segmentation\n8. Implement data diode between operations and DMZ for historian replication\n\n**Pitfalls**: Implementing zone firewalls without a complete traffic baseline will break unknown but legitimate communication paths. Scheduling zone cutover during production instead of maintenance windows risks process disruptions. Placing SIS controllers in the same zone as BPCS violates IEC 62443 safety system isolation requirements.\n\n## Output Format\n\n```\nIEC 62443 Zone Implementation Report\n=====================================\nFacility: [Name]\nImplementation Date: YYYY-MM-DD\nStandard: IEC 62443-3-2\u002F3-3\n\nZONE ARCHITECTURE:\n  Zone [ID]: [Name] (SL-T: [1-4])\n    Assets: [count]\n    Conduits: [list]\n    Controls: [firewall type, data diode, etc.]\n\nCONDUIT CONFIGURATION:\n  Conduit [ID]: [Zone A] \u003C-> [Zone B]\n    Protocols: [allowed protocols with direction]\n    Firewall Rules: [count allow \u002F count deny]\n    DPI Enabled: Yes\u002FNo\n\nVALIDATION RESULTS:\n  Cross-zone tests: [pass\u002Ffail count]\n  Prohibited path tests: [all blocked \u002F exceptions]\n  Protocol enforcement: [function code filtering verified]\n```\n",{"name":5,"note":25,"tags":26,"author":34,"domain":35,"source":36,"license":15,"version":37,"nist_csf":38,"subdomain":43,"description":44,"mitre_attack":45,"source_commit":51},"Vendored verbatim from an external Apache-2.0 security-skill library, pinned by commit. Exceeds the internal 300-line skill guideline (agent-code-constraints.md) -- kept as-is because this is vendored reference material (forensics\u002Fthreat-intel procedure), not Yana AI-authored content, and trimming would damage technical accuracy.",[27,28,29,30,31,32,33],"ot-security","ics","scada","industrial-control","iec62443","network-segmentation","zones-conduits","mahipal","cybersecurity","https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills","1.0.0",[39,40,41,42],"PR.IR-01","DE.CM-01","ID.AM-05","GV.OC-02","ot-ics-security","This skill covers designing and implementing security zones and conduits for industrial automation and control systems (IACS) per IEC 62443-3-2. It addresses zone partitioning based on risk assessment, assigning Security Level targets (SL-T), designing conduit security controls, implementing microsegmentation with industrial firewalls, and validating zone architecture through traffic analysis and penetration testing against the Purdue Reference Model.\n",[46,47,48,49,50],"T1078","T1190","T1059","T0816","T0836","04450304b12645cb2b974ab96d28c0664758a88d","main","481dcd7dd2e288b9d627a2bd017db70e64e6c6fa","core\u002Fskills\u002Fimplementing-iec-62443-security-zones",2,"https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI","https:\u002F\u002Fyana.vutam.link\u002F","https:\u002F\u002Fgithub.com\u002FHoronomos-laps","https:\u002F\u002Fyana.vutam.link","An open-source governed runtime & execution environment for multi-agent AI systems.","2026-11-14 13:24:09",{"source":8,"skillName":5,"commands":63,"prompt":73,"zipAvailable":74},[64,67,70],{"tool":65,"command":66},"npx","npx skills add Horonomos-laps\u002FYana-AI --skill implementing-iec-62443-security-zones",{"tool":68,"command":69},"bunx","bunx skills add Horonomos-laps\u002FYana-AI --skill implementing-iec-62443-security-zones",{"tool":71,"command":72},"pnpm","pnpm dlx skills add Horonomos-laps\u002FYana-AI --skill implementing-iec-62443-security-zones","安装技能，技能地址：https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002FSKILL.md",true,[76,80,86],{"path":77,"resourceType":77,"resourceTypeDesc":78,"sizeBytes":79,"sourceHtmlUrl":16},"LICENSE","许可证",11255,{"path":81,"resourceType":82,"resourceTypeDesc":83,"sizeBytes":84,"sourceHtmlUrl":85},"references\u002Fapi-reference.md","REFERENCE","参考文档",1770,"https:\u002F\u002Fgithub.com\u002Fyanacuti1121\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002Freferences\u002Fapi-reference.md",{"path":87,"resourceType":88,"resourceTypeDesc":89,"sizeBytes":90,"sourceHtmlUrl":91},"scripts\u002Fagent.py","SCRIPT","脚本",9009,"https:\u002F\u002Fgithub.com\u002Fyanacuti1121\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002Fscripts\u002Fagent.py",[93,101,108,116,124,132],{"skillNo":94,"name":95,"nameZh":6,"description":96,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":97,"licenseFileUrl":6,"sourceHtmlUrl":98,"categories":99,"keywords":100,"publishedAt":20},"01M735GKET5YVYKAY62W2P5YXB","openai--sentry--sentry","Use