AGENT SKILL

VLAN 网络分段配置

configuring-network-segmentation-with-vlans

在管理型交换机上设计并实施基于 VLAN(802.1Q)的网络分段,以隔离企业、服务器、DMZ、访客和 IoT 等区域,并限制横向移动路径。适用于将企业网络划分为隔离的安全区域、满足网络隔离的合规要求(PCI-DSS、HIPAA、SOC 2),或降低安全事件的影响范围(爆炸半径)。

License 许可
Apache-2.0
最近更新
2026-08-31
Stars
★ 3.6w
Forks
4.4k

01 前言 Front Matter

name
configuring-network-segmentation-with-vlans
tags
[ "network-security", "vlan", "network-segmentation", "switch-security", "802.1q" ]
author
mahipal
domain
cybersecurity
license
Apache-2.0
version
1.0
nist_csf
[ "PR.IR-01", "DE.CM-01", "ID.AM-03", "PR.DS-02" ]
subdomain
network-security
description
Designs and implements VLAN-based (802.1Q) network segmentation on managed switches to isolate zones such as corporate, servers, DMZ, guest, and IoT, and to limit lateral movement paths. Use when segmenting an enterprise network into isolated security zones, meeting compliance mandates (PCI-DSS, HIPAA, SOC 2) for network isolation, or reducing blast radius from a security incident.
mitre_attack
[ "T1046", "T1040", "T1557.002", "T1021", "T1018" ]

02 资源文件 3

03 SKILL.md 正文

Configuring Network Segmentation with VLANs

When to Use

  • Segmenting an enterprise network into isolated security zones (corporate, servers, DMZ, guest, IoT)
  • Meeting compliance requirements (PCI-DSS, HIPAA, SOC 2) that mandate network isolation for sensitive data
  • Reducing blast radius of security incidents by preventing lateral movement between network segments
  • Isolating high-risk devices (IoT, BYOD, legacy systems) from critical infrastructure
  • Implementing defense-in-depth by combining VLANs with firewall rules and access control lists

Do not use VLANs as the sole security control without Layer 3 filtering, for isolating networks that require air-gapping, or without proper switch hardening against VLAN hopping attacks.

Prerequisites

  • Managed switches supporting 802.1Q VLAN trunking (Cisco Catalyst, HP Aruba, Juniper EX, etc.)
  • Layer 3 switch or firewall for inter-VLAN routing and access control
  • Network design document specifying VLAN assignments, IP subnets, and traffic flow requirements
  • Console or SSH access to switches with privileged configuration mode
  • Understanding of 802.1Q trunking, STP, and inter-VLAN routing concepts

Workflow

Step 1: Design the VLAN Architecture

# Define VLANs based on security zones and function

VLAN Plan:
  VLAN 10  - CORPORATE    (10.10.10.0/24)  - Employee workstations
  VLAN 20  - SERVERS      (10.10.20.0/24)  - Internal servers
  VLAN 30  - DMZ          (10.10.30.0/24)  - Internet-facing servers
  VLAN 40  - GUEST        (10.10.40.0/24)  - Guest WiFi
  VLAN 50  - IOT          (10.10.50.0/24)  - IoT/OT devices
  VLAN 60  - VOIP         (10.10.60.0/24)  - VoIP phones
  VLAN 100 - MANAGEMENT   (10.10.100.0/24) - Switch/AP management
  VLAN 999 - QUARANTINE   (10.10.99.0/24)  - Isolated/compromised hosts
  VLAN 998 - NATIVE_UNUSED                  - Native VLAN (no traffic)

# Traffic flow matrix:
# CORPORATE -> SERVERS: Allowed (specific ports)
# CORPORATE -> DMZ: Allowed (HTTP/HTTPS only)
# CORPORATE -> GUEST: Denied
# CORPORATE -> IOT: Denied
# GUEST -> Any Internal: Denied
# IOT -> SERVERS: Allowed (specific ports to specific hosts only)
# DMZ -> SERVERS: Allowed (database ports only)
# MANAGEMENT -> All: Allowed (from management stations only)

