review
Review Playwright tests for quality. Use when user says "review tests", "check test quality", "audit tests", "improve tests", "test code review", or "playwright best practices check".
- License 许可
- MIT
- 最近更新
- 2026-04-01
- Stars
- ★ 3
- Forks
- 2
01 前言 Front Matter
- name
- review
- description
- Review Playwright tests for quality. Use when user says "review tests", "check test quality", "audit tests", "improve tests", "test code review", or "playwright best practices check".
02 资源文件 1
- 参考文档anti-patterns.md4.2 KB
03 SKILL.md 正文
Review Playwright Tests
Systematically review Playwright test files for anti-patterns, missed best practices, and coverage gaps.
Input
$ARGUMENTS can be:
- A file path: review that specific test file
- A directory: review all test files in the directory
- Empty: review all tests in the project's
testDir
Steps
1. Gather Context
- Read
playwright.config.tsfor project settings - List all
*.spec.ts/*.spec.jsfiles in scope - If reviewing a single file, also check related page objects and fixtures
2. Check Each File Against Anti-Patterns
Load anti-patterns.md from this skill directory. Check for all 20 anti-patterns.
Critical (must fix):
waitForTimeout()usage- Non-web-first assertions (
expect(await ...)) - Hardcoded URLs instead of
baseURL - CSS/XPath selectors when role-based exists
- Missing
awaiton Playwright calls - Shared mutable state between tests
- Test execution order dependencies
Warning (should fix):
8. Tests longer than 50 lines (consider splitting)
9. Magic strings without named constants
10. Missing error/edge case tests
11. page.evaluate() for things locators can do
12. Nested test.describe() more than 2 levels deep
13. Generic test names ("should work", "test 1")
Info (consider):
14. No page objects for pages with 5+ locators
15. Inline test data instead of factory/fixture
16. Missing accessibility assertions
17. No visual regression tests for UI-heavy pages
18. Console error assertions not checked
19. Network idle waits instead of specific assertions
20. Missing test.describe() grouping
3. Score Each File
Rate 1-10 based on:
- 9-10: Production-ready, follows all golden rules
- 7-8: Good, minor improvements possible
- 5-6: Functional but has anti-patterns
- 3-4: Significant issues, likely flaky
- 1-2: Needs rewrite
4. Generate Review Report
For each file:
## <filename> — Score: X/10
### Critical
- Line 15: `waitForTimeout(2000)` → use `expect(locator).toBeVisible()`
- Line 28: CSS selector `.btn-submit` → `getByRole('button', { name: "submit" })`
### Warning
- Line 42: Test name "test login" → "should redirect to dashboard after login"
### Suggestions
- Consider adding error case: what happens with invalid credentials?
5. For Project-Wide Review
If reviewing an entire test suite:
- Spawn sub-agents per file for parallel review (up to 5 concurrent)
- Or use
/batchfor very large suites - Aggregate results into a summary table
6. Offer Fixes
For each critical issue, provide the corrected code. Ask user: "Apply these fixes? [Yes/No]"
If yes, apply all fixes using Edit tool.
Output
- File-by-file review with scores
- Summary: total files, average score, critical issue count
- Actionable fix list
- Coverage gaps identified (pages/features with no tests)
04 同仓库更多 Skills
soc2-compliance
Use when the user asks to prepare for SOC 2 audits, map Trust Service Criteria, build control matrices, collect audit evidence, perform gap analysis, or assess SOC 2 Type I vs Type II readiness.
risk-management-specialist
Medical device risk management specialist implementing ISO 14971 throughout product lifecycle. Provides risk analysis, risk evaluation, risk control, and post-production information analysis. Use when user mentions risk management, ISO 14971, risk analysis, FMEA, fault tree analysis, hazard identification, risk control, risk matrix, benefit-risk analysis, residual risk, risk acceptability, or post-market risk.
regulatory-affairs-head
Senior Regulatory Affairs Manager for HealthTech and MedTech companies. Prepares FDA 510(k), De Novo, and PMA submission packages; analyzes regulatory pathways for new medical devices; drafts responses to FDA deficiency letters and Notified Body queries; develops CE marking technical documentation under EU MDR 2017/745; coordinates multi-market approval strategies across FDA, EU, Health Canada, PMDA, and NMPA; and maintains regulatory intelligence on evolving standards. Use when users need to plan or execute FDA submissions, navigate 510(k) or PMA approval processes, achieve CE marking, prepare pre-submission meeting materials, write regulatory strategy documents, respond to agency queries, or manage compliance documentation for medical device market access.
quality-manager-qms-iso13485
ISO 13485 Quality Management System implementation and maintenance for medical device organizations. Provides QMS design, documentation control, internal auditing, CAPA management, and certification support. Use when working with medical device quality systems, preparing for ISO 13485 audits, managing regulatory compliance documentation, setting up corrective actions, or building audit preparation programs. Useful for quality management, audit preparation, regulatory compliance, medical device documentation, and corrective action workflows.
quality-manager-qmr
Senior Quality Manager Responsible Person (QMR) for HealthTech and MedTech companies. Provides quality system governance, management review leadership, regulatory compliance oversight, and quality performance monitoring per ISO 13485 Clause 5.5.2.
quality-documentation-manager
Document control system management for medical device QMS. Covers document numbering, version control, change management, and 21 CFR Part 11 compliance. Use for document control procedures, change control workflow, document numbering, version management, electronic signature compliance, or regulatory documentation review.