when the user asks to inspect Sentry issues or events, summarize recent production errors, or pull basic Sentry health data via the Sentry API; perform read-only queries with the bundled script and require `SENTRY_AUTH_TOKEN`.","MIT","https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002F.claude\u002Fskills\u002Fopenai--sentry--sentry\u002FSKILL.md",[],[],{"skillNo":102,"name":103,"nameZh":6,"description":104,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":105,"categories":106,"keywords":107,"publishedAt":20},"01M73DCAP83T17HY7SMGK7MGFE","ito-basket-compare","Compare Itô prediction-market baskets against a user's knowledge base, portfolio notes, financial context, watchlist, or research thesis. Use for read-only basket comparison and gap analysis without investment advice or live trading.","https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fito-basket-compare\u002FSKILL.md",[],[],{"skillNo":109,"name":110,"nameZh":6,"description":111,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":112,"sourceHtmlUrl":113,"categories":114,"keywords":115,"publishedAt":20},"01M734CYEMZFDR3KH6SW0JP8TD","implementing-network-traffic-baselining","Build network traffic baselines from NetFlow\u002FIPFIX data using Python pandas for statistical analysis, z-score anomaly detection, and hourly\u002Fdaily traffic pattern profiling","https:\u002F\u002Fgithub.com\u002Fyanacuti1121\u002FYana-AI\u002Fblob\u002Fmain\u002F.claude\u002Fskills\u002Fimplementing-network-traffic-baselining\u002FLICENSE","https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002F.claude\u002Fskills\u002Fimplementing-network-traffic-baselining\u002FSKILL.md",[],[],{"skillNo":117,"name":118,"nameZh":6,"description":119,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":120,"sourceHtmlUrl":121,"categories":122,"keywords":123,"publishedAt":20},"01M73ASZ6NJRJM44Z2P84NGQ3Q","detecting-evasion-techniques-in-endpoint-logs","Detects defense evasion techniques used by adversaries in endpoint logs including log tampering, timestomping, process injection, and security tool disabling. Use when investigating suspicious endpoint behavior, building detection rules for evasion tactics, or conducting threat hunting for stealthy adversary activity. Activates for requests involving evasion detection, defense evasion analysis, log tampering detection, or MITRE ATT&CK TA0005.","https:\u002F\u002Fgithub.com\u002Fyanacuti1121\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fdetecting-evasion-techniques-in-endpoint-logs\u002FLICENSE","https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002Fcore\u002Fskills\u002Fdetecting-evasion-techniques-in-endpoint-logs\u002FSKILL.md",[],[],{"skillNo":125,"name":126,"nameZh":6,"description":127,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":128,"sourceHtmlUrl":129,"categories":130,"keywords":131,"publishedAt":20},"01M734AFNXD06Z78QRK0VKGT7Q","implementing-microsegmentation-with-guardicore","Implementing microsegmentation using Akamai Guardicore Segmentation to map application dependencies, create granular network policies, visualize east-west traffic flows, and enforce least-privilege communication between workloads across data centers and cloud.","https:\u002F\u002Fgithub.com\u002Fyanacuti1121\u002FYana-AI\u002Fblob\u002Fmain\u002F.claude\u002Fskills\u002Fimplementing-microsegmentation-with-guardicore\u002FLICENSE","https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002F.claude\u002Fskills\u002Fimplementing-microsegmentation-with-guardicore\u002FSKILL.md",[],[],{"skillNo":133,"name":134,"nameZh":6,"description":6,"descriptionZh":6,"repositoryFullName":8,"ownerLogin":9,"ownerAvatarUrl":10,"ownerAccountNo":11,"ownerDisplayName":12,"repositoryNo":13,"starsCount":14,"licenseSpdxId":15,"licenseFileUrl":6,"sourceHtmlUrl":135,"categories":136,"keywords":137,"publishedAt":20},"01M736TK27QMCXK0DVCH25SJN5","ramdisk-tmpfs-patterns","https:\u002F\u002Fgithub.com\u002FHoronomos-laps\u002FYana-AI\u002Fblob\u002Fmain\u002F.claude\u002Fskills\u002Framdisk-tmpfs-patterns\u002FSKILL.md",[],[]]