Step 2: Configure VLANs on Cisco Catalyst Switch

! Enter configuration mode
enable
configure terminal

! Create VLANs
vlan 10
  name CORPORATE
  exit
vlan 20
  name SERVERS
  exit
vlan 30
  name DMZ
  exit
vlan 40
  name GUEST
  exit
vlan 50
  name IOT
  exit
vlan 60
  name VOIP
  exit
vlan 100
  name MANAGEMENT
  exit
vlan 998
  name NATIVE_UNUSED
  exit
vlan 999
  name QUARANTINE
  exit

! Configure access ports for workstations (VLAN 10)
interface range GigabitEthernet1/0/1-24
  switchport mode access
  switchport access vlan 10
  switchport nonegotiate
  spanning-tree portfast
  spanning-tree bpduguard enable
  no shutdown
  exit

! Configure access ports for servers (VLAN 20)
interface range GigabitEthernet1/0/25-36
  switchport mode access
  switchport access vlan 20
  switchport nonegotiate
  spanning-tree portfast
  spanning-tree bpduguard enable
  no shutdown
  exit

! Configure trunk ports to other switches
interface GigabitEthernet1/0/48
  switchport mode trunk
  switchport trunk encapsulation dot1q
  switchport trunk native vlan 998
  switchport trunk allowed vlan 10,20,30,40,50,60,100
  switchport nonegotiate
  no shutdown
  exit

! Configure trunk to firewall/router
interface GigabitEthernet1/0/47
  switchport mode trunk
  switchport trunk encapsulation dot1q
  switchport trunk native vlan 998
  switchport trunk allowed vlan 10,20,30,40,50,60,100
  switchport nonegotiate
  no shutdown
  exit

! Shutdown unused ports
interface range GigabitEthernet1/0/37-46
  shutdown
  switchport mode access
  switchport access vlan 999
  exit

Step 3: Harden Switch Against VLAN Hopping

! Disable DTP on all ports (prevents switch spoofing)
interface range GigabitEthernet1/0/1-46
  switchport nonegotiate
  exit

! Set native VLAN to unused VLAN on all trunks
interface range GigabitEthernet1/0/47-48
  switchport trunk native vlan 998
  exit

! Enable DHCP Snooping
ip dhcp snooping
ip dhcp snooping vlan 10,20,30,40,50,60
interface GigabitEthernet1/0/47
  ip dhcp snooping trust
  exit

! Enable Dynamic ARP Inspection
ip arp inspection vlan 10,20,30,40,50,60
interface GigabitEthernet1/0/47
  ip arp inspection trust
  exit

! Enable IP Source Guard (prevents IP spoofing)
interface range GigabitEthernet1/0/1-36
  ip verify source
  exit

! Enable Port Security
interface range GigabitEthernet1/0/1-24
  switchport port-security
  switchport port-security maximum 2
  switchport port-security violation restrict
  switchport port-security aging time 60
  exit

! Set VTP to transparent mode (prevents VTP attacks)
vtp mode transparent

! Enable BPDU Guard globally
spanning-tree portfast bpduguard default

! Enable Storm Control
interface range GigabitEthernet1/0/1-36
  storm-control broadcast level 10
  storm-control multicast level 10
  storm-control action shutdown
  exit

Step 4: Configure Inter-VLAN Routing with ACLs

! On the Layer 3 switch or firewall, configure SVIs
interface Vlan10
  ip address 10.10.10.1 255.255.255.0
  no shutdown
  exit
interface Vlan20
  ip address 10.10.20.1 255.255.255.0
  no shutdown
  exit
interface Vlan30
  ip address 10.10.30.1 255.255.255.0
  no shutdown
  exit
interface Vlan40
  ip address 10.10.40.1 255.255.255.0
  no shutdown
  exit
interface Vlan50
  ip address 10.10.50.1 255.255.255.0
  no shutdown
  exit

! ACL: Corporate to Servers (allow specific services)
ip access-list extended CORP-TO-SERVERS
  permit tcp 10.10.10.0 0.0.0.255 10.10.20.0 0.0.0.255 eq 80
  permit tcp 10.10.10.0 0.0.0.255 10.10.20.0 0.0.0.255 eq 443
  permit tcp 10.10.10.0 0.0.0.255 10.10.20.0 0.0.0.255 eq 445
  permit udp 10.10.10.0 0.0.0.255 10.10.20.0 0.0.0.255 eq 53
  permit icmp 10.10.10.0 0.0.0.255 10.10.20.0 0.0.0.255 echo
  deny ip any any log
  exit

! ACL: Guest to Internet only (deny all internal)
ip access-list extended GUEST-OUTBOUND
  deny ip 10.10.40.0 0.0.0.255 10.0.0.0 0.255.255.255
  deny ip 10.10.40.0 0.0.0.255 172.16.0.0 0.15.255.255
  deny ip 10.10.40.0 0.0.0.255 192.168.0.0 0.0.255.255
  permit tcp 10.10.40.0 0.0.0.255 any eq 80
  permit tcp 10.10.40.0 0.0.0.255 any eq 443
  permit udp 10.10.40.0 0.0.0.255 any eq 53
  deny ip any any log
  exit

! ACL: IoT limited access
ip access-list extended IOT-OUTBOUND
  permit tcp 10.10.50.0 0.0.0.255 host 10.10.20.10 eq 443
  permit tcp 10.10.50.0 0.0.0.255 any eq 443
  permit udp 10.10.50.0 0.0.0.255 host 10.10.20.1 eq 53
  deny ip 10.10.50.0 0.0.0.255 10.10.50.0 0.0.0.255 log
  deny ip any any log
  exit

! Apply ACLs to VLAN interfaces
interface Vlan10
  ip access-group CORP-TO-SERVERS out
  exit
interface Vlan40
  ip access-group GUEST-OUTBOUND in
  exit
interface Vlan50
  ip access-group IOT-OUTBOUND in
  exit

Step 5: Configure DHCP and DNS per VLAN

! DHCP pools for each VLAN
ip dhcp pool CORPORATE
  network 10.10.10.0 255.255.255.0
  default-router 10.10.10.1
  dns-server 10.10.20.10
  domain-name corp.example.com
  lease 1
  exit

ip dhcp pool GUEST
  network 10.10.40.0 255.255.255.0
  default-router 10.10.40.1
  dns-server 1.1.1.1 8.8.8.8
  lease 0 4
  exit

ip dhcp pool IOT
  network 10.10.50.0 255.255.255.0
  default-router 10.10.50.1
  dns-server 10.10.20.10
  lease 7
  exit

! Exclude gateway and server IPs from DHCP pools
ip dhcp excluded-address 10.10.10.1 10.10.10.10
ip dhcp excluded-address 10.10.40.1 10.10.40.10
ip dhcp excluded-address 10.10.50.1 10.10.50.10

Step 6: Verify and Test Segmentation

# From a workstation on VLAN 10 (Corporate):
# Should succeed:
ping 10.10.20.10          # Server access
curl https://10.10.20.10  # HTTPS to server

# Should fail:
ping 10.10.40.100         # Guest VLAN - should be blocked
ping 10.10.50.100         # IoT VLAN - should be blocked

# From a device on VLAN 40 (Guest):
# Should succeed:
ping 8.8.8.8              # Internet access
curl https://www.google.com

# Should fail:
ping 10.10.10.1           # Corporate gateway - blocked
ping 10.10.20.10          # Server - blocked

# Verify switch configuration
show vlan brief
show interfaces trunk
show ip arp inspection statistics
show ip dhcp snooping binding
show port-security
show ip access-lists

# Run VLAN hopping tests (from authorized pentest)
# These should all fail if hardening is correct:
# 1. DTP negotiation - should fail (nonegotiate)
# 2. Double tagging - should fail (native VLAN 998)
# 3. ARP spoofing - should fail (DAI enabled)

Key Concepts

Term Definition
VLAN (Virtual LAN) Logical network partition at Layer 2 that groups switch ports into isolated broadcast domains, regardless of physical location
802.1Q Trunking IEEE standard for VLAN tagging that adds a 4-byte header to Ethernet frames, identifying which VLAN a frame belongs to across trunk links
Inter-VLAN Routing Layer 3 forwarding of traffic between VLANs using a router, Layer 3 switch, or firewall with access control lists
Native VLAN VLAN assigned to untagged frames on trunk ports; should be set to an unused VLAN to prevent VLAN hopping attacks
DHCP Snooping Switch feature that validates DHCP messages and builds a binding table of IP-MAC-port mappings, preventing rogue DHCP servers
Port Security Switch feature that limits the number of MAC addresses per port and takes action (shutdown, restrict) when violated

Tools & Systems

  • Cisco Catalyst/Nexus: Enterprise managed switches with comprehensive VLAN, trunking, and security feature support
  • HP Aruba CX: Enterprise switches with REST API management and VLAN segmentation capabilities
  • pfSense/OPNsense: Open-source firewalls for inter-VLAN routing with stateful access control
  • NetBox: Open-source IPAM and DCIM tool for documenting VLAN assignments, IP addressing, and network topology
  • Nmap: Network scanner for verifying segmentation effectiveness by testing reachability across VLAN boundaries

Common Scenarios

Scenario: Implementing PCI-DSS Compliant Network Segmentation for Retail

Context: A retail chain must isolate their payment card processing systems from the general corporate network to meet PCI-DSS requirements. The current flat network has point-of-sale terminals, employee workstations, inventory servers, and guest WiFi on a single VLAN. The environment uses Cisco Catalyst 9300 switches.

Approach:

  1. Design VLAN architecture: POS terminals on VLAN 50 (CDE), corporate on VLAN 10, servers on VLAN 20, guest on VLAN 40
  2. Create VLANs on all access-layer switches and configure access ports by function
  3. Configure trunk links between switches with explicit VLAN allowed lists (no "all" trunks)
  4. Set native VLAN to 998 (unused) on all trunks and disable DTP on every port
  5. Configure ACLs on the Layer 3 switch: CDE VLAN can only reach the payment processor's IP on port 443; no other inter-VLAN traffic to/from CDE
  6. Enable DHCP snooping, DAI, and port security on all access ports
  7. Verify segmentation with penetration testing from each VLAN, confirming CDE is fully isolated

Pitfalls:

  • Leaving DTP enabled on access ports, allowing VLAN hopping to reach the CDE
  • Using VLAN 1 as the native VLAN, enabling double-tagging attacks
  • Not restricting trunk allowed VLANs, carrying all VLANs including CDE to non-essential switches
  • Creating ACLs that allow "any" source to reach CDE servers instead of specific POS terminal IPs

Output Format

## Network Segmentation Implementation Report

**Network**: Retail Store #42
**Switch Platform**: Cisco Catalyst 9300
**VLANs Configured**: 8

### VLAN Summary

| VLAN ID | Name | Subnet | Ports | Purpose |
|---------|------|--------|-------|---------|
| 10 | CORPORATE | 10.10.10.0/24 | Gi1/0/1-24 | Employee workstations |
| 20 | SERVERS | 10.10.20.0/24 | Gi1/0/25-36 | Internal servers |
| 30 | DMZ | 10.10.30.0/24 | Gi2/0/1-4 | Internet-facing |
| 40 | GUEST | 10.10.40.0/24 | WiFi AP trunk | Guest WiFi |
| 50 | CDE | 10.10.50.0/24 | Gi2/0/5-12 | POS terminals |
| 100 | MGMT | 10.10.100.0/24 | Gi1/0/48 | Switch management |
| 998 | NATIVE | N/A | Trunks only | Unused native |
| 999 | QUARANTINE | 10.10.99.0/24 | Unused ports | Isolation |

### Security Hardening Status

| Control | Status |
|---------|--------|
| DTP Disabled (nonegotiate) | All ports |
| Native VLAN (998) | All trunks |
| DHCP Snooping | VLANs 10,20,40,50 |
| Dynamic ARP Inspection | VLANs 10,20,40,50 |
| Port Security | Access ports |
| BPDU Guard | Access ports |
| Unused Ports Shutdown | 10 ports in VLAN 999 |
| VTP Transparent Mode | Enabled |

04 同仓库更多 Skills

mukul975
mukul975/Anthropic-Cybersecurity-Skills

SLSA 构建来源验证

verifying-build-provenance-with-slsa-sigstore

使用 Sigstore 的 cosign(verify、verify-attestation、verify-blob-attestation)和 slsa-verifier(verify-artifact)验证工件签名和 SLSA 来源(provenance),强制校验 keyless OIDC 构建者身份和源仓库是否符合 SLSA Build 级别。适用于 CI/CD 中部署工件前、消费第三方证明时、建立 SLSA Build L3 管道,或在事件响应或准入控制期间确认来源的场景。

安全工程师软件供应链安全
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

TPM 测量启动验证

validating-tpm-measured-boot-attestation

使用 tpm2-tools 验证 TPM 2.0 测量启动(measured boot)的完整性和远程证明:读取 PCR(tpm2_pcrread)、重放启动事件日志、生成并检查签名报价(tpm2_quote/tpm2_checkquote),以及将机密封印(seal)到 PCR 策略。适用于确认系统已启动可信固件/内核以实现零信任(Zero Trust)设备状态、通过 PCR 漂移检测启动链篡改,或构建黄金值基线用于机群(fleet)证明。

安全工程师终端安全加固
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

备份完整性验证

validating-backup-integrity-for-recovery

通过加密哈希验证、自动化恢复测试、损坏检测和可恢复性检查来验证备份完整性,确认备份对于灾难恢复和勒索软件响应是可靠的。适用于在依赖备份进行恢复之前、构建备份后验证管道、审计备份基础设施以满足合规要求,或检查不可变/air-gapped(气隙)备份是否存在静默损坏或篡改的场景。

SRE 工程师备份与灾难恢复
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

KAPE Windows 取证收集

triaging-windows-with-kape

运行 KAPE(Kroll Artifact Parser and Extractor),通过 Targets 收集目标取证工件(注册表配置单元、$MFT、事件日志、prefetch、浏览器数据),并使用封装 Eric Zimmerman 的 EZ Tools(PECmd、MFTECmd、RECmd)的 Modules 进行解析。适用于事件遏制/分诊早期阶段——此时完整磁盘镜像不切实际,但需要快速获得可采信、可解析的 Windows 工件集,包括大规模远程收集。

安全工程师数字取证与电子证据分析
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

SSVC 漏洞优先级分诊

triaging-vulnerabilities-with-ssvc-framework

使用 CISA 的 Stakeholder-Specific Vulnerability Categorization(SSVC,利益相关方特定漏洞分类)决策树对漏洞进行分诊和优先级排序,权衡利用状态(通过 CISA KEV 目录和 FIRST EPSS API)、技术影响、自动化程度和任务普遍性,输出 Track/Track*/Attend/Act 决策。适用于对漏洞扫描结果(OpenVAS、Nessus、Qualys)进行优先级排序以制定修复计划,而不局限于原始 CVSS 分数的场景。

安全工程师安全公告与漏洞管理
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

安全事件初步分诊

triaging-security-incident

使用 NIST SP 800-61r3 和 SANS PICERL 框架对安全事件进行初步分诊,分类事件类型、按业务影响分配优先级,并路由到相应的响应团队。适用于 SIEM/EDR 告警需要人工分类、并发告警必须确定优先级,或用户报告或威胁情报 IOC 匹配需要初步事件分类的场景。

安全工程师安全事件响应与威胁狩猎
★ 3.6w